References
- R. Yao et al., "Small-animal PET what is it, and why do we need it?," J. Nucl. Med. Techno, Vol. 40, pp. 157-165, May 2012. https://doi.org/10.2967/jnmt.111.098632
- P. D. Cutler et al., "Design features and performance of a PET system for animal research," Journal of Nuclear Medicine Vol. 33, pp. 595-604, April 1992.
- M. Watanabe et al., "A high resolution PET for animal studies" IEEE Trans. Med. Imag. Vol. 11, no. 4, pp. 577-580, December 1992. https://doi.org/10.1109/42.192694
- S. R. Cherry et al., "MicroPET a high resolution PET scanner for imaging small animals," IEEE Trans. Nucl. Sci. Vol. 44, no. 3, pp. 1161-1166, Jun 1997. https://doi.org/10.1109/23.596981
- M. Bergeron et al., "Performance evaluation of the LabPET APD-based digital PET scanner," IEEE Trans. Nucl. Sci. Vol. 56, no. 1, pp 10-16, February 2009. https://doi.org/10.1109/TNS.2008.2010257
- H. W. de Jong et al., "Performance evaluation of the ECAT HRRT an LSO-LYSO double layer high resolution, high sensitivity scanner," Phys. Med. Biol. Vol. 52, no. 4, pp. 1505-1526, February 2007. https://doi.org/10.1088/0031-9155/52/5/019
- Y. Wang et al., "Performance evaluation of the GE Healthcare eXplore VISTA dual-ring small-animal PET scanner," J. Nucl. Med. Vol. 47, no. 11, pp. 1891-1900, November 2006.
- J. Seidel et al., "Resolution uniformity and sensitivity of the NIH ATLAS small animal PET scanner comparison to simulated LSO scanners without depth-of-interaction capability," IEEE Trans. Nucl. Sci. Vol. 50, no. 5, pp. 1347-1350, October 2003. https://doi.org/10.1109/TNS.2003.817282
- S. Surti et al., "Design evaluation of A-PET a high sensitivity animal PET camera," IEEE Trans.Nucl. Sci. Vol. 50, no. 5, pp. 1357-1363, October 2003. https://doi.org/10.1109/TNS.2003.817950
- K. Ziemonsa et al., "The ClearPETTM project development of a 2nd generation high-performance small animal PET scanner," Nucl. Instrum. Methods Phys. Res. A Vol. 537, no. 1-2, pp. 307-311, January 2005. https://doi.org/10.1016/j.nima.2004.08.032
- H. Peng et al., "Recent developments in PET," Instrumentation Curr Pharm Biotechnol. vol. 11, no. 6, pp. 555-571, July 2010. https://doi.org/10.2174/138920110792246555
- S.R. Cherry et al., Physics in Nuclear Medicine 3rd ed. (Saunders) pp. 334-336, 2003
- J. Zhang et al., "Study of the performance of a novel 1 mm resolution dual-panel PET camera design dedicated to breast cancer imaging using Monte Carlo simulation," Med. Phys. Vol. 34, no. 2, pp. 689-702, 2007. https://doi.org/10.1118/1.2409480
- T. Tsuda et al., "A four-layer depth of interaction detector block for small animal PET," IEEE Trans. Nucl. Sci. Vol. 51, no. 5, pp. 2537-2542, October 2004. https://doi.org/10.1109/TNS.2004.835739
- Y.H. Chung et al., "Performance measurements of a depth-encoding TraPET detector module," Jinst. Vol. 6 C11032, November 2011. https://doi.org/10.1088/1748-0221/6/11/C11032
- M. Ito et al., "Continuous depth-of-interaction measurement in a single-layer pixelated crystal array using a single-ended readout." Phys. Med. Biol. Vol. 58, no. 5, pp. 1269-1282, 2013. https://doi.org/10.1088/0031-9155/58/5/1269
- Y. H. Chung et al., "Preliminary experimental results of a quasi-monolithic detector with DOI capability for a small animal PET," Nucl. Instrum. Methods Phys. Res. A, Vol. 621, no. 1-3, pp. 590-594, September 2010. https://doi.org/10.1016/j.nima.2010.04.039
- Y.H. Chung et al., "TraPET High performance small animal PET with trapezoidal phoswich detector," Nucl. Instrum. Methods Phys. Res. A Vol. 652, pp. 802-805, October 2011. https://doi.org/10.1016/j.nima.2010.09.090
- M Ito et al., "Positron Emission Tomography (PET) Detectors with Depth-of-Interaction (DOI) Capability," Biomed Eng Lett. Vol. 1, no. 2, pp. 70-81, May 2011. https://doi.org/10.1007/s13534-011-0019-6
- Y. Shao et al., "A novel method to calibrate DOI function of a PET detector with a dual-endedscintillator readout," Med. Phys. Vol. 35, no. 12, pp.5829-5840, 2008. https://doi.org/10.1118/1.3021118
- A. Kishimoto et al., "Development of a dual-sided readout DOI-PET module using large-area monolithic MPPC-arrays," IEEE Trans Nucl Sci. Vol. 60, pp.38-43, 2013. https://doi.org/10.1109/TNS.2012.2233215
- M.C. Abreu et al., "Design and evaluation of the clear-PEM scanner for positron emission mammography," IEEE Trans. Nucl. Sci. Vol. 53, no. 1, pp. 71-77, February 2006. https://doi.org/10.1109/TNS.2006.870173
- Y. Yang et al., "A prototype PET scanner with DOIencoding detectors," J. Nucl. Med vol. 49, pp. 1132-1140, July 2008. https://doi.org/10.2967/jnumed.107.049791
- M. Ito et al., "Design and simulation of a novel method for determining depth-of-interaction in a PET scintillation crystal array using a single-ended rea-dout by a multi-anode PMT," Phys. Med. Biol. Vol. 55, no.13, pp. 3827-3841, 2010. https://doi.org/10.1088/0031-9155/55/13/017
- T.K. Lewellen et al., "Recent developments in PET detector technology," Phys. Med. Biol. Vol. 53, no.17, pp. R287-317, August 2008. https://doi.org/10.1088/0031-9155/53/17/R01
- H. Du et al., "Comparison of four depth-encoding PET detector modules with wavelength shifting (WLS) and optical fiber read-out," Phys. Med. Biol. Vol. 53, no. 7, pp. 1829-1842, March 2008. https://doi.org/10.1088/0031-9155/53/7/002
- S. Jan et al., "GATE a simulation toolkit for PET and SPECT," Phys. Med. Biol. Vol. 49, pp. 4543-4561, September 2004. https://doi.org/10.1088/0031-9155/49/19/007
- GATE User Guide.
- GE-Suinsa. Madrid (Spain).
- Gamma Medica-Ideas. Northridge, CA.
- Raytest GmbH. Straubenhardt (Germany).