DOI QR코드

DOI QR Code

Reliability of static balance abilities measure using a smartphone's acceleration sensor

스마트폰의 가속도 센서를 이용한 정적균형능력 측정의 신뢰도 연구

  • Han, Seul-Ki (Department of Physical Therapy, Youngdong University) ;
  • Lee, In-Hak (Department of Physical Therapy, Daejeon Health Sciences College) ;
  • Park, Nu-Ri (Seochocham Hospital)
  • Received : 2016.03.15
  • Accepted : 2016.06.02
  • Published : 2016.06.30

Abstract

The purpose of this study is to investigate the reliability of static balance measurements using a smartphone. Thirty subjects were selected among university students who had no fractures, history of operation, or inflammatory arthritis, and they had not started regular exercise during the past three months. The smartphone used in this study was a Galaxy S5LTE (SM-G900F, Samsung, Korea, 2014), and the application was a Sensor Kinetics Pro (Ver. 2.1.2, INNOVENTIONS Inc., US, 2015). Static balance ability was measured three times at one-day intervals between tests and retests. The first and second measurements used the same process. Analysis was done using the Wilcoxon signed rank test and intraclass correlation coefficient (ICC (2,1)). The results were as follows. With eyes opened, there was no significant difference (p>0.05), a high volume of correlation (r>0.75, p<0.05), and very high reliability (ICC>0.80) between the first measurement and second measurement. With eyes closed, there was also no significant difference (p>0.05), a high volume of correlation (r>0.75, p<0.05), and very high reliability (ICC>0.80) between the measurements. The results show that the smartphone is likely accurate for measuring static balance. This study will look forward to being the only basis for measuring future application development and the ability to balance.

본 연구는 스마트폰의 가속도 센서를 이용하여 정적균형능력을 측정하는데 있어 신뢰도를 알아보고자 실시하였다. 본 연구의 연구대상자는 최근 3개월 이내에 골절, 수술, 염증성 관절염이 없고 정기적인 운동을 시작하지 않은 Y대학교의 학생 30명을 대상으로 하였다. 본 연구에 사용된 스마트폰은 갤럭시S5LTE (SM-G900F, Samsung, Korea, 2014)였고 어플리케이션은 Sensor Kinetics pro (Ver.2.1.2, INNOVENTIONS Inc, US, 2015)를 사용하였다. 정적균형능력은 1회당 3번씩 측정하였으며 하루 간격으로 검사-재검사로 시행되었다. 1차 측정과 2차 측정은 동일하게 진행되었다. 본 연구의 분석은 Wilcoxon 부호순위검정, 급내상관계수(ICC(2,1))를 사용하였다. 본 연구의 연구결과는 다음과 같았다. 눈을 뜬 상태에서 1차 측정과 2차 측정 간에 유의한 차이가 없었고(p>0.05) 강한 양의 상관관계를 보였으며(r>0.75, p<0.05) 매우 높은 일치도(ICC>0.80)를 보였다. 눈을 감은 상태에서 1차 측정과 2차 측정 간에 유의한 차이가 없었고(p>0.05) 강한 양의 상관관계를 보였으며(r>0.75, p<0.05) 매우 높은 일치도(ICC>0.80)를 보였다. 본 연구를 통해 스마트폰은 정적균형능력 측정에 있어 가능성이 있다는 사실을 알 수 있었으며 본 연구가 향후 균형능력측정 전용 어플리케이션 개발에 기초자료가 되기를 기대해본다.

