Acknowledgement
Supported by : MOTIE/KIAT
References
- Lee IS. Historical Changes and the Present Situation of Sexually Transmitted Diseases. J Korean Med Assoc 2008;51:868-74. https://doi.org/10.5124/jkma.2008.51.10.868
- Watson EJ, Templeton A, Russell I, Paavonen J, Mardh PA, Stary A, et al. The accuracy and efficacy of screening tests for Chlamydia trachomatis: a systematic review. J Med Microbiol 2002;51:1021-31. https://doi.org/10.1099/0022-1317-51-12-1021
- Torrone EA, Geisler WM, Gift TL, Weinstock HS. Chlamydia trachomatis infection among women 26 to 39 yr of age in the United States, 1999 to 2010. Sex Transm Dis 2013;40:335-7. https://doi.org/10.1097/OLQ.0b013e31827cd60d
- Korenromp EL, Sudaryo MK, de Vlas SJ, Gray RH, Sewankambo NK, Serwadda D, et al. What proportion of episodes of gonorrhoea and Chlamydia becomes symptomatic? Int J STD AIDS 2002;13:91-101. https://doi.org/10.1258/0956462021924712
- Patel AL, Sachdev D, Nagpal P, Chaudhry U, Sonkar SC, Mendiratta SL, et al. Prevalence of Chlamydia infection among women visiting a gynaecology outpatient department: evaluation of an in-house PCR assay for detection of Chlamydia trachomatis. Ann Clin Microbiol Antimicrob 2010;9:24. https://doi.org/10.1186/1476-0711-9-24
- Hajikhani B, Motellaebi T, Norouzi J, Bahador A, Bagheri R, Asgari S, et al. Classical and molecular methods for evaluation of Chlamydia trachomatis infection in women with tubal factor infertility. J Reprod Infertil 2013;14:29-33.
- Sachdeva P, Patel AL, Sachdev D, Ali M, Mittal A, Saluja D. Comparison of an in-house PCR assay, direct fluorescence assay and the Roche AMPLICOR Chlamydia trachomatis kit for detection of C. trachomatis. J Med Microbiol 2009;58:867-73. https://doi.org/10.1099/jmm.0.008698-0
- Saison F, Mahilum-Tapay L, Michel CE, Buttress ND, Nadala EC Jr, Magbanua JP, et al. Prevalence of Chlamydia trachomatis infection among low- and high-risk Filipino women and performance of Chlamydia rapid tests in resource-limited settings. J Clin Microbiol 2007;45: 4011-7. https://doi.org/10.1128/JCM.01343-07
- Michel CE, Saison FG, Joshi H, Mahilum-Tapay LM, Lee HH. Pitfalls of internet-accessible diagnostic tests: inadequate performance of a CE-marked Chlamydia test for home use. Sex Transm Infect 2009;85:187-9. https://doi.org/10.1136/sti.2008.035055
- Moi H. Handilab C Chlamydia for home testing is not what it claims. Tidsskr Nor Laegeforen 2007;127:2083-5.
- van Dommelen L, van Tiel FH, Ouburg S, Brouwers EE, Terporten PH, Savelkoul PH, et al. Alarmingly poor performance in Chlamydia trachomatis point-of-care testing. Sex Transm Infect 2010;86:355-9. https://doi.org/10.1136/sti.2010.042598
- von Lode P, Rosenberg J, Pettersson K, Takalo H. A europium chelate for quantitative point-of-care immunoassays using direct surface measurement. Anal Chem 2003;75:3193-201. https://doi.org/10.1021/ac0340051
- Wang Q, Nchimi Nono K, Syrjanpaa M, Charbonniere LJ, Hovinen J, Harma H. Stable and highly fluorescent europium (III) chelates for time-resolved immunoassays. Inorg Chem 2013;52:8461-6. https://doi.org/10.1021/ic400384f
- Xia X, Xu Y, Ke R, Zhang H, Zou M, Yang W, et al. A highly sensitive europium nanoparticle-based lateral flow immunoassay for detection of chloramphenicol residue. Anal Bioanal Chem 2013;405:7541-4. https://doi.org/10.1007/s00216-013-7210-9
- Xia X, Xu Y, Zhao X, Li Q. Lateral flow immunoassay using europium chelate-loaded silica nanoparticles as labels. Clin Chem 2009;55:179-82.
- CLSI. User protocol for evaluation of qualitative test performance; approved guideline-second edition. CLSI document EP12-2A. Wayne, PA: Clinical and Laboratory Standards Institute, 2008.
- CLSI. Protocols for determination of limits of detection and limits of quantitation; approved guideline-second edition. CLSI document EP17. Wayne, PA: Clinical and Laboratory Standards Institute, 2004.
- CLSI. Interference testing in clinical chemistry; approved guideline-second edition. CLSI document EP07-A2. Wayne, PA: Clinical and Laboratory Standards Institute, 2005.
