참고문헌
- 대한건축학회(2004) 콘크리트 충전강관구조 요설, 기문당. AIK (2004) Concrete Filled Tube (CFT) Structures, The Architectural Institute of Korea, Kimoondang (in Korean).
- 한국강구조학회(1999) 충전강관기둥의 내화성능평가 및 설계법에 관한 연구 보고서. KSSC (1999) Research Report on Fire Performance Evaluation and Design of Filled Steel tube Columns, Korea Society of Steel Construction (in Korean).
- Kodur, V.K.R. and Mackinnon, D.H. (2000) Design of Concrete Filled Hollow Structural Steel Column for Fire Endurance, Engineering Journal, AISC, Vol.37, No.1, pp.13-24.
- Han, H.H., Xhao, X.L., Yang, Y.F., and Feng, J.B. (2003) Experimental Study and Calculation of Fire Resistance of Concrete Filled Hollow Steel Columns, Journal of Structural Engineering ASCE, Vol.129, No.3, pp.346-356. https://doi.org/10.1061/(ASCE)0733-9445(2003)129:3(346)
- Kodur, V.K.R. and Wang, T.C. (2004) Stress-Strain Curve for High Strength Concrete At Elevated Temperature, Journal of Materials in Civil Engineering, Vol.16, No.1, pp.84-94. https://doi.org/10.1061/(ASCE)0899-1561(2004)16:1(84)
- Zhou, X. (2007) Effects of Hollowness on Strength of Double Skinned Concrete Filled Steel Tubular Columns of Different Geometries under Axial Loading, Advances in Structural Engineering, 94 pp. 1746-1751.
- 구철회, 이철호, 안재권(2013) 화재 시 무피복 CFT 기둥의 축강도 평가를 위한 단면온도분포 예측기법의 개발, 한국강구조학회논문집, 한국강구조학회, 제25권, 제6호, pp.587-599. Koo, C.H., Lee, C.H., and Ahn, J.K. (2013) Prediction of Temperature Distribution to Evaluate Axial Strength of Unprotected Concrete-filled Steel Tubular Columns under Fire, Journal of Korean Society of Steel Construction, KSSC, Vol. 25, No. 6, pp.587-599 (in Korean).
- 김해수 이치형(2010) 내화피복종류에 따른 각형 CFT기둥의 온도분포에 관한 실험적 연구, 한국강구조학회논문집, 한국강구조학회, 제 22권, 제6호 pp.523-532. Kim, HS. and Lee, C.H. (2010), An Experimental Study on the Temperature Distribution of Square CFT Columns According to the Types of Fire Protection, Journal of Korean Society of Steel Construction, KSSC, Vol.22, No.6, pp.523-532 (in Korean).
- 김선희, 염경수, 최성모(2013) 내부 앵커형 콘크리트 충전 기둥의 내력 및 변형 능력에 관한 연구, 한국강구조학회논문집, 한국강구조학회, 제 25권, 제4호, pp.347-357. Kim, S.H., Yom, K.S., and Choi, S.M. (2013) A Study on the Load Carrying Capacity and Deformation capacity of the Internal Anchors Welded Cold Formed Concrete Filled Columns, Journal of Korean Society of Steel Construction, KSSC, Vol.25, No.4, pp.347-357 (in Korean).
- Kim, S.H., Yom, K.S., and Choi, S.M. (2014) Improving fire Performance with Steel Fibers for Internally Anchored Square Composite Columns, Journal of Constructional Steel Research, Vol.103, pp.264-274. https://doi.org/10.1016/j.jcsr.2014.09.003
- 김선희, 염경수, 김용환, 최성모(2014) 내화성능 개선을 위한 강섬유 보강 내부 앵커형 각형강관 합성기둥의 실험연구, 한국강구조학회논문집, 한국강구조학회, Vol.26, No.6, pp.499-509. Kim, S.H., Yom, K.S., Kim, Y.H., and Choi, S.M. (2014) Experimental Study of Improving fire Performance with Steel Fibers for Internally Anchored Square Composite Columns, Journal of Korean Society of Steel Construction, KSSC, Vol.26, No.4, Vol.26, No.6, pp.499-509 (in Korean).
- Kodur, V.K.R. and Lie, T.T. (1996a) Thermal and Mechanical Properties of Steel Fiber Reinforced Concrete at Elevated Temperatures, Canada Journal Civil Engineering, Vol.23, No.2, pp.511-517. https://doi.org/10.1139/l96-055
- Kodur, V.K.R. and Lie, T.T. (1997) Evaluation of fire Resistance of Rectangular Steel Columns Filled with Fiber-Reinforced Concrete, Canadian Journal of Civil Engineering, Vol.24, No.3, pp.339-349. https://doi.org/10.1139/l96-114
- Kodur, V.K.R., Lie, T.T. (1996b) Fire Resistance of Circular Steel Ccolumns Filled with Fiber Reinforced Concrete, Journal of Structural Engineering, Vol.122, No.7, pp.776-782. https://doi.org/10.1061/(ASCE)0733-9445(1996)122:7(776)
- 문도영(2013) 고온노출된 강섬유 보강 콘크리트 인장성능에 대한 실험적 연구, 한국방재학회논문집, 한국방재학회, 제13권, 제1호, pp.63-71. Moon, D.Y. (2013) Experimental Study on Tensile Strength of Steel Fiber-Reinforced Concrete Subjected to High Temperature, Journal of the Korean Society of Hazard Mitigation, Vol.13, No.1, pp.63-71 (in Korean).
- DIN (1988) Normen AusschuB: Beton und Stahlbetos, Bemussung und Ausfuhrung-DIN 1045, Germany, (in German).
- JSCE (1984) Method of tests for flexural strength and flexural toughness of steel-fiber-reinforced concrete, Concrete library of JSCE-SF4: V3, Japan Society of Civil Engineers, Tokyo, pp.58-61 (in Japanese).
- Lie, T.T. and Irwin, R.J. (1995) Fire Resistance of Rectangular Steel Columns Filled with Bar-Reinforced Concrete, Journal of structural Engineering May, pp. 797-805.
- Ding, J. and Wang, Y.C. (2008) Realistic Modelling of Thermal and Structural Behavior of Unprotected Concrete Filled Tubular Columns in Fire, Journal of Construction Steel Research, Vol.64, No. 10, pp.1086-1102. https://doi.org/10.1016/j.jcsr.2007.09.014
- Hong, S.D. and Amit, H.V. (2009) Analytical Modeling of the Standard Behavior of Loaded CFT Columns, Journal of Constructional Steel Research, Vol.65, No. 1, pp.54-69. https://doi.org/10.1016/j.jcsr.2008.04.008
- EN 1994-1-1 (1992) Design of Composite Structures, Part1.1 : General Rules for Building.
- EN 1991-1-2 (2002) Eurocode-1, Actions on structures - Part 1-2: General actions -Actions on structures exposed to fire.
피인용 문헌
- 연속체 모델과 지하구조물 고정단 모델의 비교를 통한 SSI 해석의 타당성 연구 vol.20, pp.5, 2016, https://doi.org/10.9711/ktaj.2018.20.5.757
- Experimental Study on the Fire Resistance of Steel-Reinforced Concrete Column in Fire According to Load Ratio vol.31, pp.6, 2016, https://doi.org/10.7781/kjoss.2019.31.6.459