References
- Raigrodski AJ. Contemporary materials and technologies for all-ceramic fixed partial dentures: a review of the literature. J Prosthet Dent 2004;92:557-62. https://doi.org/10.1016/j.prosdent.2004.09.015
- Tinschert J, Natt G, Mohrbotter N, Spiekermann H, Schulze KA. Lifetime of alumina-and zirconia ceramics used for crown and bridge restorations. J Biomed Mater Res B Appl Biomater, 2007;80:317-21.
- Manicone PF, Rossi Iommetti P, Raffaelli L. An overview of zirconia ceramics: basic properties and clinical applications. J Dent 2007; 5:819-26
- Sundh A, Molin M, Sjogren G. Fracture resistance of yttrium oxide partially-stabilized zirconia allceramic bridges after veneering and mechanical fatigue testing. Dent Mater 2005;21:476-82. https://doi.org/10.1016/j.dental.2004.07.013
- Coelho PG, Silva NR, Bonfante EA, Guess PC, Rekow ED, Thompson VP (2009) Fatigue testing of two porcelain-zirconia all-ceramic crown systems. Dent Mater 2009;25:1122-7. https://doi.org/10.1016/j.dental.2009.03.009
- Heintze SD, Rousson V. Survival of zirconia-and metal-supported fixed dental prostheses: a systematic review. Int J Prosthodont 2010;23:493-502.
- Swain MV. Unstable cracking (chipping) of veneering porcelain on all-ceramic dental crowns and fixed partial dentures. Acta Biomater 2009; 5:1668-77. https://doi.org/10.1016/j.actbio.2008.12.016
- Taskonak B, Borges GA, Mecholsky JJ, Anusavice KJ, Moore BK, Yan J. The effects of viscoelastic parameters on residual stress development in a zirconia/glass bilayer dental ceramic. Dent Mater 2008;24:1149-55. https://doi.org/10.1016/j.dental.2008.01.004
- McLaren EA, White SN. Glass-infiltrated zirconia/alumina based ceramic for crowns and fixed partial dentures. Pract Periodontics Aesthet Dent 1999;11:985-94.
- Goodacre CJ, Campagni WV, Aquilino SA. Tooth preparations for complete crowns: an art form based on scientific principles. J Prosthet Dent 2001;85:363-76 https://doi.org/10.1067/mpr.2001.114685
- Fenske C, Jarren MP, Sadat-Khhonsari MR. Fracture strength of full ceramic crowns in dependence of the preparation width. Dtsch Zahnarztl Z 1999;54:732-34.
- Meier M, Fischer H, Richter EJ, Maier HR. Influence of different preparation forms on the fracture resistance of full-ceramic molar crowns. Dtsch Zahnarztl Z 1995;50:295-9.
- Beuer F, Edelhoff D, Gernet W, Naumann M. Effect of preparation angles on the precision of zirconia crown copings fabricated by CAD/CAM system. Dent Mater J 2008;27:814-20. https://doi.org/10.4012/dmj.27.814
- Vult von Steyern P. All-ceramic fixed partial dentures. Studies on aluminum oxide-and zirconium dioxide-based ceramic systems. Swed Dent J 2005;Suppl 173:61-9.
- Kern M. Clinical long-term survival of two-retainer and single-retainer all-ceramic resin-bonded fixed partial dentures. Quintessence Int 2005;36:141-7.
- Ghazal M, Kern M. The influence of antagonistic surface roughness on the wear of human enamel and nanofilled composite resin artificial teeth. J Prosthet Dent 2009;101:342-9. https://doi.org/10.1016/S0022-3913(09)60068-8
-
Kobayashi K, Kuwajima H, Masaki T. Phase change and mechanical properties of
$ZrO_2$ -$Y_2O_3$ solid electrolyte after aging. Solid State Ionics 1981;3:489-93. - Chevalier J, Cales B, Drouin JM. Low temperature aging of Y-TZP ceramics. J Am Ceram 1999;82:2150-4.
