Abstract

Background: The bacterium Chlamydia trachomatis is one of the leading causes of sexually transmitted diseases worldwide. Since no simple and effective tool exists to diagnose C. trachomatis infections, we evaluated a novel point-of-care (POC) test, aQcare Chlamydia TRF kit, which uses europium-chelated nanoparticles and a time-resolved fluorescence reader. Methods: The test performance was evaluated by comparing the results obtained using the novel POC testing kit with those obtained using a nucleic acid amplification test (NAAT), using 114 NAAT-positive and 327 NAAT-negative samples. Results: The cut-off value of the novel test was 20.8 with a detection limit of 0.27 ng/mL. No interference or cross-reactivity was observed. Diagnostic accuracy showed an overall sensitivity of 93.0% (106/114), specificity of 96.3% (315/327), positive predictive value (PPV) of 89.8% (106/118), and negative predictive value (NPV) of 97.5% (315/323). The sensitivity of the novel test was much higher than that of currently available POC tests. Furthermore, the relative ease and short turnaround time (30 min) of this assay enables C. trachomatis-infected individuals to be treated without a diagnostic delay. Conclusions: This simple and novel test is a potential tool to screen a larger population, especially those in areas with limited resources.

Keywords

Acknowledgement

Supported by : MOTIE/KIAT

References

  1. Lee IS. Historical Changes and the Present Situation of Sexually Transmitted Diseases. J Korean Med Assoc 2008;51:868-74. https://doi.org/10.5124/jkma.2008.51.10.868
  2. Watson EJ, Templeton A, Russell I, Paavonen J, Mardh PA, Stary A, et al. The accuracy and efficacy of screening tests for Chlamydia trachomatis: a systematic review. J Med Microbiol 2002;51:1021-31. https://doi.org/10.1099/0022-1317-51-12-1021
  3. Torrone EA, Geisler WM, Gift TL, Weinstock HS. Chlamydia trachomatis infection among women 26 to 39 yr of age in the United States, 1999 to 2010. Sex Transm Dis 2013;40:335-7. https://doi.org/10.1097/OLQ.0b013e31827cd60d
  4. Korenromp EL, Sudaryo MK, de Vlas SJ, Gray RH, Sewankambo NK, Serwadda D, et al. What proportion of episodes of gonorrhoea and Chlamydia becomes symptomatic? Int J STD AIDS 2002;13:91-101. https://doi.org/10.1258/0956462021924712
  5. Patel AL, Sachdev D, Nagpal P, Chaudhry U, Sonkar SC, Mendiratta SL, et al. Prevalence of Chlamydia infection among women visiting a gynaecology outpatient department: evaluation of an in-house PCR assay for detection of Chlamydia trachomatis. Ann Clin Microbiol Antimicrob 2010;9:24. https://doi.org/10.1186/1476-0711-9-24
  6. Hajikhani B, Motellaebi T, Norouzi J, Bahador A, Bagheri R, Asgari S, et al. Classical and molecular methods for evaluation of Chlamydia trachomatis infection in women with tubal factor infertility. J Reprod Infertil 2013;14:29-33.
  7. Sachdeva P, Patel AL, Sachdev D, Ali M, Mittal A, Saluja D. Comparison of an in-house PCR assay, direct fluorescence assay and the Roche AMPLICOR Chlamydia trachomatis kit for detection of C. trachomatis. J Med Microbiol 2009;58:867-73. https://doi.org/10.1099/jmm.0.008698-0
  8. Saison F, Mahilum-Tapay L, Michel CE, Buttress ND, Nadala EC Jr, Magbanua JP, et al. Prevalence of Chlamydia trachomatis infection among low- and high-risk Filipino women and performance of Chlamydia rapid tests in resource-limited settings. J Clin Microbiol 2007;45: 4011-7. https://doi.org/10.1128/JCM.01343-07
  9. Michel CE, Saison FG, Joshi H, Mahilum-Tapay LM, Lee HH. Pitfalls of internet-accessible diagnostic tests: inadequate performance of a CE-marked Chlamydia test for home use. Sex Transm Infect 2009;85:187-9. https://doi.org/10.1136/sti.2008.035055
  10. Moi H. Handilab C Chlamydia for home testing is not what it claims. Tidsskr Nor Laegeforen 2007;127:2083-5.
