Abstract

Probabilistic safety assessment (PSA) has had a significant role in quantitative decision-making by finding design and operational vulnerabilities and evaluating cost-benefit in improving such weak points. In particular, it has been widely used as the core methodology for risk-informed applications (RIAs). Even though the nature of PSA seeks realistic results, there are still "conservative" aspects. One of the sources for the conservatism is the assumptions of safety analysis and the estimation of failure frequency. Surveillance, diagnosis, and prognosis (SDP), utilizing massive databases and information technology, is worth highlighting in terms of its capability for alleviating the conservatism in conventional PSA. This article provides enabling techniques to solidify a method to provide time- and condition-dependent risks by integrating a conventional PSA model with condition monitoring and prognostics techniques. We will discuss how to integrate the results with frequency of initiating events (IEs) and probability of basic events (BEs). Two illustrative examples will be introduced: (1) how the failure probability of a passive system can be evaluated under different plant conditions and (2) how the IE frequency for a steam generator tube rupture (SGTR) can be updated in terms of operating time. We expect that the proposed model can take a role of annunciator to show the variation of core damage frequency (CDF) depending on operational conditions.

Keywords

Acknowledgement

Supported by : Nuclear Safety and Security Commission (NSSC)

References

  1. A.L. Sousa, J.P. Duarte, P.L. Saldanha, P.F. Frutuoso e Melo, The Role of Risk-Informed Decision Making in the Licensing of Nuclear Power Plants, Risk Assessment and Management, Academy Publish, 2012. URL: http://www.academypublish.org/papers/pdf469.pdf.
  2. P.V. Varde, M.G. Pecht, Role of prognostics in support of integrated risk-based engineering in nuclear power plant safety, Int. J. Progn. Health Manag. 3 (1) (2012).
  3. J.B. Coble, R. Ramuhalli, L.J. Bond, J.W. Jines, B.R. Upadhyaya, Prognostics and Health Management in Nuclear Power Plants: A Review of Technologies and Applications, U. S. Department of Energy, PNNL-21515, Washington D.C., 2012.
  4. International Atomic Energy Agency Advanced Surveillance, Diagnostic and Prognostic Techniques in Monitoring Structures, Systems and Components in Nuclear Power Plants, IAEA Nuclear Energy Series NP-T-3.14, Vienna, 2013.
  5. J.W. Hines, R. Seibert, Technical Review of On-line Monitoring Techniques for Performance Assessment, vol. 1, State-of-the-Art, U.S. Nuclear Regulatory Commission, NUREG/CR-6895, Washington D.C., 2006.
  6. J.W. Hines, D. Garvey, R. Seibert, A. Usynin, Technical Review of On-line Monitoring Techniques for Performance Assessment, vol. 2-Theoretical Issues, U.S. Nuclear Regulatory Commission, NUREG/CR-6895, Washington D.C., 2008.
  7. J.W. Hines, D. Garvey, J. Garvey, R. Seibert, Technical Review of On-line Monitoring Techniques for Performance Assessment, vol. 3-Limiting Case Studies, U.S. Nuclear Regulatory Commission, NUREG/CR-6895, Washington D.C., 2008.
  8. International Atomic Energy Agency, Living Probabilistic Safety Assessment, IAEA-TECDOC-1106, Vienna, 1999.
  9. T. Aldemir, A survey of dynamic methodologies for probabilistic safety assessment of nuclear power plants, Ann. Nucl. Energy 52 (2013) 113-124. https://doi.org/10.1016/j.anucene.2012.08.001
  10. S. Poghosyan, A. Amirjanyan, "Risk-informed Prioirtization of Modernization Activities Using Ageing PSA Model", Probabilistic Safety Assessment and Management 12, 22-27 June 2014, pp. 22-27. Hawaii, 2014.
  11. R. Lewandowski, "Incorporation of Corrosion Mechanisms into a State-dependent Probabilistic Risk Assessment", Thesis, The Ohio State University, Ohio, 2013.
  12. M. Hashim, Y. Hidekazu, M. Takeshi, Y. Ming, Application case study of AP1000 automatic depressurization system (ADS) for reliability evaluation by GO-FLOW methodology, Nucl. Eng. Des. 278 (2014) 209-221. https://doi.org/10.1016/j.nucengdes.2014.06.040
  13. L.R. Rodrigues, T. Yoneyama, Maintenance Planning Optimization Based on PHM Information and Spare Parts Availability, Annual Conference of the Prognostics and Health Management Society, 14-17 October 2013, pp. 11-17. New Orleans Louisiana, 2013.
  14. B.P. Leao, Discrete Time Bayesian Estimation for Failure Prognosis, Annual Conference of the Prognostics and Health Management Society, 14-17 October 2013. Tutorials, New Orleans Louisiana, 2013.
  15. J. Jafari, F. D'Auria, H. Kazeminejad, H. Davilu, Reliability evaluation of a natural circulation system, Nucl. Eng. Design 224 (2003) 79-104. https://doi.org/10.1016/S0029-5493(03)00105-5
  16. E. Zio, G.E. Apostolakis, N. Pedroni, Quantitative functional failure analysis of a thermal-hydraulic passive system by means of bootstrapped artificial neural network, Ann. Nucl. Energy 37 (2010) 639-649. https://doi.org/10.1016/j.anucene.2010.02.012
  17. L.P. Pagani, G.E. Apostolakis, P. Hejzlar, The impact of uncertainties on the performance of passive systems, Nucl. Technol. 149 (2005) 129-140. https://doi.org/10.13182/NT149-129
  18. A.S.A. Shehhi, S.H. Chang, S.H. Kim, H.K. Kang, Analysis of economics and safety to cope with station blackout in PWR, Ann. Nucl. Energy 59 (2013) 63-71. https://doi.org/10.1016/j.anucene.2013.03.017
  19. S. Han, J. Yang, A quantitative evaluation of reliability of passive systems within probabilistic safety assessment framework for VHTR, Ann. Nucl. Energy 37 (2010) 345-358. https://doi.org/10.1016/j.anucene.2009.12.004
  20. Korea Atomic Energy Research Institute, Development and Hydraulic System Analysis Code MARS, Korea Atomic Energy Research Institute, KAERI/TR-3011/2005, Republic of Korea, 2005.
  21. J. Oh, "Methods for comparative assessment of active and passive safety systems with respect to reliability, uncertainty, economy, and Flexibility", Thesis, Department of Nuclear Science and Engineering, Massachusetts Institutes of Technology, 2008.
  22. U.S National regulatory Commission, Rates of Initiating Events at U.S. Nulcear Power Plants: 1987-1995, U.S. Nuclear Regulatory Commission, NUREG/CR-5750, Washington D.C., 1998.
  23. H. Cothron, Steam Generator Integrity Assessment Guideline, Electric Power Research Institue, EPRI Report No. 1019038 Rev. 3, California, 2009.
  24. H.S. Kim, H.J. Shim, C.K. Oh, S.G. Jung, Y.S. Chang, H.D. Kim, J.B. Lee, Development of Probabilistic Program for Structural Integrity Assessment of Steam Generator Tubes, The Korea Society of Mechanical Engineers Fall Annual Conference, Republic of Korea, Autumn 2012, pp. 477-481.
  25. J.B. Lee, J.H. Park, S.H. Lee, H.D. Kim, H.S. Chung, Statistical Estimation of Crack Growth Behavior in Steam Generator Tubes Using Monte Carlo Method, Proceedings of 18th International Conference on Structural Mechanics in Reactor Technology, August 2005, pp. 7-12. Beijing, China.

