DOI QR코드

DOI QR Code

A Study on the Flash Point and Spontaneous Ignition Determination of Diethylene Glycol

  • Kim, Jung-Hun (Graduated school of Fire Protection Engineering, Pukyong National University) ;
  • Choi, Jae-Wook (Department of Fire Protection Engineering, Pukyong National University)
  • Received : 2016.01.01
  • Accepted : 2016.03.25
  • Published : 2016.04.30

Abstract

This study investigates the main factors of fire prevention, such as spontaneous ignition and flash point, while using Diehylene Glycol (DEG) as the antifreeze for automobile and industrial machines. Our results show the flash point of $142^{\circ}C$ and the minimum ignition temperature of $388^{\circ}C$ in the range of $130{\mu}{\ell}{\sim}150{\mu}{\ell}$. By increasing temperature to ignite in 1 second, an instantaneous ignition temperature of the sample is $569^{\circ}C$ in the sample amount of $140{\mu}{\ell}$.

Keywords

References

  1. J.W. Choi, Y.S. Mok and S.Y. Kim, A Study on Autoignition characteristics of 1-Heptene, 2-Heptene and 3-Heptene. Journal of Korean Society of Safety, Vol.5, pp. 17-23, 1990.
  2. J.W. Choi, A Study on the Spontaneous Ignition Characteristics and lgnition Temperature Estimation of Activated Carbon. Journal of Korean Society of Safety, Vol.9, pp. 74-81, 1994.
  3. T.Y . Kim: Study on the Flash Point and Spontaneous Ignition Determination of 2-Propanol and O-xylene Mixtures, Masters, Dept. of Safety Engineering, Pukyong National University, Korea, pp. 1-2, 2012.
  4. J.M. Kuchta, A. barkowak and M.G. Zabetakis, Hot Surface Ignition Temperatures of Hydrocarbon Fuel Vapor-Air Mixtures, j. of chemical and Engineering Data, Vol.10, pp. 282-288, 1965. https://doi.org/10.1021/je60026a023
  5. Chemicalland, http://www.chemicalland21.com/petrochemical/DEG.html, 2015/08/25..
  6. D.J. Kim: Study on Ignition Characteristics of Diesel and Kerosene to sell at Gas Station, Masters, Dept. of Safety Engineering, Pukyong National University, Korea, pp.8-10, 2012.
  7. KOSHA, MSDS, http://msds.kosha.or.kr/kcic/msdsd etail.do, 2015/09/28.
  8. I.S. Lee, J.W. Choi, D.G. Jung, W.S. Lim and C.W. Min, A Study of the Spontaneous Ignition and the Flash Point of MEK-PO. Journal of Korean Institute of Fire Science & Engineering, Vol. 11, pp. 25-29, 2004.
  9. ASTM, Test Method D2155-63T Standard Test Method for Autoignition Temperature of Liquid Chemicals, American Society for Testing Materials, Philadelpia, PA, 1994.
  10. J.W. Choi, Y. S. Mok, I.G. Choi, S.H. Jeon, W.S. Lim and C.W. Min, A Study on the Spontaneous Ignition of Gasoline and Additive of Fuel. Journal of Fire Science and Engineering, Vol. 20, pp. 2-4, 2006.