Abstract
In this paper, we studied about the radiated emission of EFT(Electrical Fast Transient)/Burst signal, referenced IEC-61000-4-4 of the international EMC standard and its effect on EUT(Equipment Under the Test) when EFT/Burst signal (Conducted noise) induced on a power cable to EUT. Firstly, we set up test sample by the standard and +4 kV standard signal is induced by EFT/Burst signal generator with 1 m length power cable for 1 minute. Consequently, we found not only induced EFT/Burst signal along power line, but also directly radiated emission signal from EFT/Burst signal generator (Radiated emission noise of EFT/Burst). The radiated emission signal of EFT/Burst was 30 dB which is higher than limit of CISPR 22 which is international EMC standard. Moreover, we measured the electric field strength by changing distance from maximum radiated emission point to electric field strength tester. As a result, this electric field strength was 23 V/m which is higher than international EMC standard test level(CISPR 24). Therefore, it was confirmed that the probability of malfunction may be high when radiated emission of EFT/Burst noise exists near the EUT.
본 논문에서는 전자파적합성 국제 규격인 IEC 61000-4-4에서 규정하고 있는 전기적으로 빠른 과도현상/버스트(EFT/Burst) 신호가 전원선을 따라 시험대상품에 인가될 때, 인가신호에 기인하여 방사되는 불요전자파와 그 신호가 피시험품에 미치는 영향에 대해 연구하였다. 먼저 국제규격에 규정된 시험 배치방법에 따라 시험 샘플을 설치하고, 검증된 EFT/Burst 발생기로 1분 동안 +4 kV의 규정된 신호를 길이 1 m인 전원선을 통해 시험 샘플에 인가하였다. 그 결과, 전원선을 통해 인가되는 전도성 EFT/Burst 내성 신호 외 버스트 발생기 및 전원선에서 직접 공기 중으로 방출되는 방사성 신호(EFT/Burst 노이즈)가 검출되었고, 국제 공인시험 규격으로 이 신호를 측정한 결과, 규제 레벨보다 30 dB 이상 높았다. 또한, EFT/Burst 방사성 신호의 최대 방사 지점과 시험품의 이격 거리에 따른 전계강도를 측정한 결과, 방사내성 국제 규격치보다 최대 23 V/m 이상 강한 전계강도가 검출되었다. 이는 EFT/Burst 방사성 노이즈가 직접적으로 제품에 인가되어 오동작을 유발할 가능성이 대단히 높으므로 대책이 요구됨을 확인하였다.