참고문헌
- Lund, J., Sanner, B., Rybach, L., Curtis R., and Hellstrom, G., 2003, Ground-Source Heat Pumps-A World Overview, Renewable Energy World, pp. 218-227.
- DOE, 2001, Ground-source heat pumps applied to federal facilities-second edition, Federal Energy Management Program, DOE/EE-0245 (PNNL-13534), US Department of Energy.
- KEMCO, 2010, New and renewable energy statistics 2010, Report of Korea Energy Management Corporation, KEMCO, Yongin, Korea.
- Ministry of Knowledge Economy, 2009, Standards of support, installation, and management for new and renewable energy system, Ministry of Knowledge Enconmy Announcement 2009-332.
- Choi, J. M., Shim, C. H., Woo, J. T., and Kang, H. J., 2009, GSHP system and certification system, Magazine of the SAREK, Vol. 38, No. 1, pp. 35-41.
- Choi, J. M., Park, Y. J., and Kang, S. H., 2008, Heating performance verification of a ground source heat pump system with U-tube and double tube type GLHEs, Renewable Energy, Vol. 54, pp. 32-39.
- Chirstopher, J. W., Hao, L., and Saffa, B. R. 2012, Comparatative performance of 'U-tube' and 'coaxial' loop designs for use with a ground source heat pump, Applied Thermal Engineering, Vol. 37, pp. 190-195. https://doi.org/10.1016/j.applthermaleng.2011.11.015
- Qian, H., 2014, Modeling the interactions between the performance of ground sourece heat pumps and soil temperature variations, Energy for Sustainable Development, Vol. 23, pp. 115-121. https://doi.org/10.1016/j.esd.2014.08.004
- Michopoulos, A., Zachariadis, T., and Kyriakis, N., 2013, Operation characteristics and experience of a ground source heat pump system with a vertical ground heat exchanger, Energy, Vol. 51, pp. 349-357. https://doi.org/10.1016/j.energy.2012.11.042
- Sepehr, S. and Behzad, N. 2009, Thermal-economic modeling and optimization of vertical ground-coupled heat pump, Energy Conversion and Management, Vol. 50, pp. 1136-1147. https://doi.org/10.1016/j.enconman.2008.11.014
- Kadir, B., 2010, Evaluation of the performance of a ground-source heat-pump system with series GHE in the cold climate region, Energy, Vol. 35, pp. 349-360.
- Rasim, K., Sengul, G., and Halil, L., 2011, Experimental investigation of the cooling performance of a ground source heat pump system in Denizli, Turkey, International Journal of refrigeration, Vol. 34, pp. 454-465. https://doi.org/10.1016/j.ijrefrig.2010.10.009
- Yu, X., Zhai, X, Q., and Wang, R. Z., 2011, Design and performance of a constant temperautuer and humidity air-conditioning system driven by ground source heat pumps in winter, Energy Conversion and Management, Vol. 51, pp. 2162-2168.
- Xiaoyu, L., Long, N., and Siukit, L., 2011, Performance analysis of a multi-functional heat pump system in cooling mode, Applied Thermal Engineering, Vol. 59, pp. 253-266.
- Ministry of Knowledge Economy, 2008, Plastic water pipes-PE-Part 2: Pipe, KS M 3408-2(Korea).
- International Groud Source Heat Pump Association, 2009, Ground source heat pump residential and light commercial design and installation guide, International Groud Source Heat Pump Association, U.S.A.
- Ji, W. T., Zhang, D. C., He, Y. L., and Tao, W. Q., 2012, Prediction of fully developed turbulent heat transfer of internal helically ribbed tubes-An extension of Gnielinski equation, International Journal of Heat and Mass Transfer, Vol. 55, pp. 1375-1384. https://doi.org/10.1016/j.ijheatmasstransfer.2011.08.028
- Cho, H. and Choi, J. M., 2014, The quantitative evaluation of design parameter's effects on a ground source heat pump system, Renewable Energy, Vol. 65, pp. 2-6. https://doi.org/10.1016/j.renene.2013.06.034
피인용 문헌
- Analysis on Thermal Performance of Ground Heat Exchanger According to Design Type Based on Thermal Response Test vol.12, pp.4, 2019, https://doi.org/10.3390/en12040651