Cited by

  1. Accuracy Improvement of Boron Meter Adopting New Fitting Function and Multi-detector vol.48, pp.6, 2015, https://doi.org/10.1016/j.net.2016.06.012
  2. Some Challenges and Opportunities in Reliability Engineering vol.65, pp.4, 2015, https://doi.org/10.1109/tr.2016.2591504
  3. Improved Dynamic Dependability Assessment Through Integration With Prognostics vol.66, pp.3, 2015, https://doi.org/10.1109/tr.2017.2693821
  4. Dynamic Prediction for Accuracy Maintaining Reliability of Superprecision Rolling Bearing in Service vol.2018, pp.None, 2015, https://doi.org/10.1155/2018/7396293
  5. Prognostics for integrity of steam generator tubes using the general path model vol.50, pp.1, 2015, https://doi.org/10.1016/j.net.2017.10.006
  6. A Review of Methodologies for Safety and Hazard Management in Chemical Industries vol.5, pp.6, 2015, https://doi.org/10.1002/cben.201800010
  7. Application of particle filtering for prognostics with measurement uncertainty in nuclear power plants vol.50, pp.8, 2015, https://doi.org/10.1016/j.net.2018.08.002
  8. Development of accuracy enhancement system for boron meters using multisensitive detector for reactor safety vol.52, pp.3, 2015, https://doi.org/10.1016/j.net.2019.08.004