DOI QR코드

DOI QR Code

Analysis of time to failure of orthodontic mini-implants after insertion or loading

  • Jeong, Jong-Wha (Department of Orthodontics, School of Dentistry and Dental Research Institute, Seoul National University) ;
  • Kim, Jong-Wan (Department of Orthodontics, Section of Dentistry, Seoul National University Bundang Hospital) ;
  • Lee, Nam-Ki (Department of Orthodontics, Section of Dentistry, Seoul National University Bundang Hospital) ;
  • Kim, Young-Kyun (Department of Oral and Maxillofacial Surgery, Section of Dentistry, Seoul National University Bundang Hospital) ;
  • Lee, Jong-Ho (Department of Oral and Maxillofacial Surgery and Oral Cancer Center, School of Dentistry and Dental Research Institute, Seoul National University Dental Hospital) ;
  • Kim, Tae-Woo (Department of Orthodontics, School of Dentistry and Dental Research Institute, Seoul National University)
  • Received : 2015.04.08
  • Accepted : 2015.06.26
  • Published : 2015.10.31

Abstract

Objectives: This study was performed to evaluate patterns of failure time after insertion, failure rate according to loading time after insertion, and the patterns of failure after loading. Materials and Methods: A total of 331 mini-implants were classified into the non-failure group (NFG) and failure group (FG), which was divided into failed group before loading (FGB) and failed group after loading (FGA). Orthodontic force was applied to both the NFG and FGA. Failed mini-implants after insertion, ratio of FGA to NFG according to loading time after insertion, and failed mini-implants according to failed time after loading were analyzed. Results: Percentages of failed mini-implants after insertion were 15.79%, 36.84%, 12.28%, and 10.53% at 4, 8, 12, and 16 weeks, respectively. Mini-implant failure demonstrated a peak from 4 to 5 weeks after insertion. The failure rates according to loading time after insertion were 13.56%, 8.97%, 11.32%, and 5.00% at 4, 8, 12, and 16 weeks, respectively. Percentages of failed mini-implants after loading were 13.79%, 24.14%, 20.69%, and 6.9% at 4, 8, 12, and 16 weeks, respectively. Conclusion: Mini-implant stability is typically acquired 12 to 16 weeks after insertion, and immediate loading can cause failure of the mini-implant. Failure after loading was observed during the first 12 weeks.