Keywords

References

  1. S. G. Ji, H. G. Cha, D. G. Lee, "The Effects of Trunk Pattern Training in Proprioceptive Neuromuscular Facilitation on Muscle Activity of Lower extremity and Static Balance in Stroke Patients", JKAIS, 14(11), pp. 5730-5736, 2013. DOI: http://dx.doi.org/10.5762/kais.2013.14.11.5730
  2. Jarnlo, G-B, "Functional balance tests related to falls among elderly people living in the community", European Journal of Geriatrics, 5, pp. 7-14, 2003.
  3. K. H. Jang, K. Y. Kim, "Effect of Intensive Trunk-Pelvic Stabilization Training Using Sling on Muscle Activity and Balance in Hemiplegia" JKAIS, 12(3), pp. 1244-1252, 2011. DOI: http://dx.doi.org/10.5762/kais.2011.12.3.1244
  4. H. J. Choi, D. Y. Lee, Y. H. Kim, "The Effect of Balance and Function in Children with Spastic Cerebral Palsy using Motor Learning training with Treadmill" JKAIS, 14(2), pp. 804-810, 2013. DOI: http://dx.doi.org/10.5762/kais.2013.14.2.804
  5. C. W. Lee, S. G. Kim, S. S. Na, "The effects of hippotherapy and a horse riding simulator on the balance of children with cerebral palsy", J Phys Ther Sci, 26(3), pp. 423-425, 2014. DOI: http://dx.doi.org/10.1589/jpts.26.423
  6. M. C. Kim, S. K. Han, H. J. Oh, "A Comparison of the Effects of the Muscle Activity and Balance Ability by a Kind of Ground During Blance Exercise", JKAIS, 13(10), pp. 4598-4603, 2012. DOI: http://dx.doi.org/10.5762/kais.2012.13.10.4598
  7. H. S. Cho, H. G. Cha. "Effects of Trunk Pattern Exercise in Proprioceptive Neuromuscular Facilitation Integrated Transcranial Direct Current Stimulation on Function of Lower extremity in Stroke Patients", JKAIS, 15(11), pp. 6767-6773, 2014. DOI: http://dx.doi.org/10.5762/kais.2014.15.11.6767
  8. W. D. Chang, W. Y. Chang, C. L. Lee C. Y. Feng, "Validity and reliability of wii fit balance board for the assessment of balance of healthy young adults and the elderly", J Phys Ther Sci, 25(10), pp. 1251-1253, 2013. DOI: http://dx.doi.org/10.1589/jpts.25.1251
  9. Blum L, Korner-Bitensky N, "Usefulness of the Berg Balance Scale in stroke rehabilitation: a systematic review", Phys Ther, 88(5), pp. 559-66, 2008. DOI: http://dx.doi.org/10.2522/ptj.20070205
  10. H. K. Yang, H. S. Yong, "Real-Time Physical Activity Recognition Using Tri-axis Accelerometer of Smart Phone", JOURNAL OF KOREA MULTIMEDIA SOCIETY, 17(4), pp. 506-513, 2014. DOI: http://dx.doi.org/10.9717/kmms.2014.17.4.506
  11. J. Y. Lim, T. H. Kim, J. S. Lee, "Reliability of measuring the passive range of shoulder horizontal adduction using a smartphone in the supine versus the side-lying position", J Phys Ther Sci, 27(10), pp. 3119-3122, 2015. DOI: http://dx.doi.org/10.1589/jpts.27.3119
  12. Matsumura K, Yamakoshi T, "iPhysioMeter: a new approach for measuring heart rate and normalized pulse volume using only a smartphone" Behav Res Methods, 45(4), pp. 1272-1278, 2013. DOI: http://dx.doi.org/10.3758/s13428-012-0312-z
  13. P. H. Jung, S. W. Lee, C. K. Song, D. Y. Kim, "Counting Walk-steps and Detection of Phone's Orientation/Position Using Inertial Sensors of Smartphones", Journal of KIISE: Computing Practices and Letters, 13(1), pp. 46-50, 2013.
  14. J. H. Lee, K. J. Lee, Y. H. Kim, S. H. Lee, S. W. Park, "Development of Gait Analysis Algorithm for Hemiplegic Patients based on Accelerometry", System and Control, 41(4), pp. 55-62, 2004.
  15. C. W. Won, Y. G. Rho, S. Y. Kim, B. R. Cho, Y. S. Lee, "The validity and reliability of Korean activities of daily living(K-ADL) scale", J Korean Geriatr Soc, 6(2), pp. 98-106, 2002.
  16. H. J. Ha, K. H. Cho W. H. Lee, "Reliability of the good balance system((R)) for postural sway measurement in poststroke patients", J Phys Ther Sci, 26(1), pp. 121-124, 2014. DOI: http://dx.doi.org/10.1589/jpts.26.121
  17. Arifin N, Abu Osman NA, Wan Abas WA, "Intrarater test-retest reliability of static and dynamic stability indexes measurement using the Biodex Stability System during unilateral stance", J Appl Biomech, 30(2), pp. 300-304, 2014. DOI: http://dx.doi.org/10.1123/jab.2013-0130
  18. Patterson JA, Amick RZ, Thummar T, Rogers ME, "Validation of measures from the smartphone sway balance application: a pilot study", Int J Sports Phys Ther, 9(2), pp. 135-139, 2014.
  19. Galan-Mercant A, Baron-Lopez FJ, Labajos-Manzanares MT, Cuesta-Vargas AI, "Reliability and criterion-related validity with a smartphone used in timed-up-and-go test", Biomed Eng Online, 2(13), pp. 156, 2014. DOI: http://dx.doi.org/10.1186/1475-925X-13-156
  20. S. K. Han, M. C. Kim, C. S. An. "Comparison of effects of a proprioceptive exercise program in water and on land the balance of chronic stroke patients", J Phys Ther Sci, 25(10), pp. 1219-1222, 2013. DOI: http://dx.doi.org/10.1589/jpts.25.1219

Cited by

  1. Validation of Joint Position Sense of Dorsi-Plantar Flexion of Ankle Measurements Using a Smartphone vol.23, pp.3, 2017, https://doi.org/10.4258/hir.2017.23.3.183
  2. Smartphone Based Standing Balance Evaluation Using Frequency Domain Analysis of Acceleration vol.25, pp.3, 2018, https://doi.org/10.12674/ptk.2018.25.3.027