References
- H. Dirk Sostman, Paul D. Stein, Alexander Gottschalk, Fadi Matta, Russell Hull, MBBS, Larry Goodman, et al.: Acute pulmonary embolism : sensitivity and specificity of ventilation-perfusion scintigraphy in PIOPED II study. Radiology, 246(3), 941-946, 2008 https://doi.org/10.1148/radiol.2463070270
- Marie-Pierre Revel, StSphanie Cohen, Olivier Sanchez, Marie-Anne Collignon, Rokhaya Thiam, Alban Redheuil, Guy Meyer, et al.: Pulmonary embolism during pregnancy : diagnosis with lung scintigraphy or CT angiography? Radiology, 258(2), 590-598, 2011 https://doi.org/10.1148/radiol.10100986
- Susan Miles, Kerry M. Rogers, Paul Thomas, Barry Soans, John Attia, Christian Abel, Elizabeth Holt, Catherine A. D'Este, Michael J. Hensley: A comparison of single-photon emission CT lung scintigraphy and CT pulmonary angiography for the diagnosis of pulmonary embolism. Chest, 136(6), 1546-1553, 2009 https://doi.org/10.1378/chest.09-0361
- Pat Zanzonico, Micheal G. Stabin: Quantitative benefit-risk analysis of medical radiation exposures. Semin Nucl Med, 44(3), 210-214, 2014 https://doi.org/10.1053/j.semnuclmed.2014.03.010
- Malin Kjellberg, Karin Bjorkman, Malin Rohdin, Alejandro Sanchez-Crespo, Baldvin Jonsson: Bronchopulmonary dysplasia: Clinical grading in relation to ventilation/perfusion mismatch measured by single photon emission computed tomography. Pediatr Pulmonol, 48(12), 1206-1213, 2013 https://doi.org/10.1002/ppul.22751
- Chukwuemeka Onyedika, Joseph E. Glaser, Leonard M. Freeman: Pulmonary embolism: role of ventilationperfusion scintigraphy. Semin Nucl Med, 43(2), 82-87, 2013 https://doi.org/10.1053/j.semnuclmed.2012.11.002
- Stein PD., Freeman LM., Sostman HD., Goodman LR., Woodard PK., Naidich DP., Gottschalk A., Bailey DL., Matta F., Yaekoub AY., Hales CA., Hull RD., Leeper KV Jr., Tapson VF., Weg JG: SPECT in acute pulmonary embolism. J Nucl Med, 50(12), 1999-2007, 2009 https://doi.org/10.2967/jnumed.109.063958
- Pat Zanzonico: Principles of nuclear medicine imaging: planar, SPECT, PET, multi-modality, and autoradiography systems. Rad Research, 177(4), 349-364, 2012 https://doi.org/10.1667/RR2577.1
- Bajc M, Olsson CG, Olsson B, Palmer J, Jonson B: Diagnostic evaluation of planar and tomographic ventilation/perfusion lung images in patients with suspected pulmonary emboli. Clin Physiol Funct Imaging, 24(5), 249-256, 2004 https://doi.org/10.1111/j.1475-097X.2004.00546.x
- Alexandra Le Duc-Pennec, Pierre-Yves Le Roux, Jean Christophe Cornily, Morgan Jaffrelot, AurSlien Delluc, Luc de Saint-Martin, Philippe Guillo, GrSgoire Le Gal, Pierre-Yves Salaun, Christophe Leroyer: Diagnostic accuracy of single-photon emission tomography ventilation/perfusion lung Scan in the Diagnosis of Pulmonary Embolism. Chest, 141(2), 381-387, 2012 https://doi.org/10.1378/chest.11-0090
- Johan Petersson, Alejandro SSnchez-Crespo, Stig A. Larsson, Margareta Mure: Physiological imaging of the lung: single-photon-emission computed tomography (SPECT). J Applied Phys, 102(1), 468-476, 2007 https://doi.org/10.1152/japplphysiol.00732.2006
- Michel A. Meignan: Lung ventilation/perfusion SPECT: the right technique for hard times. J Nucl Med, 43(5), 648-651, 2002
- Paul J. Roach, Dale L. Bailey, Geoffrey P. Schembri: Reinventing ventilation/perfusion lung scanning with SPECT. Nucl Med Com, 29(12), 1023-1025, 2008 https://doi.org/10.1097/MNM.0b013e328315efa1
