DOI QR코드

DOI QR Code

두경부 PET/CT검사 시 인공음영 감소에 관한 연구 (환자 피폭선량 경감)

The Study of Decrease Artifact when Scanning Head and Neck PET/CT(Decrease Radiation Dose of Patient)

  • 김기진 (건양대학교병원 영상의학과) ;
  • 김가중 (극동대학교 방사선학과) ;
  • 유세종 (건양대학교병원 영상의학과) ;
  • 김정호 (건양대학교병원 방사선종양학과)
  • Kim, Ki-Jin (Dept. of Diagnostic Radiology, Konyang University Hospital) ;
  • Kim, Gha-Jung (Department of Radiological Science, Far East University) ;
  • Yoo, Se-Jong (Dept. of Diagnostic Radiology, Konyang University Hospital) ;
  • Kim, Jeong-Ho (Dept. of Radiation Oncology, Konyang University Hospital)
  • 투고 : 2015.10.16
  • 심사 : 2016.03.21
  • 발행 : 2016.03.31

초록

Beam hardening artifact can be caused by metal material when performing PET exam. Therefore, we studied a solution decreasing artifact caused by metallic dental implant. The higher voltage, the lesser artifact in CT exam. But Higher voltage dosen't affect PET exam. The thicker silicon the lesser artifact in CT and PET exam. Both methods make less artifact in CT and PET exam. But considering safety of patient, the way of using silicon is better.

키워드

참고문헌

  1. Wahl, R.L. (1999),"To AC or not to AC : that is the question", J Nucl Med, 40:2046-2053.
  2. Park, S.Y. Bae, J.M. Kim S.W. et al.,(2009), "Effectiveness of Positron Emission Tomography in the Pre-operative Staging of Gastric Cancer, J Korean Gastric Cancer Assoc, 9(3):110-116. https://doi.org/10.5230/jkgca.2009.9.3.110
  3. Goerres, G.W. Ziegler, S.I. Gurger C. et al.,(2003), "Artifacts at PET and PET/CT acused by metallic hip prosthetic material", Radiology, 226:577-584. https://doi.org/10.1148/radiol.2262012141
  4. Claude Nahmias, Catherine Lemmens, David Faul et al,.(2008), "Dose Reducing CT Artifacts from Dental Implants Influence the PET Interpretation in PET/CT Studies of Oral Cancer and Head and Neck Cancer?." 49:1047-1052. https://doi.org/10.2967/jnumed.107.049858
  5. Kim, K.J. Bea, S.B. Han, S.H. et al.,(2012), "The Effect of Metal Dental Implant on Positron Emission Tomography Comuted Tomography Image." SDPM, 10(2):243-247.
  6. Kim, H.J.(2010), "Study for Improving Image Quality by Reducing High Contrast(Metallic) Artifact in Head & Neck CT Scan." Graduate School of Soonchunhyang University
  7. Textbook of Computed Tomography, CHUNGU, 13-16, 26-36, 64, 76.
  8. Kang, S.K. Cho, B.C. Park, H.C. et al,.(2004), "The Effects of the CT Voltages on the Dose Calculated by Commercial RTP System." Korean Journal of Medical Physics, 15(1):23-29.
  9. Sigal-Cinqualbre A.B. (2004), "Low Kilovoltage Multi-Detector Row Chest CT in Adults:Fesibility and Effect on Image Quality and Iodine Dose", Radiology, 231(1):169-174. https://doi.org/10.1148/radiol.2311030191
  10. Dischoff B,(2009), "Impact of a Reduced Tube Voltage on CT Angiography and Radiation Dose:Results of the PROTECTION I Study", JACC Cardiovasc Imaging, 2(8):940-946. https://doi.org/10.1016/j.jcmg.2009.02.015