- Lughi V, Sergo V. Low temperature degradation-aging-of zirconia: a critical review of the relevant aspects in dentistry. Dent Mater 2010;26:807-20. https://doi.org/10.1016/j.dental.2010.04.006
- Ardlin I. Transformation-toughened zirconia for dental inlays, crowns and bridges: chemical stability and effect of lowtemperature aging on flexural strength and surface structure. Dent Mater 2002;18:590-5. https://doi.org/10.1016/S0109-5641(01)00095-1
- Papanagiotou HP, Morgano SM, Giordano RA, Pober R. In vitro evaluation of low-temperature aging effects and finishing procedures on the flexural strength and structural stability of Y-TZP dental ceramics. J Prosthet Dent 2006;96:154-64. https://doi.org/10.1016/j.prosdent.2006.08.004
- Kim JW, Covel NS, Guess PC, Rekow ED, Zhang Y. Concerns of hydrothermal degradation in CAD/CAM zirconia. J Dent Res 2010;89:91-5. https://doi.org/10.1177/0022034509354193
-
Deville S, Chevalier J, Dauvergne C, Fantozzi G, Bartolome JF, Moya JS, Torrecillas R. Microstructural investigation of the aging behavior of (3Y-TZP)-
$Al_2O_3$ composites. J Am Ceram Soc 2005;88:1273-80. https://doi.org/10.1111/j.1551-2916.2005.00221.x - Snyder MD, Hogg KD. Load-to-fracture value of different all-ceramic crown systems. J Contemp Dent Pract 2005;6:54-63.
- Lang NP. Periodontal considerations in prosthetic dentistry. Periodontol 2000; 9:118-31.
- Preis V, Schmalzbauer M, Bougeard D, Schneider-Feyrer S, Rosentritt M. Surface properties of monolithic zirconia after dental adjustment treatments and in vitro wear simulation. J Dent 2015;43:133-9. https://doi.org/10.1016/j.jdent.2014.08.011
- Akar GC, Pekkan G, Cal E, Eskitascioglu G, Ozcan M. Effects of surface-finishing protocols on the roughness, color change, and translucency of different ceramic systems. J Prosthet Dent 2014;112:314-21. https://doi.org/10.1016/j.prosdent.2013.09.033
- Kou W, Molin M, Sjogren G. Surface roughness of five different dental ceramic core materials after grinding and polishing. J Oral Rehabil 2006;33:117-24. https://doi.org/10.1111/j.1365-2842.2006.01546.x
- Monasky GE, Taylor DF. Studies on the wear of porcelain, enamel, and gold. J Prosthet Dent 1971;25:299-306. https://doi.org/10.1016/0022-3913(71)90191-0
- Oh WS, Delong R, Anusavice KJ. Factors affecting enamel and ceramic wear: a literature review. J Prosthet Dent 2002; 87:451-9. https://doi.org/10.1067/mpr.2002.123851
- Kosmac T, Oblak C, Jevnikar P, Funduk N, Marion L. The effect of surface grinding and sandblasting on flexural strength and reliability of Y-TZP zirconia ceramic. Dent Mater 1999;15:426-33. https://doi.org/10.1016/S0109-5641(99)00070-6
- Rosentritt M, Behr M, van der Zel JM, Feilzer AJ. Approach for valuating the influence of laboratory simulation. Dent Mater 2009;25:348-52. https://doi.org/10.1016/j.dental.2008.08.009
- DeLong R, Douglas WH. An artificial oral environment for testing dental materials. IEEE Trans Biomater Eng 1991;38:339-45. https://doi.org/10.1109/10.133228
- Krejci I, Reich T, Lutz F, Albertson M. In-vitro test method for evaluation of dental restorations. Schweiz Monatsschr Zahnmed 1990;100:8-12.
