DOI QR코드

DOI QR Code

Simplified Design Procedure for Reinforced Concrete Columns Based on Equivalent Column Concept

  • Afefy, Hamdy M. (Department of Structural Engineering, Faculty of Engineering, Tanta University) ;
  • El-Tony, El-Tony M. (Department of Structural Engineering, Faculty of Engineering, Alexandria University)
  • Received : 2015.12.11
  • Accepted : 2016.02.13
  • Published : 2016.09.30

Abstract

Axially loaded reinforced concrete columns are hardly exist in practice due to the development of some bending moments. These moments could be produced by gravity loads or the lateral loads. First, the current paper presents a detailed analysis on the overall structural behavior of 15 eccentrically loaded columns as well as one concentrically loaded control one. Columns bent in either single curvature or double curvature modes are tested experimentally up to failure under the effect of different end eccentricities combinations. Three end eccentricities ratio were studied, namely, 0.1b, 0.3b and 0.5b, where b is the column width. Second, an expression correlated the decay in the normalized axial capacity of the column and the acting end eccentricities was developed based on the experimental results and then verified against the available formula. Third, based on the equivalent column concept, the equivalent pin-ended columns were obtained for columns bent in either single or double curvature modes. And then, the effect of end eccentricity ratio was correlated to the equivalent column length. Finally, a simplified design procedure was proposed for eccentrically loaded braced column by transferring it to an equivalent axially loaded pin-ended slender column. The results of the proposed design procedure showed comparable results against the results of the ACI 318-14 code.

Keywords

References

  1. Afefy H. M. (2007) Experimental and numerical instability analysis of high strength reinforced concrete systems. Ph.D. thesis, Faculty of Engineering, Tanta University, Tanta, Egypt, 244 pp.
  2. Afefy, H. M. (2012). Ultimate flexural rigidity for stability analysis of RC beam column members. Structural and Building, 165, 299-308.
  3. Afefy, H. M., Taher, S. F., & El-Metwally, S. E. (2009). A new design procedure for braced reinforced high strength concrete columns under uniaxial and biaxial compression. Arabian Journal for Science and Engineering, KFUPM, KSA, 34, 349-377.
  4. American Concrete Institute. (2014). ACI, Building Code Requirements for Structural Concrete (ACI 318-14) and Commentary. Farmington Hills, MI: ACI.
  5. Barrera, A. C., Bonet, J. L., Romero, M. L., & Miguel, P. F. (2011). Experimental tests of slender reinforced concrete columns under combined axial load and lateral force. Engineering Structures, 33, 3676-3689. https://doi.org/10.1016/j.engstruct.2011.08.003
  6. CAN/CSA-A23.3-04 (R2010) (2010) Design of concrete structures. Canadian Standard Association, Toronto, Ontario, Canada, 258 p.
  7. Chen W. F., Lui E. M. (1987). Structural stability: Theory and implementation, New York, NY: Elsevier Science Publishing Co., Inc., 483 pp.
  8. Chuang H., Kong F. K. (1997) Large scale tests on slender reinforced concrete columns. Journal of the Institution of the Structural Engineers, Nanyang Technological University, Singapore, 75, 410-416.
  9. Cranston W. B. (1972) Analysis and design of reinforced concrete columns. Cement and Concrete Association, No. 20, 54 p.
  10. Egyptian Code for Design and Construction of Reinforced Concrete Structures, (ECP 203-2007) 2007.
  11. El-Metwally, S. E. (1994). Method of segment length for instability analysis of reinforced concrete beam-columns. ACI Structural Journal, 91, 666-677.
  12. Ivanov, A. (2004). Special features for the design of slender columns in monolithic multistory buildings with the consideration of longitudinal bending. Journal of Concrete and Reinforced Concrete, 5, 27-29.
  13. MacGregor, J. G., Breen, J. E., & Pfrang, E. O. (1970). Design of slender columns. ACI Structural Journal, 67, 6-28.
  14. MacGregor, J. K., & Wight, J. G. (2009). Reinforced concrete:Mechanics and design (5th ed.). Upper Saddle River, NJ:Prentice Hall.
  15. Mari, R., & Hellesland, J. (2005). Lower slenderness limits for rectangular concrete columns. Journal of Structural Engineering, ASCE, 131, 85-95. https://doi.org/10.1061/(ASCE)0733-9445(2005)131:1(85)
  16. McCormac, J. C. (1998). Design of reinforced concrete (4th ed.). Menlo Park, CA: Addison-Wesley Longman, Inc.
  17. Milner, D. M., Spacone, E., & Frangopol, D. M. (2001). New light on performance of short and slender reinforced concrete columns under random loads. Engineering Structures, 23, 147-157. https://doi.org/10.1016/S0141-0296(00)00036-5
  18. Mirza, S. A., & MacGregor, J. G. (1982). Probabilistic study of strength of reinforced concrete members. Canadian Journal of Civil Engineering, 9, 431-448. https://doi.org/10.1139/l82-053
  19. Nilson, A. H. (2004). Design of concrete structures (10th ed.). New York, NY: McGw-Hill book Company.
  20. Park, H., & Paulay, T. (1975). Reinforced concrete structures. New York, NY: Wiley.
  21. Yalcin, C., & Saatcioglu, M. (2000). Inelastic analysis of reinforced concrete columns. Computers & Structures, 77, 539-555. https://doi.org/10.1016/S0045-7949(99)00228-X

Cited by

  1. Experimental and Numerical Researches on the Seismic Behavior of Tubular Reinforced Concrete Columns of Air-Cooling Structures vol.11, pp.3, 2016, https://doi.org/10.1007/s40069-017-0207-6
  2. Proposed model for strength analysis of HSC eccentrically loaded slender columns vol.70, pp.7, 2018, https://doi.org/10.1680/jmacr.17.00137
  3. Optimum Locations of Outriggers in a Concrete Tall Building to Reduce Differential Axial Shortening vol.12, pp.1, 2016, https://doi.org/10.1186/s40069-018-0323-y
  4. Strength Analysis of a Two-Layer PETF-Concrete Column with Allowance for Contact Interaction between Layers vol.2021, pp.None, 2016, https://doi.org/10.1155/2021/4517657
  5. Alternative Design Procedure for RC-Braced Long Columns Based on New Moment Magnifiers Matrix vol.2021, pp.None, 2016, https://doi.org/10.1155/2021/9921682
  6. Strength of eccentrically loaded slender columns made with high-strength concrete vol.174, pp.10, 2021, https://doi.org/10.1680/jstbu.19.00064