- Paul J. Roach, Geoffrey P. Schembri, Dale L. Bailey: V/Q scanning using SPECT and SPECT/CT. Nucl Med Com, 54(9), 1588-1596, 2013 https://doi.org/10.2967/jnumed.113.124602
- M. Bajc, J. B. Neilly, M. Miniati, C. Schuemichen, M. Meignan, B. Jonson: EANM guidelines for ventilation/perfusion scintigraphy. Eur J Nucl Med Mol Imaging, 36(9), 1528-1538, 2009 https://doi.org/10.1007/s00259-009-1169-y
- Pierre-Yves Le Roux, Xavier Palard, Philippe Robin, Aurelien Delluc, Ronan Abgral, Solene Querellou, Francis Couturaud, Gregoire Le Gal, Pierre-Yves Salaun: Safety of ventilation/perfusion single photon emission computed tomography for pulmonary embolism diagnosis. Eur J Nucl Med Mol Imaging, 41(10), 1957-1964. 2014 https://doi.org/10.1007/s00259-014-2763-1
- Jonas Jogi, Bjorn Jonson, Marie Ekberg, Marika Bajc: Ventilation-perfusion SPECT with 99mTc-DTPA versus technegas: A head-to-head study in obstructive and nonobstructive disease. J Nucl Med, 51(5), 735-741, 2010 https://doi.org/10.2967/jnumed.109.073957
- Bajc M, Olsson B, Palmer J, Jonson B: Ventilation/perfusion SPECT for diagnostics of pulmonary embolism in clinical practice. J Intern Med, 264(4), 379-387, 2008 https://doi.org/10.1111/j.1365-2796.2008.01980.x
- Sasaki Y, Imai T, Shinkai T, et al.: Estimation of regional lung function in interstitial pulmonary disease using 99mTc-technegas and 99mTc-MAA single-photon emission computed tomography. Eur J Nucl Med, 25(12), 1623-1629. 1998 https://doi.org/10.1007/s002590050340
- Blumenschein George R. Jr., Ciuleanu, Tudor, Robert Francisco, Groen Harry J. M., Usari, Tiziana, Ruiz-Garcia Ana Pharm, Tye Lesley, Chao Richard C., Juhasz Erzsebet: Sunitinib plus erlotinib for the treatment of advanced/metastatic non-small-cell lung cancer: a lead-in study. J Thorac Onc, 7(9), 1406-1416. 2012 https://doi.org/10.1097/JTO.0b013e31825cca1c
- Dale L. Bailey, Kathy P. Willowson: An evidence based review of quantitative SPECT imaging and potential clinical applications. J Nucl Med, 54(1), 83-89, 2013 https://doi.org/10.2967/jnumed.112.111476
- Laura K. Nason, Christopher M. Walker, Michael F. McNeeley, Wanaporn Burivong, Corinne L. Fligner, J. David Godwin: Imaging of the diaphragm: anatomy and function. Radio Graphics, 32(2), 51-70, 2012
- Daniel M. Adams, Scott M. Stevens, Scott C. Woller, R. Scott Evans, James F. Lloyd, Gregory L. Snow, Todd L. Lovelace, et al.: Adherence to PIOPED II investigator' recommendations for computed tomography pulmonary angiography. J Amc Med, 126(1), 36-42, 2013 https://doi.org/10.1016/j.amjmed.2012.05.028
- H. Drik Sostman, Massimo Miniati, Alexandra Gottschalk, Fadi Matta, Paul D. Stein, Massimo Pistolesi: Sensitivity and Specificity of Perfusion Scintigraphy Combined with Chest Radiography for Acute Pulmonary Embolism in PIOPED II. J Nucl Med, 49(11), 1741-1748, 2008 https://doi.org/10.2967/jnumed.108.052217
- Fessler HE, Talmor Ds: Should prone positioning be routinely used for lung protection during mechanical ventilation? Respir Care, 55(1), 88-99, 2010
- Mark T. Madsen: Recent advances in SPECT imaging, J Nucl Med., 48(4), 661-673, 2007 https://doi.org/10.2967/jnumed.106.032680
- Ryszkowski J, Noce TA, Vento JA: The clinical application of image fusion software to PET, SPECT, CT and MRI. Clin Nucl Med, 31(2), 114, 2006.
- Andreas K. Buck, Stephan Nekolla, Sibylle Ziegler, Ambros Beer, Bernd J. Krause, Ken Herrmann, Klemens Scheidhauer, Hans-Juergen Wester, Ernst J. Rummeny, et al.: SPECT/CT. J Nucl Med, 49(8), 1305-1319, 2008 https://doi.org/10.2967/jnumed.107.050195