DOI QR코드

DOI QR Code

A Fundamental Study of Hybrid Combustion System Applying Exhaust Gas Recirculation

배기가스 재순환을 적용한 하이브리드 연소시스템에 대한 기초 연구

  • Received : 2015.10.22
  • Accepted : 2015.12.24
  • Published : 2016.03.31

Abstract

In this study confirmed the reduction effect of pollutant by applying Fi-EGR and FPI-EGR to hybrid combustion system realizing premixed flame and non-premxied flame at once. The results showed that NOx emission index decreased significantly in case of adopting EGR. Additionally, the hybrid combustion system with EGR resulted in a better performance compared to usual non-premixed combustion system such that it can reduce $NO_x$ emission at equivalent EGR ratios. Especially, in the case of 25% of FI-EGR ratio at hybrid combustion system that the ratio of non-premixed and premixed is 50 : 50, NOx emission index reduction rate was about 59% compared to $NO_x$ emission of non-premixed combustion system without EGR and in the case of 15% of FPI-EGR ratio at hybrid combustion system that the ratio of non-premixed and premixed is 70 : 30, $NO_x$ emission index reduction rate was about 48% compared to $NO_x$ emission of hybrid combustion system without EGR.

본 연구에서는 예혼합 화염과 비예혼합 화염을 동시에 구현하는 하이브리드 연소시스템에 배기가스 재순환 방법(FI-EGR and FPI-EGR)을 적용하여 공해물질 저감 효과를 확인하였다. 그 결과, 배기가스 재순환을 적용한 경우 상당량의 NOx 배출지수가 감소하는 것을 확인 할 수 있었으며, 추가적으로 배기가스 재순환을 적용한 하이브리드 연소시스템의 배출성능이 동일한 배기가스 재순환율을 가지는 비예혼합 화염의 배출성능보다 우수함을 확인하였다. 특히, 비예혼합 화염과 예혼합 화염의 비율이 50: 50인 하이브리드 연소시스템의 연료 측에 25% 까지 배기가스를 재순환 시킬 경우(FI-EGR), 배기가스 재순환을 적용하지 않은 비예혼합 화염에 비해 NOx 배출지수가 59% 저감되는 것을 확인하였으며, 혼합비율이 70:30인 하이브리드 연소시스템의 예혼합기와 연료측에 15%까지 배기가스를 재순환 시킬 경우(FPI-EGR), 배기가스를 재순환하지 않은 하이브리드 화염에 비해 NOx 배출지수가 48% 저감되는 것을 확인하였다.

Keywords

References

  1. G. Aurlien, R.V. Elena and W. Oliver, Devleopment of European Ecolabel Criteria for Hydronic Heaters, European commission: Institute for Prospective technological studies, 2013.
  2. SCAQMD, Rule 1146.2, Emissions of oxides of nitrogen from large water heaters and small boilers and process heaters.
  3. Korea environment Corporation, "Low NOx burner approval test and performance verification test," web address: http://www.keco.or.kr/en/core/prevention_vapor/contentsid/2020/index.do.
  4. M. Blume, J.P. Bohn, A. Goanta, H. Spliethoff, Reduction of the flue gas recirculation rate in oxycoal processes by means of non-stoichiometric burner operation, Energy, 2012, 45, 117-124. https://doi.org/10.1016/j.energy.2012.02.077
  5. M. Bae, K. Jung and Y. Cho, A Study on the Effect of Recirculated Exhaust Gas upon Exhaust Emissions of Boiler with a FGR System, Trans. Korean Soc. Mech. Eng. B, 2007, 31, 405-415. https://doi.org/10.3795/KSME-B.2007.31.5.405
  6. B. Yu, S.M. Kum, C.E Lee, S. Lee, Study on the combustion characteristics of a premixed combustion system with exhaust gas recirculation, Energy, 2013, 61, 345-353. https://doi.org/10.1016/j.energy.2013.08.057
  7. B. Yu, S.M. Kum, C.E. Lee, S. Lee, Effects of exhaust gas recirculation on the thermal efficiency and combustion characteristics for premixed combustion system, Energy, 2013, 49, 375-383. https://doi.org/10.1016/j.energy.2012.10.057
  8. B. Yu, J. Kim, C.E. Lee, The effects of Exhaust Gas Recirculation on Non-premixed Combustion System, J. Korean Soc. Combust., 2014, 19(3), 26-33. https://doi.org/10.15231/jksc.2014.19.3.026
  9. G. Cho, G. Moon, D. Jeong, C. Bae, Effects of internal exhaust gas recirculation on controlled auto-ignition in a methane engine combustion, Fuel, 2009, 88(6), 1042-1048. https://doi.org/10.1016/j.fuel.2008.10.042
  10. S.B. Han and S.M. Kim, A Study on Exhaust Gas Recirculation of Homogeneous Charge Compression Ignition Engine, Journal of Energy Engineering, 2009, 18(3), 163-168.
  11. S.R. Turns, An Introduction to Combustion., Mc-Graw-Hill, Singapore, 2000, 553-555.