DOI QR코드

DOI QR Code

A Study on the Fracture Strength of the Cement Gap

Cement Gap에 따른 Zirconia Crown의 파절강도 비교

  • Kim, Nam-Joong (Department of Dental Technology & Science, Shinhan University) ;
  • Lee, Chung-Jae (Department of Dental Technology & Science, Shinhan University) ;
  • Kwak, Woon-Seon (Department of Oral Health Graduate School of Public Health & Social Welfare Dankook University)
  • 김남중 (신한대학교 치기공학과) ;
  • 이청재 (신한대학교 치기공학과) ;
  • 곽운선 (단국대학교 보건복지대학원 구강보건학과)
  • Received : 2016.10.31
  • Accepted : 2016.12.23
  • Published : 2016.12.30

Abstract

Purpose: This research is conducted for better clinical test of Zirconia as we find out the fracture strength difference of Zirconia on cement gaps of full Crown that made use of Zirconia which is somewhat being used in recent dental technology. Methods: We produced each nine of Zirconia Crown of Zirconia fracture cement gaps A group(0.03 mm), B group(0.05 mm), C group(0.08 mm) on cement gaps by use of CAD/CAM, and compared the results. We could end up getting conclusions as following. Results: There was fracture strength difference per cement gaps but no impact(P<0.05). There was difference between $1.962{\pm}0.259$ from group A and $2.005{\pm}0.367$ from group B, but no impact(P<0.05). There was difference between $1.962{\pm}0.259$ from group A and $2.478{\pm}0.331$ from group C, but it's hard to be considered as an impact(P<0.05). Conclusion: Because of the hight pressure 0.08 mm is fractured and Margin has a lot of empty space due to gap for 0.08 mm. To identify the difference between 0.08 mm and 0.05 mm, 0.08 mm is selected as a gap. Therefore when it comes to using 0.05 mm authentically 0.05 mm is quite practical to use as a gap.

Keywords

References

  1. Choi MS, Kim YS, Suh KW, Ryu JJ. Effect of surface treatment on the shear bond strength of a Zirconia core to veneering ceramic. The Journal of Korean Academy of Prosthodontics, 47(2), 206-214, 2009. https://doi.org/10.4047/jkap.2009.47.2.206
  2. Huh JB, Kim U, Kim HY, Kim JE, Lee JY, Kim YS, Jeon YC, Shin SW. Marginal and internal fitness of three-unit Zirconia cores fabricated using several CAD/CAM systems. The Journal of Korean Academy of Prosthodontics, 49(3), 236-244, 2011. https://doi.org/10.4047/jkap.2011.49.3.236
  3. Huh JB, Park CG, Kim HY, Park CK, Shin SW. Evaluation using Replica Technique on the marginal and internal fitness of Zirconia cores by several CAD/CAM systems. The Journal of Korean Academy of Prosthodontics, 48(2), 135-142, 2010. https://doi.org/10.4047/jkap.2010.48.2.135
  4. Kim DK, Lim JH, Lim HS. On the marginal fidelity of All-ceramic core using CAD/CAM System. The Journal of Korean Academy of Prosthodontics, 41, 20-34, 2003.
  5. Kim JH, Kim KB. Influence of high temperature of the porcelain firing process on the marginal fit of zirconia core. J Dent Hyg Sci, 13(2), 135-141, 2013.
  6. Kwon YJ, Lee YS, Park WH. Comparative study in marginal adaptation of Zirconia cores fabricated with 3 different CAD/CAM Systems. The Journal of Korean Academy of Prosthodontics, 46(1), 12-21, 2008.
  7. Park JH, Hwang JW, Shin SW, The study of flexural strength of various Zirconia ceramics. The Journal of Korean Academy of Prosthodontics, 42(2), 142-153, 2004.
  8. Pyo SW, Park YB, Kim JH, Lee KW. Maxillary anterior all ceramic restoration using digital impression and CAD/CAM. The Journal of Korean Academy of Prosthodontics, 49(3), 263-269, 2011. https://doi.org/10.4047/jkap.2011.49.3.263
  9. Seo JY, Park IN, Lee KW. Fracture strength between different connector designs of Zirconia core for posterior fixed partial dentures manufactured with CAD/CAM system. The Journal of Korean Academy of Prosthodontics, 44(1), 29-39, 2006.
  10. Song TJ, Yeo IS, Yong JH. Marginal fit of three-unit Zirconia anterior fixed dental prostheses fabricated using CAD/CAM and MAD/MAM system. The Journal of Korean Academy of Prosthodontics, 49(2), 145-151, 2011. https://doi.org/10.4047/jkap.2011.49.2.145
  11. Song YK, Cho IH, Lee JH. The marginal fidelity of Procera AllCeram alumina copings and crowns of patients, The Journal of Korean Academy of Prosthodontics, 46(5), 470-478, 2008. https://doi.org/10.4047/jkap.2008.46.5.470