DOI QR코드

DOI QR Code

Evaluation of Daylighting Performance in Office Building with Detailed Global Illuminance Data of Selected Korean Cities

정밀 전천공조도 데이터를 활용한 국내 주요도시 업무용 건물의 자연채광 활용성능 평가

  • Choi, Su-Hyun (Department of Architectural Engineering, Chungbuk University) ;
  • Shin, Sang-Yong (Department of Architectural Engineering, Chungbuk University) ;
  • Seo, Dong-Hyun (Department of Architectural Engineering, Chungbuk University)
  • 최수현 (충북대학교 건축공학과) ;
  • 신상용 (충북대학교 건축공학과 대학원) ;
  • 서동현 (충북대학교 건축공학과)
  • Received : 2016.09.04
  • Accepted : 2016.12.19
  • Published : 2016.12.30

Abstract

In this study, long-term global illuminance data for 19 selected cities are calculated from modeled solar radiation data, AEER's TMY2. Perez model in Daysim daylight simulation tool is used for the solar radiation to illuminance conversion. And then, daylight availability in an unit office space is evaluated for the 19 cities. For this evaluation, various daylight performance indices are reviewed since static daylight performance index such as daylight factor (DF) and annual average global illuminance value is not suitable for actual performance evaluation in terms of visual comfort and light energy saving of a space. This study evaluated daylighting performance of prototypical office space module by introducing DA (daylight autonomy) and UDI (Useful Daylight Illuminance) index for major cities of Korea. Result shows that there is upto 18% of illuminance level difference with annual average global illuminance data, but if we consider useful daylight in a space the illuminance level difference among the cities are only within 5%. This means that for sustainable building design especially in daylight design, amount of annual global illuminance is not important factor even in cloudy cities. Daylight design and daylight harvesting system would return similar energy saving impact regardless of building location.

Keywords

References

  1. Perez, R., Ineichen, P., Seals, R., Michalsky, J., and Stewart, R., Modeling Daylight Availability and Irradiance Components from Direct and Global Irradiance, Solar Energy, Vol. 44, No. 5, pp. 271-289, 1990. https://doi.org/10.1016/0038-092X(90)90055-H
  2. Seo, D. and Krarti, M., Hourly Solar Radiation Model Suitable for Worldwide Typical Weather File Generation, Journal of Solar Energy Engineering, Vol. 113, 041002, pp. 1-8, 2011.
  3. Seo, D. and Ihm, B., Comparative Solar Models Performance Analysis for Typical Meteorological Year Development of Korea, Journal of the Regional Association of Architectural Institute of Korea, Vol. 12, No. 1, pp. 147-154, 2010.
  4. MOLIT, Window Design Guide for Building Energy Efficiency, Ministry of Land, Infrastructure, and Transpotation, 2012.
  5. Choi, A. and Kim, G., A Study on Determination of Dimming Zones for Effective Application of Daylight Responsive Dimming Systems, Journal of Architectural Institute of Korea, Vol. 21, No. 6, pp. 157-164, 2005.
  6. Christoph, R., Tutorial on the Use of Daysim Simulation for Sustainable Design, NRCC, 2006.
  7. CIBSE BS 8206-2:2008, Lighting for Buildings. Code of Practice for Daylighting, 2008.
  8. Ko, D., Analysis of Useful Daylight Illuminance(UDI) by Dynamic Daylight Simulation Using Weather Data, Journal of Architectural Institute of Korea, Vol. 26, No. 6, pp. 321-331, 2010.
  9. Oh, M. and Yoon, J., A Study on the Evaluation of Daylighting Performance based on Weather Data Using The BIM Tools in Initial Design Step, Journal of Architectural Institute of Korea, Vol. 27, No. 6, pp. 267-274, 2011.
  10. Kim, H. and Kim, K., A Study on Daylighting Performance Evaluation for the Green Building Certification and Daylight Prediction According to Design Elements, Journal of Architectural Institute of Korea, Vol. 29, No. 7, pp. 239-246, 2013.
  11. Christoph, R., Experimental Validation Of 3D Max Design 2009 and Daysim 3.0, Eleventh International IBPSA Conference Glasgow, Scotland, 2009.
  12. Ihm, P., Nemri, A., and Krarti, M., Estimation of Lighting Energy Savings from Daylighting. Build Environ, Vol. 44, pp. 509-514, 2009. https://doi.org/10.1016/j.buildenv.2008.04.016
  13. Li, D. H. W., Cheung, A. C. K., Chow, S. K. H., and Lee, E. W. M., Study of Daylight Data and Lighting Energy Savings for Atrium Corridors with Lighting Dimming Controls, Energy Build, Vol. 72, pp. 457-464, 2014. https://doi.org/10.1016/j.enbuild.2013.12.027
  14. Yun, G. Y., Kim, H., and Kim, J. T., Effects of Occupancy and Lighting Use Patterns on Lighting Energy Consumption, Energy Build, Vol. 46, p. 152, 2012. https://doi.org/10.1016/j.enbuild.2011.10.034
  15. Chen, Y., Liu, J., Pei, J., Cao, X., Chen, Q., and Jiang, Y., Experimental and Simulation Study on the Performance of Daylighting in an Industrial Building and Its Energy Saving Potential, Energy Build, Vol. 73, pp. 184-191, 2014. https://doi.org/10.1016/j.enbuild.2014.01.030
  16. Krarti, M., Erickson, P. M., and Hillman, T. C., A Simplified Method to Estimate Energy Savings of Artificial Lighting Use from Daylighting, Build Environ, Vol. 40, pp. 747-754, 2005. https://doi.org/10.1016/j.buildenv.2004.08.007
  17. Roisin, B., Bodart, M., and Deneyer, A., D'Herdt P. Lighting Energy Savings in Offices using Different Control Systems and Their Real Consumption, Energy Build, Vol. 40, pp. 514-523, 2008. https://doi.org/10.1016/j.enbuild.2007.04.006
  18. Muneer, T., Gueymard, C., and Kambezidis, H., Solar Radiation and Daylight Models, (2nd Edition), Butterworth-Heinemann, Oxford, 2004.
  19. Cucumo, M., De Rosa, A., Ferraro, V., Kaliakatsos, D., and Marinelli, V., Correlations of Global and Diffuse Solar Luminous Efficacy for All Sky Conditions and Comparisons with Experimental Data of Five Localities, Renewable Energy, Vol. 33, No. 9, pp. 2036-2047, 2008. https://doi.org/10.1016/j.renene.2007.11.015

Cited by

  1. Study on the Prediction and Improvement of Indoor Natural Light and Outdoor Comfort in Apartment Complexes Using Daylight Factor and Physiologically Equivalent Temperature Indices vol.11, pp.7, 2018, https://doi.org/10.3390/en11071872