References
- Sampath M, Shukla A, Rathore AS. Modeling of filtration processes-Microfiltration and depth filtration for harvest of a therapeutic protein expressed in pichia pastoris at constant pressure. Bioengineering 2014;1:260-277. https://doi.org/10.3390/bioengineering1040260
- Matsushita T, Matsui Y, Shirasaki N, Kato Y. Effect of membrane pore size, coagulation time, and coagulant dose on virus removal by a coagulation-ceramic microfiltration hybrid system. Desalination 2005;178:21-26. https://doi.org/10.1016/j.desal.2004.11.026
- Hudson H, Wolfner JP. Design of mixing tank and flocculation basins. J. Am. Water Works Assoc. 1976;59:1257.
- Vrale L, Jarden RM. Rapid mixing in water treatment. J. Am. Water Works Assoc. 1971;63:52-58. https://doi.org/10.1002/j.1551-8833.1971.tb04027.x
- Kawamura S. Consideration in improving flocculation. J. Am. Water Works Assoc. 1976;68:328-336. https://doi.org/10.1002/j.1551-8833.1976.tb02421.x
- Amirtharajah A, Mills KM. Rapid mix design for mechanisms of alum coagulation. J. Am. Water Works Assoc. 1982;74: 210-216. https://doi.org/10.1002/j.1551-8833.1982.tb04890.x
- Camp TR. Floc volume concentration. J. Am. Water Works Assoc. 1968;60:656-673. https://doi.org/10.1002/j.1551-8833.1968.tb03592.x
- Letterman RD, Quon JK, Gemmel RC. Influence of rapid mix parameters on flocculation. J. Am. Water Works Assoc. 1973;65:716-725. https://doi.org/10.1002/j.1551-8833.1973.tb01933.x
- Lai RJ, Hudson HE, Singley JE. Velocity gradient calibration of jar-test equipment. J. Am. Water Works Assoc. 1975;67: 553-557. https://doi.org/10.1002/j.1551-8833.1975.tb02294.x
- Mhaisalkar VA, Paramasivam R, Bhloe AG. Optimizing physical parameters of rapid mix design for coagulation-flocculation of turbid waters. Water Res. 1991;25:43-52. https://doi.org/10.1016/0043-1354(91)90097-A
- Rossini M, Garcia Garrido J, Galluzzo M. Optimization of the coagulation-flocculation treatment: Influence of rapid mix parameters. Water Res. 1999;33:1817-1826. https://doi.org/10.1016/S0043-1354(98)00367-4
- Park SM, Jun HB, Jung MS, Koo HM. Effects of velocity gradient and mixing time on particle growth in a rapid mixing tank. Water Sci. Technol. 2006;53:95-102.
- McCullagh P, Nelder JA. Generalized linear models. 2nd ed. New York: Chapman and Hall; 1989.
- Liley JB. Fitting size distributions to optical particle counter data. Aerosol Sci. Technol. 1992;17:84-92. https://doi.org/10.1080/02786829208959562
- Christian S, Mathias H, Bastian W, Arben J, Matthias B. Experimental study of electrostatically colloidal particles: Colloidal stability and charge reversal. J. Colloid Interf. Sci. 2011;358:62-67. https://doi.org/10.1016/j.jcis.2011.02.039
- Lopez-Garcia JJ, Arandra-Rascon MJ, Grosse C, Horno J. Electrokinetics of charged colloidal particles taking into account the effect on ion size constraints. J. Colloid Interf. Sci. 2011;356:325-330. https://doi.org/10.1016/j.jcis.2010.12.063
- Ranran M, Yan W, Bo Z, Weiying X, Min D, Baoyu G. Impact of enhanced coagulation ways on flocs properties and membrane fouling: Increasing dosage and applying new composite coagulant. Desalination 2013;314:161-168. https://doi.org/10.1016/j.desal.2013.01.012