- Teoh SH, Ong LF, Yap AU, Hastings GW. Bruxing-type dental wear simulator for ranking of dental restorative materials. J Biomed Mater Res 1998;43:175-83. https://doi.org/10.1002/(SICI)1097-4636(199822)43:2<175::AID-JBM12>3.0.CO;2-H
- Gale MS, Darvell BW. Thermal cycling procedures for laboratory testing of dental restorations. J Dent 1999;27:89-99. https://doi.org/10.1016/S0300-5712(98)00037-2
- Senyilmaz DP, Canay S, Heydecke G, Strub JR. Influence of thermomechanical fatigue loading on the fracture resistance of all-ceramic posterior crowns. Eur J Prosthodont Restor Dent, 2010;18:50-4.
- Lee JK, Kim H. Surface crack initiation in 2Y-TZP ceramics by low temperature aging. Ceram Int 1994;20:413-8. https://doi.org/10.1016/0272-8842(94)90028-0
- Lance MJ, Vogel EM, Reith LA, Cannon RW. Lowtemperature aging of zirconia ferrules for optical connectors. J Am Ceram Soc 2001;84:2731-3. https://doi.org/10.1111/j.1151-2916.2001.tb01085.x
- Zhenglan L, Danyu J, Lei H, Guoqiang Z, Qiang L, Cheng Z. Low temperature degradation of yttria stabilized zirconia. Key Engineering Mater 2007;336-338:1188-9. https://doi.org/10.4028/www.scientific.net/KEM.336-338.1188
Cited by
- study vol.9, pp.3, 2017, https://doi.org/10.4047/jap.2017.9.3.208
- Comparative fracture behavior of monolithic and veneered zirconia posterior fixed dental prostheses vol.36, pp.6, 2017, https://doi.org/10.4012/dmj.2016-391
- Retrospective clinical evaluation of posterior monolithic zirconia restorations after 1 to 3.5 years of clinical service vol.60, pp.1, 2016, https://doi.org/10.2334/josnusd.17-0176
- Monolithic zirconia crowns - wall thickness, surface treatment and load at fracture vol.6, pp.1, 2016, https://doi.org/10.1080/26415275.2019.1642112
- Monolithic Zirconia: An Update to Current Knowledge. Optical Properties, Wear, and Clinical Performance vol.7, pp.3, 2016, https://doi.org/10.3390/dj7030090
- Current status on lithium disilicate and zirconia: a narrative review vol.19, pp.1, 2016, https://doi.org/10.1186/s12903-019-0838-x
- Root canal reconstruction using biological dentin posts: A 3D finite element analysis vol.13, pp.4, 2016, https://doi.org/10.15171/joddd.2019.042
- Influence of preparation design on fracture resistance of different monolithic zirconia crowns: A comparative study vol.11, pp.6, 2016, https://doi.org/10.4047/jap.2019.11.6.324
- Assessment of Teeth Prepared by Senior Dental Students for CAD/CAM Restorations vol.84, pp.3, 2016, https://doi.org/10.21815/jde.019.178
- Cracked Tooth Syndrome Management Part 2: Integrating the Old with the New vol.47, pp.7, 2016, https://doi.org/10.12968/denu.2020.47.7.570
- Fracture resistance and marginal fit of the zirconia crowns with varied occlusal thickness vol.12, pp.5, 2016, https://doi.org/10.4047/jap.2020.12.5.283
- Strength and aging resistance of monolithic zirconia: an update to current knowledge vol.56, pp.1, 2016, https://doi.org/10.1016/j.jdsr.2019.09.002
- Effect of artificial aging on high translucent dental zirconia: simulation of early failure vol.128, pp.6, 2016, https://doi.org/10.1111/eos.12739
- In Vitro Fatigue and Fracture Load of Monolithic Ceramic Crowns Supported by Hybrid Abutment vol.15, pp.1, 2016, https://doi.org/10.2174/1874210602115010664
- Assessment of Tooth Preparations Submitted to Dental Laboratories for Fabrication of Monolithic Zirconia Crowns vol.9, pp.10, 2016, https://doi.org/10.3390/dj9100112
- Evaluation of Marginal/Internal Fit and Fracture Load of Monolithic Zirconia and Zirconia Lithium Silicate (ZLS) CAD/CAM Crown Systems vol.14, pp.21, 2016, https://doi.org/10.3390/ma14216346