Acknowledgement
Supported by : Ministry of Health and Welfare
References
- Held PJ, Port FK, Wolfe RA, et al. The dose of hemodialysis and patient mortality. Kidney Int 1996;50:550-556. https://doi.org/10.1038/ki.1996.348
- Mandolfo S, Borlandelli S, Ravani P, Imbasciati E. How to improve dialysis adequacy in patients with vascular access problems. J Vasc Access 2006;7:53-59. https://doi.org/10.1177/112972980600700203
- Jadoul M, Thumma J, Fuller DS, et al. Modifiable practices associated with sudden death among hemodialysis patients in the Dialysis Outcomes and Practice Patterns Study. Clin J Am Soc Nephrol 2012;7:765-774. https://doi.org/10.2215/CJN.08850811
- Singh S, Choi P, Power A, et al. Ten-year patient survival on maintenance haemodialysis: association with treatment time and dialysis dose. J Nephrol 2013;26:763-770. https://doi.org/10.5301/jn.5000234
- Hassell DR, van der Sande FM, Kooman JP, Tordoir JP, Leunissen KM. Optimizing dialysis dose by increasing blood flow rate in patients with reduced vascular-access flow rate. Am J Kidney Dis 2001;38:948-955. https://doi.org/10.1053/ajkd.2001.28580
- Kimata N, Karaboyas A, Bieber BA, et al. Gender, low Kt/V, and mortality in Japanese hemodialysis patients: opportunities for improvement through modifiable practices. Hemodial Int 2014;18:596-606. https://doi.org/10.1111/hdi.12142
- Tentori F, Zhang J, Li Y, et al. Longer dialysis session length is associated with better intermediate outcomes and survival among patients on in-center three times per week hemodialysis: results from the Dialysis Outcomes and Practice Patterns Study (DOPPS). Nephrol Dial Transplant 2012;27:4180-4188. https://doi.org/10.1093/ndt/gfs021
- Pisoni RL, Arrington CJ, Albert JM, et al. Facility hemodialysis vascular access use and mortality in countries participating in DOPPS: an instrumental variable analysis. Am J Kidney Dis 2009;53:475-491. https://doi.org/10.1053/j.ajkd.2008.10.043
- Arbor Research Collaborative for Health. DOPPS practice monitor [Internet]. Ann Arbor (MI): Arbor Research Collaborative for Health, c2015 [cited 2015 Dec 16]. Available from: http://www.dopps.org/DPM/Default.aspx.
- Bloembergen WE, Stannard DC, Port FK, et al. Relationship of dose of hemodialysis and cause-specific mortality. Kidney Int 1996;50:557-565. https://doi.org/10.1038/ki.1996.349
- Borzou SR, Gholyaf M, Zandiha M, Amini R, Goodarzi MT, Torkaman B. The effect of increasing blood flow rate on dialysis adequacy in hemodialysis patients. Saudi J Kidney Dis Transpl 2009;20:639-642.
- Kim YO, Song WJ, Yoon SA, et al. The effect of increasing blood flow rate on dialysis adequacy in hemodialysis patients with low Kt/V. Hemodial Int 2004;8:85.
- Eknoyan G, Beck GJ, Cheung AK, et al. Effect of dialysis dose and membrane flux in maintenance hemodialysis. N Engl J Med 2002;347:2010-2019. https://doi.org/10.1056/NEJMoa021583
- Gutzwiller JP, Schneditz D, Huber AR, Schindler C, Garbani E, Zehnder CE. Increasing blood flow increases kt/V(urea) and potassium removal but fails to improve phosphate removal. Clin Nephrol 2003;59:130-136. https://doi.org/10.5414/CNP59130
- Vanholder R, Glorieux G, Eloot S. Once upon a time in dialysis: the last days of Kt/V? Kidney Int 2015;88:460-465. https://doi.org/10.1038/ki.2015.155
Cited by
- CD62P and P10 as predictive markers for assessing the efficacy of hemodialysis in treating end‐stage renal disease vol.33, pp.2, 2016, https://doi.org/10.1002/jcla.22662
- Assessment of hemodialysis clinical practices using polyaryl ether sulfone-polyvinylpyrrolidone (PAES: PVP) clinical membrane: Modeling of in vitro fibrinogen adsorption, in situ synchrotron-based ima vol.259, pp.None, 2016, https://doi.org/10.1016/j.seppur.2020.118136
- Improvement of clinical outcomes in dialysis: No convincing superiority in dialysis efficacy using hemodiafiltration vs high‐flux hemodialysis vol.25, pp.4, 2016, https://doi.org/10.1111/1744-9987.13492
- Novel Cellulose Acetate-Based Monophasic Hybrid Membranes for Improved Blood Purification Devices: Characterization under Dynamic Conditions vol.11, pp.11, 2016, https://doi.org/10.3390/membranes11110825