- Juntunen E, Myyrylainen T, Salminen T, Soukka T, Pettersson K. Performance of fluorescent europium (III) nanoparticles and colloidal gold reporters in lateral flow bioaffinity assay. Anal Biochem 2012;428:31-8. https://doi.org/10.1016/j.ab.2012.06.005
- Zhou Y, Xia X, Xu Y, Ke W, Yang W, Li Q. Application of europium (III) chelates-bonded silica nanoparticle in time-resolved immunofluorometric detection assay for human thyroid stimulating hormone. Anal Chim Acta 2012;722:95-9. https://doi.org/10.1016/j.aca.2012.01.065
- Jarvenpaa ML, Kuningas K, Niemi I, Hedberg P, Ristiniemi N, Pettersson K, et al. Rapid and sensitive cardiac troponin I immunoassay based on fluorescent europium (III)-chelate-dyed nanoparticles. Clin Chim Acta 2012;414:70-5. https://doi.org/10.1016/j.cca.2012.08.027
- van der Helm JJ, Sabajo LO, Grunberg AW, Morre SA, Speksnijder AG, de Vries HJ. Point-of-care test for detection of urogenital Chlamydia in women shows low sensitivity. A performance evaluation study in two clinics in Suriname. PLoS One 2012;7:e32122. https://doi.org/10.1371/journal.pone.0032122
- Knox J, Tabrizi SN, Miller P, Petoumenos K, Law M, Chen S, et al. Evaluation of self-collected samples in contrast to practitioner-collected samples for detection of Chlamydia trachomatis, Neisseria gonorrhoeae, and Trichomonas vaginalis by polymerase chain reaction among women living in remote areas. Sex Transm Dis 2002;29:647-54. https://doi.org/10.1097/00007435-200211000-00006
- Huang W, Gaydos CA, Barnes MR, Jett-Goheen M, Blake DR. Comparative effectiveness of a rapid point-of-care test for detection of Chlamydia trachomatis among women in a clinical setting. Sex Transm Infect 2013;89:108-14. https://doi.org/10.1136/sextrans-2011-050355
- Mahilum-Tapay L, Laitila V, Wawrzyniak JJ, Lee HH, Alexander S, Ison C, et al. New point of care Chlamydia Rapid Test--bridging the gap between diagnosis and treatment: performance evaluation study. BMJ 2007;335:1190-4. https://doi.org/10.1136/bmj.39402.463854.AE
- Nadala EC, Goh BT, Magbanua JP, Barber P, Swain A, Alexander S, et al. Performance evaluation of a new rapid urine test for Chlamydia in men: prospective cohort study. BMJ 2009;339:b2655. https://doi.org/10.1136/bmj.b2655
Cited by
- A Fluorescence Immunochromatographic Assay Using Europium (III) Chelate Microparticles for Rapid, Quantitative and Sensitive Detection of Creatine Kinase MB vol.26, pp.3, 2015, https://doi.org/10.1007/s10895-016-1786-3
- A Systematic Review of Point of Care Testing for Chlamydia trachomatis , Neisseria gonorrhoeae , and Trichomonas vaginalis vol.2016, pp.None, 2015, https://doi.org/10.1155/2016/4386127
- Combination with antimicrobial peptide lyses improves loop-mediated isothermal amplification based method for Chlamydia trachomatis detection directly in urine sample vol.16, pp.None, 2015, https://doi.org/10.1186/s12879-016-1674-0
- Understanding Negative Predictive Value of Diagnostic Tests Used in Clinical Practice : vol.36, pp.1, 2015, https://doi.org/10.1097/dcc.0000000000000219
- Rapid Detection of Avian Influenza Virus by Fluorescent Diagnostic Assay using an Epitope-Derived Peptide vol.7, pp.7, 2015, https://doi.org/10.7150/thno.18857
- Point-of-Care Diagnostics: Recent Developments in a Connected Age vol.89, pp.1, 2015, https://doi.org/10.1021/acs.analchem.6b04630
- Strategies for overcoming challenges for decentralised diagnostics in resource-limited and catastrophe settings vol.17, pp.2, 2015, https://doi.org/10.1080/14737159.2017.1273773
- Rapid and Sensitive Lateral Flow Immunoassay Method for Procalcitonin (PCT) Based on Time-Resolved Immunochromatography vol.17, pp.3, 2017, https://doi.org/10.3390/s17030480
- Improvement of a rapid diagnostic application of monoclonal antibodies against avian influenza H7 subtype virus using Europium nanoparticles vol.7, pp.None, 2017, https://doi.org/10.1038/s41598-017-08328-9
- Systematic reviews of point-of-care tests for the diagnosis of urogenitalChlamydia trachomatisinfections vol.93, pp.suppl4, 2017, https://doi.org/10.1136/sextrans-2016-053067
- Development of a Rapid Fluorescent Immunochromatographic Test to Detect Respiratory Syncytial Virus vol.19, pp.10, 2018, https://doi.org/10.3390/ijms19103013
- Clinical evaluation of rapid fluorescent diagnostic immunochromatographic test for influenza A virus (H1N1) vol.8, pp.None, 2015, https://doi.org/10.1038/s41598-018-31786-8
- Inorganic Complexes and Metal-Based Nanomaterials for Infectious Disease Diagnostics vol.119, pp.2, 2015, https://doi.org/10.1021/acs.chemrev.8b00136
- Assessing the Reliability of Commercially Available Point of Care in Various Clinical Fields vol.12, pp.1, 2015, https://doi.org/10.2174/1874944501912010342
- The microbial threat: Can rare earths help? vol.13, pp.9, 2015, https://doi.org/10.1002/jbio.202000068
- Schnelltestdiagnostik sexuell übertragbarer Infektionen : Gemeinsame Stellungnahme von DSTIG, RKI, PEI sowie den Referenzzentren für HIV, HBV und HCV und Konsiliarlaboren für Chlamydien vol.63, pp.10, 2015, https://doi.org/10.1007/s00103-020-03218-4
- Recent Advances and New Challenges in Cisgender Women’s Gynecologic and Obstetric Health in the Context of HIV vol.64, pp.3, 2021, https://doi.org/10.1097/grf.0000000000000627
- Rapid Monitoring of Vancomycin Concentration in Serum Using Europium (III) Chelate Nanoparticle-Based Lateral Flow Immunoassay vol.9, pp.None, 2015, https://doi.org/10.3389/fchem.2021.763686