References
- Schweitzer DM, Goldstein GR, Ricci JL, Silva NR, Hittelman EL. Comparison of bond strength of a pressed ceramic fused to metal versus feldspathic porcelain fused to metal. J Prosthodont 2005;14:239-47. https://doi.org/10.1111/j.1532-849X.2005.00052.x
- Zarone F, Russo S, Sorrentino R. From porcelain-fused-tometal to zirconia: clinical and experimental considerations. Dent Mater 2011;27:83-96. https://doi.org/10.1016/j.dental.2010.10.024
- Kern M, Sasse M, Wolfart S. Ten-year outcome of three-unit fixed dental prostheses made from monolithic lithium disilicate ceramic. J Am Dent Assoc 2012;143:234-40. https://doi.org/10.14219/jada.archive.2012.0147
- Raigrodski AJ, Hillstead MB, Meng GK, Chung KH. Survival and complications of zirconia-based fixed dental prostheses: a systematic review. J Prosthet Dent 2012;107:170-7. https://doi.org/10.1016/S0022-3913(12)60051-1
- Drummond JL, Randolph RG, Jekkals VJ, Lenke JW. Shear testing of the porcelain-metal bond. J Dent Res 1984;63: 1400-1. https://doi.org/10.1177/00220345840630121201
- Rake PC, Goodacre CJ, Moore BK, Munoz CA. Effect of two opaquing techniques and two metal surface conditions on metal-ceramic bond strength. J Prosthet Dent 1995;74:8-17. https://doi.org/10.1016/S0022-3913(05)80222-7
- Venkatachalam B, Goldstein GR, Pines MS, Hittelman EL. Ceramic pressed to metal versus feldspathic porcelain fused to metal: a comparative study of bond strength. Int J Prosthodont 2009;22:94-100.
- Paulino SM, Leal MB, Pagnano VO, Bezzon OL. The castability of pure titanium compared with Ni-Cr and Ni-Cr-Be alloys. J Prosthet Dent 2007;98:445-54. https://doi.org/10.1016/S0022-3913(07)60143-7
- Nogueira F, Fais LM, Fonseca RG, Adabo GL. The influence of short-heating-cycle investments on the quality of commercially pure titanium castings. J Prosthet Dent 2010;104: 265-72. https://doi.org/10.1016/S0022-3913(10)60136-9
- Homann F, Waddell JN, Swain MV. Influence of water, loading rate and bonder on the adhesion of porcelain to titanium. J Dent 2006;34:485-90. https://doi.org/10.1016/j.jdent.2005.11.004
- Tholey MJ, Waddell JN, Swain MV. Influence of the bonder on the adhesion of porcelain to machined titanium as determined by the strain energy release rate. Dent Mater 2007;23: 822-8. https://doi.org/10.1016/j.dental.2006.06.022
- Vasquez VZ, Ozcan M, Kimpara ET. Evaluation of interface characterization and adhesion of glass ceramics to commercially pure titanium and gold alloy after thermal-and mechanical-loading. Dent Mater 2009;25:221-31. https://doi.org/10.1016/j.dental.2008.07.002
- Eliasson A, Arnelund CF, Johansson A. A clinical evaluation of cobalt-chromium metal-ceramic fixed partial dentures and crowns: A three-to seven-year retrospective study. J Prosthet Dent 2007;98:6-16. https://doi.org/10.1016/S0022-3913(07)60032-8
- Sailer I, Pjetursson BE, Zwahlen M, Hammerle CH. A systematic review of the survival and complication rates of allceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part II: Fixed dental prostheses. Clin Oral Implants Res 2007;18:86-96.
- Lombardo GH, Nishioka RS, Souza RO, Michida SM, Kojima AN, Mesquita AM, Buso L. Influence of surface treatment on the shear bond strength of ceramics fused to cobalt-chromium. J Prosthodont 2010;19:103-11. https://doi.org/10.1111/j.1532-849X.2009.00546.x
- Grimaudo NJ. Biocompatibility of nickel and cobalt dental alloys. Gen Dent 2001;49:498-503.
- Wassell RW, Walls AW, Steele JG. Crowns and extra-coronal restorations: materials selection. Br Dent J 2002;192:199-202, 205-11. https://doi.org/10.1038/sj.bdj.4801334
- Yfantis C, Yfantis D, Anastassopoulou J, Theophanides T. Analytical and electrochemical evaluation of the in vitro corrosion behavior of nickel-chrome and cobalt-chrome casting alloys for metal-ceramic restorations. Eur J Prosthodont Restor Dent 2007;15:33-40.
