References
- Glasson JH, Guthrie LH, Nielsen DJ, Bethell FA. Evaluation of an automated instrument for inoculating and spreading samples onto agar plates. J Clin Microbiol 2008;46:1281-4. https://doi.org/10.1128/JCM.01687-07
- Weinstein MP, Murphy JR, Reller LB, Lichtenstein KA. The clinical significance of positive blood cultures: a comprehensive analysis of 500 episodes of bacteremia and fungemia in adults. II. Clinical observations, with special reference to factors influencing prognosis. Rev Infect Dis 1983;5:54-70. https://doi.org/10.1093/clinids/5.1.54
- Bourbeau PP and Ledeboer NA. Automation in clinical microbiology. J Clin Microbiol 2013;51:1658-65. https://doi.org/10.1128/JCM.00301-13
- Bourbeau PP and Swartz BL. First evaluation of the WASP, a new automated microbiology plating instrument. J Clin Microbiol 2009;47:1101-6. https://doi.org/10.1128/JCM.01963-08
- Mutters NT, Hodiamont CJ, de Jong MD, Overmeijer HP, van den Boogaard M, Visser CE. Performance of Kiestra total laboratory automation combined with MS in clinical microbiology practice. Ann Lab Med 2014;34:111-7. https://doi.org/10.3343/alm.2014.34.2.111
- Mischnik A, Mieth M, Busch CJ, Hofer S, Zimmermann S. First evaluation of automated specimen inoculation for wound swab samples by use of the Previ Isola system compared to manual inoculation in a routine laboratory: finding a cost-effective and accurate approach. J Clin Microbiol 2012;50:2732-6. https://doi.org/10.1128/JCM.05501-11
- King GW, Kath GS, Siciliano S, Simpson N, Masurekar P, Sigmund J, et al. Automated agar plate streaker: a linear plater on Society for Biomolecular Sciences standard plates. J Biomol Screen 2006;11:704-11. https://doi.org/10.1177/1087057106289288
- Van Horn KG, Audette CD, Tucker KA, Sebeck D. Comparison of 3 swab transport systems for direct release and recovery of aerobic and anaerobic bacteria. Diagn Microbiol Infect Dis 2008;62:471-3. https://doi.org/10.1016/j.diagmicrobio.2008.08.004
- Kist M, Bockemuhl J, Aleksic S, Altwegg M, Autenrieth IB, Bar W, et al. Infektionen des Darms. In: Mauch H, Lutticken R, et al., eds. Qualitatsstandards in der mikrobiologisch-infektiologischen Diagnostik. Munchen, Jena: Urban & Fischer, 2000:32-9.
- Tilton RC and Ryan RW. Evaluation of an automated agar plate streaker. J Clin Microbiol 1978;7:298-304.
-
Nebbad-Lechani B, Emirian A, Maillebuau F, Mahjoub N, Fihman V, Legrand P, et al. New procedure to reduce the time and cost of broncho-pulmonary specimen management using the Previ Isola
$^{(R)}$ automated inoculation system. J Microbiol Methods 2013;95:384-8. https://doi.org/10.1016/j.mimet.2013.10.013 - Tan KE, Ellis BC, Lee R, Stamper PD, Zhang SX, Carroll KC. Prospective evaluation of a matrix-assisted laser desorption ionization-time of flight mass spectrometry system in a hospital clinical microbiology laboratory for identification of bacteria and yeasts: a bench-by-bench study for assessing the impact on time to identification and cost-effectiveness. J Clin Microbiol 2012;50:3301-8. https://doi.org/10.1128/JCM.01405-12
- Fitzenberger J, Uphoff H, Gawrich S, Hauri AM. Urban-rural differences of age- and species-specific campylobacteriosis incidence, Hesse, Germany, July 2005-June 2006. Euro Surveill 2010;15. pii: 19693.
- Robert-Koch-Institut. Epidemiologie der Kryptokokkose in Deutschland von 2004 bis 2010. Epid Bull 2012;29:275. http://www.rki.de/DE/Content/Infekt/EpidBull/Archiv/2012/Ausgaben/29_12.pdf?__blob=publicationFile.
- European Centre for Disease Prevention and Control (ECDC). Annual epidemiological report. Reporting on 2011 surveillance data and 2012 epidemic intelligence data. Stockholm: ECDC, 2013.
- Marcus R, Rabatsky-Ehr T, Mohle-Boetani JC, Farley M, Medus C, Shiferaw B, et al. Dramatic decrease in the incidence of Salmonella serotype Enteritidis infections in 5 FoodNet sites: 1996-1999. Clin Infect Dis 2004;38(S3):S135-41. https://doi.org/10.1086/381579
- Funke G, Kunert T, Barth B, Fulchiron C, Bossy G. New automated solution for plate streaking: comparative evaluation of the PREVI Isola in a microbiology lab. 19th European Congress of Clinical Microbiology and Infectious Diseases. Abstract number, P887. Helsinki, 2009. http://www.lbtinnovations.com/assets/Uploads/eccmid092l.pdf (Updated on May 2009).
Cited by
- NUEVAS TECNOLOGÍAS EN DIAGNÓSTICO MICROBIOLÓGICO: AUTOMATIZACIÓN Y ALGUNAS APLICACIONES EN IDENTIFICACIÓN MICROBIANA Y ESTUDIO DE SUSCEPTIBILIDAD vol.26, pp.6, 2015, https://doi.org/10.1016/j.rmclc.2015.11.004
- Next-generation sequencing diagnostics of bacteremia in septic patients vol.8, pp.1, 2016, https://doi.org/10.1186/s13073-016-0326-8
- Next-generation sequencing diagnostics of bacteremia in sepsis (Next GeneSiS-Trial) : Study protocol of a prospective, observational, noninterventional, multicenter, clinical trial vol.97, pp.6, 2015, https://doi.org/10.1097/md.0000000000009868
- Manual versus automated streaking system in clinical microbiology laboratory: Performance evaluation of Previ Isola for blood culture and body fluid samples vol.32, pp.5, 2015, https://doi.org/10.1002/jcla.22373
- Laboratory Automation in Clinical Microbiology vol.5, pp.4, 2015, https://doi.org/10.3390/bioengineering5040102
- Enhanced Performance of Next-Generation Sequencing Diagnostics Compared With Standard of Care Microbiological Diagnostics in Patients Suffering From Septic Shock vol.47, pp.5, 2015, https://doi.org/10.1097/ccm.0000000000003658
- Next-generation sequencing diagnostics of bacteremia in pediatric sepsis vol.100, pp.25, 2015, https://doi.org/10.1097/md.0000000000026403