Abstract
The headed studs used extensively for steel-composite construction are specified as SS400 in the current Korean Standard specification considering the welding condition. And the corresponding equation for the shear force calculation is limited for the use of compression strength of concrete below $300kgf/cm^2$. However, it is expected that the high strengthening and precasting of both steel and concrete due to the necessity of shear connector or other connecting material for the combination of steel and concrete. Therefore, the experimental results obtained during the development process of high strength stud for the connection of high strength concrete and the steel member are reported in this paper. Also the effectiveness of newly developed shear connector using pipe(pipe stud) to increase the stiffness of a stud is verified by comparing both the stiffness and the strength with common stud bolt through the welding ability, mechanical characteristics and experimental investigation.
합성보의 쉬어코넥트로 널리 사용되고 있는 스터드볼트는 현재 학회규준에 강재의 재질은 용접성을 고려한 SS400이 규정되어 있으며, 그 전단내력의 산정식은 압축강도 $300kgf/cm^2$ 이하의 콘크리트를 대상으로 하고 있다. 한편 합성구조의 보급에 따라 합성보 뿐만 아니라 다른 구조부분에서도 강재과 콘크리트를 결합하는 쉬어코넥트 혹은 다른 용도의 접합재의 필요성과 함께 강재와 콘크리트의 고강도화, 프리캐스트화가 예상된다. 따라서 본 연구에서는 고강도 콘크리트와 강부재를 결합하기 위한 고강도 스터드의 개발을 목적으로 행하여진 일련의 실험결과를 보고하였다. 또한 스터드의 강성을 증대시키기 위한 강관을 이용한 쉬어콘넥트(이하, 파이프 스터드라고 한다)를 고안하였다. 본 논문에서는 고강도 스터드의 용접성, 역학특성에 관한 실험적 검토와 동시에 고강도 고강성 스터드인 파이프 스터드의 강성 내력을 종래의 스터드 볼트와의 비교실험을 하여 파이프 스터드의 유효성을 검증한다.