The Reliability of Flexor Hallucis Longus Stretch Test in Subjects with Asymmetric Hallux Valgus Angles

  • Koh, Eun-Kyung (Department of Physical Therapy, Masan University) ;
  • Jung, Do-Young (Department of Physical Therapy, Kinesiopathologic Science Institute, Joongbu University)
  • Received : 2016.03.22
  • Accepted : 2016.04.23
  • Published : 2016.04.30

Abstract

Purpose: The flexor hallucis longus stretch test can determine the shortness of the flexor hallucis longus muscle by measuring the angle of extension in the first metatarsophalangeal (MTP) joint at maximum ankle dorsiflexion. Less than 30 degrees of the first MTP joint at the maximal ankle dorsiflexion indicates shortness of the flexor hallucis longus muscle. The purpose of this study was to examine the intra- and inter-reliability of the flexor hallucis longus stretch test in subjects with asymmetric hallux valgus (HV) angles. Methods: Sixteen subjects with asymmetric HV angles participated in this study. In sitting position, dorsiflexion angles of the first MTP joint were measured with maximum ankle dorsiflexion on each side. ICC (3,1) and ICC (3,k) models were used, respectively, to assess the intra-reliability and inter-reliability of the flexor hallucis longus stretch test. The paired-t test was used to compare the dorsiflexion angle of the first MTP joint on the side with the smaller HV angle with that of the side with the larger HV angle. Results: The results of the study showed that both intra- and inter-reliability were more than 0.95 of the coefficient. Dorsiflexion angle of the first MTP joint was higher on the side with the smaller HV angle. Conclusion: Use of the flexor hallucis longus stretch test is acceptable in clinical settings because both intra- and inter-reliability were high in subjects with asymmetric HV angles. In addition, shortness of the flexor hallucis longus muscle is associated with HV angle. This study provides useful information for use in management of HV deformity.

Keywords

References

  1. Hopson MM, McPoil TG, Comwall MW. Motion of the first metatarsophalangeal joint. Reliability and validity of four measurement techniques. J Am Podiatr Med Assoc. 1995;85(4):198-204. https://doi.org/10.7547/87507315-85-4-198
  2. Aquino A, Payne C. Function of the windlass mechanism in excessively pronated feet. J Am Podiatr Med Assoc. 2001; 91(5):245-50. https://doi.org/10.7547/87507315-91-5-245
  3. Nawoczenski DA, Baumhauer JF, Umberqer BR. Relationship between clinical measurements and motion of the first metatarsophalangeal joint during gait. J Bone Joint Surg Am. 1999;81(3):370-6. https://doi.org/10.2106/00004623-199903000-00009
  4. Kappel-Bargas A, Woolf RD, Cornwall MW et al. The windlass mechanism during normal walking and passive first metatarsalphalangeal joint extension. Clin Biomech (Bristol, Avon). 1998;13(3):190-4. https://doi.org/10.1016/S0268-0033(97)00038-7
  5. Sharmann S. Movement system impairment syndromes of the extremities, cervical and thoracic spines. St. Louis, Mosby. 2010:445-6.
  6. Yun SJ, Kang MH, Kim MH. Difference of position change of sesamoid bones during active abduction exercise of great toe in subjects with hallux valgus. J Kor Phys Ther. 2015;27(2):85-8. https://doi.org/10.18857/jkpt.2015.27.2.85
  7. Michelson J, Dunn L. Tenosynovitis of the flexor hallucis longus: a clinical study of the spectrum of presentation and treatment. Foot Ankle Int. 2005;26(4):291-303. https://doi.org/10.1177/107110070502600405
  8. Jones AM, Curran SA. Intrarater and interrater reliability of first metatarsophalangeal joint dorsiflexion: Goniometry versus visual estimation. J Am Podiatr Med Assoc. 2012;102(4): 290-8. https://doi.org/10.7547/1020290
  9. Otter SJ, Aqalliu B, Baer N et al. The reliability of a smartphone goniometer application compared with a traditional goniometer for measuring first metatarsophalangeal joint dorsiflexion. J Foot Ankle Res. 2015;8:30. https://doi.org/10.1186/s13047-015-0088-3
  10. Choi GH, Park KY, Byun SJ, et al. A study on angular correlation between hallux valgus and 1st MPJ dorsi-flexion according to work type and age of woman. J Kor Phys Ther. 2011;23(5):57-63. https://doi.org/10.1589/jpts.23.57
  11. Ferris L, Sharkey NA, Smith TS et al. Influence of extrinsic plantar flexors on forefoot loading during heel rise. Foot Ankle Int. 1995;16(8): 464-73. https://doi.org/10.1177/107110079501600802
  12. Thordarson DB, Schmotzer H, Chon J et al. Dynamic support of the human longitudinal arch. A biomechanical evaluation. Clin Orthop Relat Res. 1995;316:165-72.
  13. Hintermann B, Nigg BM, Sommer C. Foot movement and tendon excursion: an in vitro study. Foot Ankle Int. 1994;15(7):386-95. https://doi.org/10.1177/107110079401500708
  14. Klein P, Mattys S, Rooze M. Moment arm length variations of selected muscles acting on talocrural and subtalar joints during movement: An in vitro study. J Biomech. 1996;29(1):21-30. https://doi.org/10.1016/0021-9290(95)00025-9
  15. Jacob HA. Forces acting in the forefoot during normal gait--an estimate. Clin Biomech (Bristol, Avon). 2001;16(9):783-92. https://doi.org/10.1016/S0268-0033(01)00070-5

Cited by

  1. Comparisons of Test-Retest Reliability of Strength Measurement of Gluteus Medius Strength between Break and Make Test in Subjects with Pelvic Drop vol.31, pp.3, 2019, https://doi.org/10.18857/jkpt.2019.31.3.147