DOI QR코드

DOI QR Code

Development of Real Time Smart Structure Monitoring System for Bridge Safety Maintenance using Sensor Network

센서 네트워크 기반 실시간 교량 안전관리를 위한 지능형 구조 건전성 모니터링시스템 개발

  • 조병완 (한양대학교 건설환경공학과) ;
  • 김헌 (한양대학교 건설환경공학과) ;
  • 이윤성 (한양대학교 건설환경공학과) ;
  • 김도근 (한양대학교 건설환경공학과)
  • Received : 2015.08.17
  • Accepted : 2015.09.09
  • Published : 2016.02.28

Abstract

As structures' long term performances and users' safety have been highlighted, a new maintenance technique using IT has drawn attention around the globe. Therefore, throughout the paper, by analyzing bridge's static and dynamic data using wireless measuring sensor, a "real time smart bridge monitoring system" has developed. Smart bridge monitoring system is consists of three main parts a sensor that can measure major members' movement, a wireless system that informs the data from the sensor, and the database system that analysis the data. In order to test the performance of the system, five different were placed on the Olympic Bridge, Seoul. The power system of the sensors was replaced by self-sustain solar energy system. In order to validate data from the real time smart bridge monitoring system, the data was collected for a week from both wireless system and the wired system and the two data were compared to see the relevance.

최근 교량의 장수명화와 이용자의 안전을 보장하기 위한 첨단IT기술을 이용한 유지관리 기법이 세계적으로 각광을 받고 있다. 이에 본 논문에서는 무선계측센서를 이용하여 교량의 정적 동적 데이터를 취득 및 분석하여 교량의 거동상태를 실시간으로 모니터링 할 수 있는 지능형 교량 구조 건전성 모니터링시스템을 개발하였다. 본 논문에서 개발한 모니터링 시스템은 교량의 주요 부재의 거동을 계측하기 위한 센서 및 계측데이터 전송을 위한 무선송수신시스템, 전체 시스템 관리를 위한 운영프로그램 및 데이터베이스로 구성되어 있다. 개발한 무선계측센서 기반의 모니터링 시스템의 성능검증을 위해 올림픽대교에 5종의 무선계측센서를 설치하였으며, 센서의 전원은 태양광 발전장치를 설치하여 자가 전원공급이 가능하도록 하였다. 성능검증을 위한 데이터는 시스템 구축완료 후 일주일간의 데이터를 활용하여, 유선시스템으로부터 취득된 데이터와 비교 분석하였으며, 이를 통행 지능형 구조 건전성 모니터링 시스템의 성능 및 실 교량 적용성을 검증하였다.

Keywords

References

  1. S. Y. Kim, Y. S. Shin, and G. H. Kim, "Case Study on the Maintenance of a Construction Monitoring using USN-bsed Data Acquisition," The Scientific World Journal, Vol.2014, pp.1-11, 2014.
  2. B. W. Jo, Y. S. Lee, H. Kim, and D. W. Lee, "A Study on Development of the Intelligent Bridge Maintenance System using RFID," Journal of the Korean Society of Civil Engineers, Vol.33, No.5, pp.2107-2124, September, 2013. https://doi.org/10.12652/Ksce.2013.33.5.2107
  3. H. Sohn, H. J. Jung, J. S. Kong, J. J. Lee, and S. H. Sim, "ICT Based Bridge Health Diagnosis and Integrated Maintenance Techniques," Magazine of the Korea institute for structural maintenance and inspection, Vol.18, No.1, pp.1-4, 2014.
  4. S. H. Sim, "Structural Health Monitoring of Bridges Using Wireless Smart Sensor Networks," Magazine of the Korea Concrete Institute, Vol.24, No.3, pp.34-36, 2012. https://doi.org/10.22636/MKCI.2012.24.3.34
  5. J. J. Lee, Y. S. Park, C. B. Yun, K. Y. Koo, and J. H. Yi, "An Overriew of Information Processing Techniques for Structural Health Monitoring of Bridges," Journal of the Computational Structural Engineering Institute of Korea, Vol.21, No.6, pp.615-632, 2008.
  6. B. G. Sim, S. B. Lee, and M. S. Chae, "Development of a Wireless Vibration Monitoring System for Structural Health Evaluation," Vol.20, No.2, pp.166-171, 2010. https://doi.org/10.5050/KSNVE.2010.20.2.166
  7. E. G. Straser and A. S. Kiremidjian, "A Modular Visual Approach to Damage Monitoring for Civil Structures," Proceedings of SPIE, Smart Structures and Materials, pp.112-122, 1996.
  8. Ducduy Ho, P. Y. Lee, S. Y. Lee, and J. T. Kim, "Vibration-based Structural Health Monitoring of Full-Scale Cable-Stayed Bridges Using Wireless Smart Sensors," Journal of the Korean Society of Hazard Mitigation, Vol.12, No.1, pp.75-82, 2012. https://doi.org/10.9798/KOSHAM.2012.12.1.075
  9. D. S. Hong and J. T. Kim, "Monitoring of Full-Scale Concrete Girder Bridge Using Acceleration Response," Journal of the Korea Institute for Structural Maintenance and Inspection, Vol.14, No.1, pp.165-174, 2010.
  10. K. Maser, R. Egri, A. Lichtenstein, and S. Chase, "Development of a Wireless Global Bridge Evaluation and Monitoring System (WGBEMS)," Proceedings of the Specialty Conference on Infrastructure Condition Assessment, pp.91-100, 1997.
  11. J. P. Lynch, Field Validation of a Wireless Structural Monitoring System on the Alamosa Canyon Bridge, SPIE 10th, Sandiego, CA, USA, March 2003.
  12. I. H. Bae and G. H. Ha, "Structural Health Monitoring of Yeongjong Suspension Bridge Using GPS," National Asset Management of civil Infrastructure, Vol.1, pp.173-177, 2008.
  13. K. M. Kim, C. S. Kang, B. J. Oh, and Y. H. Lee, "A Wireless Sensor Network with Reservation-based MAC Protocol for Bridge Monitoring Systems," Journal of Korean Institute of Information Technology, Vol.7, No.6, pp.121-127, 2009.
  14. H. S. Kim, Y. H. Kim, J. C. Park, and S. B. Shin, "Data Analysis and Health Index for Health Monitoring of Seohae Bridge," Journal of the Korean Society of Civil Engineers, Vol.33, No.2, pp.387-395, Mar. 2013. https://doi.org/10.12652/Ksce.2013.33.2.387
  15. J. M. Ko and Y. Q. Ni, "Technology Developments in Structural Health Monitoring of Large-Scale Bridges," Journal of the Engineering Structures, Vol.27, No.12, pp.1715-1725, 2005. https://doi.org/10.1016/j.engstruct.2005.02.021
  16. H. J. Lee and Y. H. Choi, "Data Statical Analysis based Data Filtering Scheme for Monitoring System on Wireless Sensor Network," Journal of Korean Contents Association, Vol.10, No.3, pp.53-63, 2010. https://doi.org/10.5392/JKCA.2010.10.3.053
  17. J. S. Kim and J. S. Lee, "Implemen tation of a Remote Controlling System between Server/Client based Mobile," Journal of Korean Contents Association, Vol.10, No.6, pp.106-114, 2010.