Keywords

References

  1. Suh HY, Lee SJ, Park HS. Use of mini-implants to avoid maxillary surgery for Class III mandibular prognathic patient: a long-term post-retention case. Korean J Orthod 2014;44:342-9. https://doi.org/10.4041/kjod.2014.44.6.342
  2. Kanomi R. Mini-implant for orthodontic anchorage. J Clin Orthod 1997;31:763-7.
  3. Lee HJ, Lee KS, Kim MJ, Chun YS. Effect of bite force on orthodontic mini-implants in the molar region: finite element analysis. Korean J Orthod 2013;43:218-24. https://doi.org/10.4041/kjod.2013.43.5.218
  4. Herrmann I, Lekholm U, Holm S, Kultje C. Evaluation of patient and implant characteristics as potential prognostic factors for oral implant failures. Int J Oral Maxillofac Implants 2005;20:220-30.
  5. Lee JH, Choo H, Kim SH, Chung KR, Giannuzzi LA, Ngan P. Replacing a failed mini-implant with a miniplate to prevent interruption during orthodontic treatment. Am J Orthod Dentofacial Orthop 2011;139:849-57. https://doi.org/10.1016/j.ajodo.2009.08.032
  6. Wiechmann D, Meyer U, Buchter A. Success rate of mini- and micro-implants used for orthodontic anchorage: a prospective clinical study. Clin Oral Implants Res 2007;18:263-7. https://doi.org/10.1111/j.1600-0501.2006.01325.x
  7. Kim JS, Choi SH, Cha SK, Kim JH, Lee HJ, Yeom SS, et al. Comparison of success rates of orthodontic mini-screws by the insertion method. Korean J Orthod 2012;42:242-8. https://doi.org/10.4041/kjod.2012.42.5.242
  8. Kim SH, Lee SJ, Cho IS, Kim SK, Kim TW. Rotational resistance of surface-treated mini-implants. Angle Orthod 2009;79:899-907. https://doi.org/10.2319/090608-466.1
  9. Grunder U. Immediate functional loading of immediate implants in edentulous arches: two-year results. Int J Periodontics Restorative Dent 2001;21:545-51.
  10. Kim YK, Kim BS, Yun PY, Mun SU, Yi YJ, Kim SG, et al. The seven-year cumulative survival rate of Osstem implants. J Korean Assoc Oral Maxillofac Surg 2014;40:68-75. https://doi.org/10.5125/jkaoms.2014.40.2.68
  11. Ioannidou E, Doufexi A. Does loading time affect implant survival? A meta-analysis of 1,266 implants. J Periodontol 2005;76:1252-8. https://doi.org/10.1902/jop.2005.76.8.1252
  12. Catharino PC, Dominguez GC, Pinto Ddos S Jr, Morea C. Histologic, histomorphometric, and radiographic monitoring of bone healing around in-office-sterilized orthodontic mini-implants with or without immediate load: study in rabbit tibiae. Int J Oral Maxillofac Implants 2014;29:321-30. https://doi.org/10.11607/jomi.2842
  13. Robling AG, Niziolek PJ, Baldridge LA, Condon KW, Allen MR, Alam I, et al. Mechanical stimulation of bone in vivo reduces osteocyte expression of Sost/sclerostin. J Biol Chem 2008;283:5866-75. https://doi.org/10.1074/jbc.M705092200
  14. Klein-Nulend J, van der Plas A, Semeins CM, Ajubi NE, Frangos JA, Nijweide PJ, et al. Sensitivity of osteocytes to biomechanical stress in vitro. FASEB J 1995;9:441-5. https://doi.org/10.1096/fasebj.9.5.7896017
  15. Forwood MR. Inducible cyclo-oxygenase (COX-2) mediates the induction of bone formation by mechanical loading in vivo. J Bone Miner Res 1996;11:1688-93.
  16. Tatsumi S, Ishii K, Amizuka N, Li M, Kobayashi T, Kohno K, et al. Targeted ablation of osteocytes induces osteoporosis with defective mechanotransduction. Cell Metab 2007;5:464-75. https://doi.org/10.1016/j.cmet.2007.05.001
  17. Kim YK, Ahn KJ, Yun PY, Kim M, Yang HS, Yi YJ, et al. Effect of loading time on marginal bone loss around hydroxyapatite-coated implants. J Korean Assoc Oral Maxillofac Surg 2013;39:161-7. https://doi.org/10.5125/jkaoms.2013.39.4.161
  18. Rebaudi A, Laffi N, Benedicenti S, Angiero F, Romanos GE. Microcomputed tomographic analysis of bone reaction at insertion of orthodontic mini-implants in sheep. Int J Oral Maxillofac Implants 2011;26:1233-40.
  19. Raghavendra S, Wood MC, Taylor TD. Early wound healing around endosseous implants: a review of the literature. Int J Oral Maxillofac Implants 2005;20:425-31.
  20. Atsumi M, Park SH, Wang HL. Methods used to assess implant stability: current status. Int J Oral Maxillofac Implants 2007;22:743-54.
  21. Al-Sawai AA, Labib H. Success of immediate loading implants compared to conventionally-loaded implants: a literature review. J Investig Clin Dent 2015. doi: 10.1111/jicd.12152. [Epub ahead of print]
  22. Romanos G, Grizas E, Laukart E, Nentwig GH. Effects of early moderate loading on implant stability: a retrospective investigation of 634 implants with platform switching and morse-tapered connections. Clin Implant Dent Relat Res 2015. doi: 10.1111/cid.12314. [Epub ahead of print]
  23. Kim YK, Kim JH, Yi YJ, Kwon MJ, Yun PY. Prospective comparative study of tapered implants with SLA surfaces in the maxillary posterior area according to 3- and 6-month loading time. Int J Periodontics Restorative Dent 2015;35:271-6. https://doi.org/10.11607/prd.1789
  24. Ramazanzadeh BA, Fatemi K, Dehghani M, Mohtasham N, Jahanbin A, Sadeghian H. Effect of healing time on bone-implant contact of orthodontic micro-implants: a histologic study. ISRN Dent 2014. doi: 10.1155/2014/179037.
  25. Lee SJ, Ahn SJ, Lee JW, Kim SH, Kim TW. Survival analysis of orthodontic mini-implants. Am J Orthod Dentofacial Orthop 2010;137:194-9. https://doi.org/10.1016/j.ajodo.2008.03.031
  26. Kim SH, Cho JH, Chung KR, Kook YA, Nelson G. Removal torque values of surface-treated mini-implants after loading. Am J Orthod Dentofacial Orthop 2008;134:36-43. https://doi.org/10.1016/j.ajodo.2006.07.038
  27. Kim JW, Ahn SJ, Chang YI. Histomorphometric and mechanical analyses of the drill-free screw as orthodontic anchorage. Am J Orthod Dentofacial Orthop 2005;128:190-4. https://doi.org/10.1016/j.ajodo.2004.01.030

Cited by

  1. Repeated failure of implants at the same site: a retrospective clinical study vol.41, pp.None, 2015, https://doi.org/10.1186/s40902-019-0209-1
  2. Repeated failure of implants at the same site: a retrospective clinical study vol.41, pp.None, 2015, https://doi.org/10.1186/s40902-019-0209-1
  3. RANK/RANKL/OPG gene polymorphisms and loss of orthodontic mini‐implants vol.23, pp.2, 2020, https://doi.org/10.1111/ocr.12360
  4. Effect of 808 nm Semiconductor Laser on the Stability of Orthodontic Micro-Implants: A Split-Mouth Study vol.13, pp.10, 2015, https://doi.org/10.3390/ma13102265
  5. A Clinical Trial of Photobiomodulation Effect on Orthodontic Microscrews Stability Using a 635 nm Red Laser Light vol.38, pp.10, 2015, https://doi.org/10.1089/photob.2020.4863