  11. van Dommelen L, van Tiel FH, Ouburg S, Brouwers EE, Terporten PH, Savelkoul PH, et al. Alarmingly poor performance in Chlamydia trachomatis point-of-care testing. Sex Transm Infect 2010;86:355-9. https://doi.org/10.1136/sti.2010.042598
  12. von Lode P, Rosenberg J, Pettersson K, Takalo H. A europium chelate for quantitative point-of-care immunoassays using direct surface measurement. Anal Chem 2003;75:3193-201. https://doi.org/10.1021/ac0340051
  13. Wang Q, Nchimi Nono K, Syrjanpaa M, Charbonniere LJ, Hovinen J, Harma H. Stable and highly fluorescent europium (III) chelates for time-resolved immunoassays. Inorg Chem 2013;52:8461-6. https://doi.org/10.1021/ic400384f
  14. Xia X, Xu Y, Ke R, Zhang H, Zou M, Yang W, et al. A highly sensitive europium nanoparticle-based lateral flow immunoassay for detection of chloramphenicol residue. Anal Bioanal Chem 2013;405:7541-4. https://doi.org/10.1007/s00216-013-7210-9
  15. Xia X, Xu Y, Zhao X, Li Q. Lateral flow immunoassay using europium chelate-loaded silica nanoparticles as labels. Clin Chem 2009;55:179-82.
  16. CLSI. User protocol for evaluation of qualitative test performance; approved guideline-second edition. CLSI document EP12-2A. Wayne, PA: Clinical and Laboratory Standards Institute, 2008.
  17. CLSI. Protocols for determination of limits of detection and limits of quantitation; approved guideline-second edition. CLSI document EP17. Wayne, PA: Clinical and Laboratory Standards Institute, 2004.
  18. CLSI. Interference testing in clinical chemistry; approved guideline-second edition. CLSI document EP07-A2. Wayne, PA: Clinical and Laboratory Standards Institute, 2005.
  19. Juntunen E, Myyrylainen T, Salminen T, Soukka T, Pettersson K. Performance of fluorescent europium (III) nanoparticles and colloidal gold reporters in lateral flow bioaffinity assay. Anal Biochem 2012;428:31-8. https://doi.org/10.1016/j.ab.2012.06.005
  20. Zhou Y, Xia X, Xu Y, Ke W, Yang W, Li Q. Application of europium (III) chelates-bonded silica nanoparticle in time-resolved immunofluorometric detection assay for human thyroid stimulating hormone. Anal Chim Acta 2012;722:95-9. https://doi.org/10.1016/j.aca.2012.01.065
  21. Jarvenpaa ML, Kuningas K, Niemi I, Hedberg P, Ristiniemi N, Pettersson K, et al. Rapid and sensitive cardiac troponin I immunoassay based on fluorescent europium (III)-chelate-dyed nanoparticles. Clin Chim Acta 2012;414:70-5. https://doi.org/10.1016/j.cca.2012.08.027
  22. van der Helm JJ, Sabajo LO, Grunberg AW, Morre SA, Speksnijder AG, de Vries HJ. Point-of-care test for detection of urogenital Chlamydia in women shows low sensitivity. A performance evaluation study in two clinics in Suriname. PLoS One 2012;7:e32122. https://doi.org/10.1371/journal.pone.0032122
  23. Knox J, Tabrizi SN, Miller P, Petoumenos K, Law M, Chen S, et al. Evaluation of self-collected samples in contrast to practitioner-collected samples for detection of Chlamydia trachomatis, Neisseria gonorrhoeae, and Trichomonas vaginalis by polymerase chain reaction among women living in remote areas. Sex Transm Dis 2002;29:647-54. https://doi.org/10.1097/00007435-200211000-00006
  24. Huang W, Gaydos CA, Barnes MR, Jett-Goheen M, Blake DR. Comparative effectiveness of a rapid point-of-care test for detection of Chlamydia trachomatis among women in a clinical setting. Sex Transm Infect 2013;89:108-14. https://doi.org/10.1136/sextrans-2011-050355
  25. Mahilum-Tapay L, Laitila V, Wawrzyniak JJ, Lee HH, Alexander S, Ison C, et al. New point of care Chlamydia Rapid Test--bridging the gap between diagnosis and treatment: performance evaluation study. BMJ 2007;335:1190-4. https://doi.org/10.1136/bmj.39402.463854.AE
  26. Nadala EC, Goh BT, Magbanua JP, Barber P, Swain A, Alexander S, et al. Performance evaluation of a new rapid urine test for Chlamydia in men: prospective cohort study. BMJ 2009;339:b2655. https://doi.org/10.1136/bmj.b2655

