DOI QR코드

DOI QR Code

Evaluation of Shear Strength of Perfobond Rib in Ultra High Performance Concrete

초고성능 콘크리트에 대한 Perfobond Rib 전단연결재 거동 평가

  • Kang, Jae-Yoon (Structural Engineering Research Institute, Korea Institute of Civil Engineering and Building Technology) ;
  • Jung, Woo-Tai (Structural Engineering Research Institute, Korea Institute of Civil Engineering and Building Technology)
  • 강재윤 (한국건설기술연구원 구조융합연구소) ;
  • 정우태 (한국건설기술연구원 구조융합연구소)
  • Received : 2015.06.05
  • Accepted : 2015.07.16
  • Published : 2015.07.31

Abstract

Push-out test is performed on perfobond shear connectors applying ultra high performance concretes with compressive strength higher than 80 MPa to evaluate their shear resistance. The test variables are chosen to be the diameter and number of dowel holes and, the change in the shear strength of the perfobond rib connector is examined with respect to the strength of two types of UHPC: steel fiber-reinforced concrete with compressive strength of 180 MPa and concrete without steel fiber with compressive strength of 80 MPa. The test results reveal that higher concrete strength and larger number of holes increased the shear strength, and that higher increase rate in the shear strength was achieved by the dowel action.

기존에 제안된 Perfobond rib connector의 강도평가식은 압축강도가 약 50 MPa 이하의 콘크리트 강도 범위에 대한 Push-out test의 결과로 유도된 것으로서, 압축강도 80 MPa 이상의 초고성능 콘크리트에 대한 전단 연결재 성능 평가를 위하여 Perfobond rib 연결재의 전단강도를 파악하기 위한 Push-out test를 수행하였다. Perfobond rib connector의 제작변수는 관통홀의 지름 및 개수이며, 강섬유가 혼입된 180 MPa의 콘크리와 강섬유를 혼입하지 않은 압축강도 80 MPa의 콘크리트를 적용하여 콘크리트 강도 변화에 대한 전단강도 변화를 검토하였다. 실험결과, 콘크리트 강도와 홀의 개수가 증가함 따라 전단강도가 증가하며, 다웰 효과에 의한 전단강도 증가율도 큰 것으로 나타났다. 기존에 다른 연구자들이 제안한 강도식으로 계산된 예측치와 비교한 결과, 실험값은 Oguejiofor & Hosain[2]이 제안한 강도식에 근접한 결과를 보였다.

Keywords

References

  1. AASHTO, AASHTO LRFD Bridge Design Specifications, 6th Edition, p.1635, Washington DC, US, 2012.
  2. BSI, BS EN 1994-1-1:2004: Eurocode 4: Design of composite steel and concrete structure, p.122, BSI, London UK, 2004.
  3. E. C. Oguejiofor, & M. U. Hosain, "A parametric study of perfobond rib shear connectors," Canadian Journal of Civil Engineering, Vol.21, No.4, pp.614-625, 1994. DOI: http://dx.doi.org/10.1139/l94-063
  4. G. S. Verissimo, M. I. B. Valente, J. L. R. Paes, P. J. S. Cruz, R. H. Fakury, "Design and experimental analysis of a new shear connector for steel and concrete composite structures," Proceedings of 3rd International Conference on Bridge Maintenance, Safety and Management, pp.68-72, 2006.
  5. J.-H. Ahn, C.-G. Lee, J.-H. Won, S.-H. Kim, "Shear resistance of the perfobond-rib shear connector depending on concrete strength and rib arrangement". J. Constr. Steel Res., Vol.66, No.10, pp.1295-1307, 2010. DOI: http://dx.doi.org/10.1016/j.jcsr.2010.04.008
  6. J.-R. Cho, S. Y. Park, K. Cho, S. T. Kim, & B.-S. Kim, "Pull-out test and discrete spring model of fibre-reinforced polymer perfobond rib shear connector," Canadian Journal of Civil Engineering, Vol.39, No.12, pp.1311-1320, 2012. DOI: http://dx.doi.org/10.1139/cjce-2011-0573
  7. S. B. Medberry, B. M. Shahrooz, "Perfobond shear connector for composite construction," AISC Chicago, No.1, pp.2-12, 2002.
  8. S. Y. K. Al-Darzi, A. R. Chen and Y. Q. Liu, "Finite Element Simulation and Parametric Studies of Perfobond Rib Connector," American Journal of Applied Sciences, Vol.4, pp.122-127, 2007. DOI: http://dx.doi.org/10.3844/ajassp.2007.122.127
  9. Y. Ushijima, T. Hosaka, K. Mitsuki, H. Watanabe, Y. Tachibana, H. Hiragi, "An experimental study on shear characteristics of perfobond strip and its rational strength equations," Proceedings of the International Symposium on Connections between Steel and Concrete, pp.1066-1075, 2001.