- Mackert JR Jr, Ringle RD, Parry EE, Evans AL, Fairhurst CW. The relationship between oxide adherence and porcelain-metal bonding. J Dent Res 1988;67:474-8. https://doi.org/10.1177/00220345880670020801
- Yilmaz H, Dincer C. Comparison of the bond compatibility of titanium and an NiCr alloy to dental porcelain. J Dent 1999;27:215-22. https://doi.org/10.1016/S0300-5712(98)00045-1
- Hegedus C, Daroczi L, Kokenyesi V, Beke DL. Comparative microstructural study of the diffusion zone between NiCr alloy and different dental ceramics. J Dent Res 2002;81:334-7. https://doi.org/10.1177/154405910208100509
- Bowers JE, Vermilyea SG, Griswold WH. Effect of metal conditioners on porcelain-alloy bond strength. J Prosthet Dent 1985;54:201-3. https://doi.org/10.1016/0022-3913(85)90288-4
- Roberts HW1, Berzins DW, Moore BK, Charlton DG. Metalceramic alloys in dentistry: a review. J Prosthodont 2009;18: 188-94. https://doi.org/10.1111/j.1532-849X.2008.00377.x
- Sarantopoulos DM, Beck KA, Holsen R, Berzins DW. Corrosion of CoCr and NiCr dental alloys alloyed with palladium. J Prosthet Dent 2011;105:35-43. https://doi.org/10.1016/S0022-3913(10)60188-6
- Wu Y, Moser JB, Jameson LM, Malone WF. The effect of oxidation heat treatment of porcelain bond strength in selected base metal alloys. J Prosthet Dent 1991;66:439-44. https://doi.org/10.1016/0022-3913(91)90502-N
- de Vasconcellos LG, Buso L, Lombardo GH, Souza RO, Nogueira L Jr, Bottino MA, Ozcan M. Opaque layer firing temperature and aging effect on the flexural strength of ceramic fused to cobalt-chromium alloy. J Prosthodont 2010; 19:471-7. https://doi.org/10.1111/j.1532-849X.2010.00600.x
- Oliveira de Vasconcellos LG, Silva LH, Reis de Vasconcellos LM, Balducci I, Takahashi FE, Bottino MA. Effect of airborne-particle abrasion and mechanico-thermal cycling on the flexural strength of glass ceramic fused to gold or cobaltchromium alloy. J Prosthodont 2011;20:553-60. https://doi.org/10.1111/j.1532-849X.2011.00761.x
- Gavelis JR, Lim SB, Guckes AD, Morency JD, Sozio RB. A comparison of the bond strength of two ceramometal systems. J Prosthet Dent 1982;48:424-8. https://doi.org/10.1016/0022-3913(82)90079-8
- Bienias J, Surowska B, Stoch A, Matraszek H, Walczak M. The influence of SiO2 and SiO2-TiO2 intermediate coatings on bond strength of titanium and Ti6Al4V alloy to dental porcelain. Dent Mater 2009;25:1128-35. https://doi.org/10.1016/j.dental.2009.01.107
- Saito A, Komine F, Blatz MB, Matsumura H. A comparison of bond strength of layered veneering porcelains to zirconia and metal. J Prosthet Dent 2010;104:247-57. https://doi.org/10.1016/S0022-3913(10)60133-3
- Wu Y, Moser JB, Jameson LM, Malone WF. The effect of oxidation heat treatment of porcelain bond strength in selected base metal alloys. J Prosthet Dent 1991;66:439-44. https://doi.org/10.1016/0022-3913(91)90502-N
- Kononen M, Kivilahti J. Fusing of dental ceramics to titanium. J Dent Res 2001;80:848-54. https://doi.org/10.1177/00220345010800030101
- Al Hussaini I, Al Wazzan KA. Effect of surface treatment on bond strength of low-fusing porcelain to commercially pure titanium. J Prosthet Dent 2005;94:350-6. https://doi.org/10.1016/j.prosdent.2005.07.007
- Kulunk T, Kurt M, Ural C, Kulunk S, Baba S. Effect of different air-abrasion particles on metal-ceramic bond strength. J Dent Sci 2011;6:140-6. https://doi.org/10.1016/j.jds.2011.05.003
- Sipahi C, Ozcan M. Interfacial shear bond strength between different base metal alloys and five low fusing feldspathic ceramic systems. Dent Mater J 2012;31:333-7. https://doi.org/10.4012/dmj.2011-143
- Graham JD, Johnson A, Wildgoose DG, Shareef MY, Cannavina G. The effect of surface treatments on the bond strength of a nonprecious alloy-ceramic interface. Int J Prosthodont 1999;12:330-4.
- Shimoe S, Tanoue N, Yanagida H, Atsuta M, Koizumi H, Matsumura H. Comparative strength of metal-ceramic and metal-composite bonds after extended thermocycling. J Oral Rehabil 2004;31:689-94. https://doi.org/10.1111/j.1365-2842.2004.01391.x
Cited by
- Comparison of the Structure and Properties of the Solid Co-Cr-W-Mo-Si Alloys Used for Dental Restorations CNC Machined or Selective Laser-Sintered vol.9, pp.4, 2016, https://doi.org/10.1520/mpc20200023
- Effects of Bonding Agents on Metal-Ceramic Bond Strength of Co-Cr Alloys Fabricated by Selective Laser Melting vol.13, pp.19, 2016, https://doi.org/10.3390/ma13194322
- Simplified Acid Treatment Technique in Cobalt-Chromium Alloys: Effect on Metal-Ceramic Bond Strength vol.24, pp.6, 2016, https://doi.org/10.1590/1980-5373-mr-2021-0247
- Establishment of a New Biomechanical Measurement Method for Surface Deformation of Bone by Force Application via Dental Implants-A Pilot Study vol.11, pp.16, 2021, https://doi.org/10.3390/app11167568