Cited by

  1. A Fluorescence Immunochromatographic Assay Using Europium (III) Chelate Microparticles for Rapid, Quantitative and Sensitive Detection of Creatine Kinase MB vol.26, pp.3, 2015, https://doi.org/10.1007/s10895-016-1786-3
  2. A Systematic Review of Point of Care Testing for Chlamydia trachomatis , Neisseria gonorrhoeae , and Trichomonas vaginalis vol.2016, pp.None, 2015, https://doi.org/10.1155/2016/4386127
  3. Combination with antimicrobial peptide lyses improves loop-mediated isothermal amplification based method for Chlamydia trachomatis detection directly in urine sample vol.16, pp.None, 2015, https://doi.org/10.1186/s12879-016-1674-0
  4. Understanding Negative Predictive Value of Diagnostic Tests Used in Clinical Practice : vol.36, pp.1, 2015, https://doi.org/10.1097/dcc.0000000000000219
  5. Rapid Detection of Avian Influenza Virus by Fluorescent Diagnostic Assay using an Epitope-Derived Peptide vol.7, pp.7, 2015, https://doi.org/10.7150/thno.18857
  6. Point-of-Care Diagnostics: Recent Developments in a Connected Age vol.89, pp.1, 2015, https://doi.org/10.1021/acs.analchem.6b04630
  7. Strategies for overcoming challenges for decentralised diagnostics in resource-limited and catastrophe settings vol.17, pp.2, 2015, https://doi.org/10.1080/14737159.2017.1273773
  8. Rapid and Sensitive Lateral Flow Immunoassay Method for Procalcitonin (PCT) Based on Time-Resolved Immunochromatography vol.17, pp.3, 2017, https://doi.org/10.3390/s17030480
  9. Improvement of a rapid diagnostic application of monoclonal antibodies against avian influenza H7 subtype virus using Europium nanoparticles vol.7, pp.None, 2017, https://doi.org/10.1038/s41598-017-08328-9
  10. Systematic reviews of point-of-care tests for the diagnosis of urogenitalChlamydia trachomatisinfections vol.93, pp.suppl4, 2017, https://doi.org/10.1136/sextrans-2016-053067
  11. Development of a Rapid Fluorescent Immunochromatographic Test to Detect Respiratory Syncytial Virus vol.19, pp.10, 2018, https://doi.org/10.3390/ijms19103013
  12. Clinical evaluation of rapid fluorescent diagnostic immunochromatographic test for influenza A virus (H1N1) vol.8, pp.None, 2015, https://doi.org/10.1038/s41598-018-31786-8
  13. Inorganic Complexes and Metal-Based Nanomaterials for Infectious Disease Diagnostics vol.119, pp.2, 2015, https://doi.org/10.1021/acs.chemrev.8b00136
  14. Assessing the Reliability of Commercially Available Point of Care in Various Clinical Fields vol.12, pp.1, 2015, https://doi.org/10.2174/1874944501912010342
  15. The microbial threat: Can rare earths help? vol.13, pp.9, 2015, https://doi.org/10.1002/jbio.202000068
  16. Schnelltestdiagnostik sexuell übertragbarer Infektionen : Gemeinsame Stellungnahme von DSTIG, RKI, PEI sowie den Referenzzentren für HIV, HBV und HCV und Konsiliarlaboren für Chlamydien vol.63, pp.10, 2015, https://doi.org/10.1007/s00103-020-03218-4
  17. Recent Advances and New Challenges in Cisgender Women’s Gynecologic and Obstetric Health in the Context of HIV vol.64, pp.3, 2021, https://doi.org/10.1097/grf.0000000000000627
  18. Rapid Monitoring of Vancomycin Concentration in Serum Using Europium (III) Chelate Nanoparticle-Based Lateral Flow Immunoassay vol.9, pp.None, 2015, https://doi.org/10.3389/fchem.2021.763686