DOI QR코드

DOI QR Code

A Study on the PM10 and CO2 Concentrations at Public Places

일부 실내공간에서 PM10과 CO2의 농도 특성에 관한 연구

  • Jung, Joon-sig (Indoor air and noise Research division, National Institute of Environmental Research) ;
  • Park, Duckshin (Korea Railroad Research Institute) ;
  • Kim, Jong bum (GREEN SCHOOL(Graduate school of Energy and Environment), Korea university) ;
  • Song, Hyea-suk (Health administration, Kwangju Women's University) ;
  • Park, Hyung-kyu (Indoor air and noise Research division, National Institute of Environmental Research)
  • 정준식 (국립환경과학원 생활환경연구과) ;
  • 박덕신 (한국철도기술연구원) ;
  • 김종범 (고려대학교 그린스쿨) ;
  • 송혜숙 (광주여자대학교 보건행정학과) ;
  • 박형규 (국립환경과학원 생활환경연구과)
  • Received : 2015.03.23
  • Accepted : 2015.06.11
  • Published : 2015.06.30

Abstract

The objective of this study was to investigate $PM_{10}$ and $CO_2$ concentrations in the classrooms of 286 elementary schools in Suwon, Ansan, and Hwaseong in the province of Gyeonggi between August 2008 and December 2012. By gaining an understanding of the environmental factors that influence these concentrations, this study also aimed to establish a management plan for indoor air quality in schools, which substantially affects the health of elementary students. When the schools were classified by region, no statistically significant difference in $PM_{10}$ concentration was observed. However, $PM_{10}$ concentration was relatively high in industrial areas and low in rural areas. No difference in $CO_2$ concentration was observed among the surveyed cities. Analysis of annual $PM_{10}$ concentration showed that the highest values for Suwon and Hwaseong occurred in 2008 and 2009, respectively (p<0.01). In the case of Ansan, the highest concentration occurred during 2009, but the difference was not significant compared to the other years. Analysis of the annual $CO_2$ concentration of each city shows no significant difference among the cities (p-value=0.366,0.730,0.210). According to a time series analysis of $PM_{10}$ and $CO_2$ by season, from autumn 2008 to winter 2012, $PM_{10}$ concentration was high during 2009, then it gradually decreased until 2012, and started to increase again. While no difference in annual $CO_2$ concentration was observed, the concentration had a tendency to be higher in spring and winter than in summer. By analyzing the relationship between $PM_{10}$ and $CO_2$ and the environmental factors (years of construction, average students of classroom, temperature, and humidity), it showed a significant negative correlation was found between $CO_2$ and the environmental temperature and humidity, at -0.329 and -0.188, respectively (p<0.01).

본 연구에서는 2008년 8월부터 2012년 12월 까지 경기도 수원, 안산, 화성 등 초등학교 286곳을 대상으로 교실에서의 $PM_{10}$$CO_2$ 농도 현황을 조사하고, 환경적 특성을 파악하여 초등학교 학생들의 건강에 영향을 미치는 학교 실내공기질의 관리 방안으로 활용하고자 한다. 초등학교를 지역별로 구분하여 $PM_{10}$ 농도를 조사한 결과, 통계적으로 유의한 차이를 보이진 않았다. 그러나 지리적 특성에 따라 상대적으로 공단지역에서는 높은 농도를 보였으며, 농촌지역에서는 낮은 농도를 보였다. $CO_2$ 농도는 각 지역 간 농도 차이는 없는 것으로 나타났다. 연도별 $PM_{10}$ 농도를 분석한 결과, 수원은 2008년, 화성은 2009년에 가장 높은 농도로 나타났다(p<0.01). 안산지역은 2009년에 가장 높은 농도를 보였으나, 유의한 차이를 보이지 않았다. 각 지역 의 연도별 $CO_2$의 농도를 분석한 결과, 유의한 차이를 보이지 않는 것으로 분석 되었다(p-value = 0.366, 0.730, 0.210). 2008년 가을부터 2012년 겨울까지 $PM_{10}$$CO_2$의 계절별 시계열 분석 결과, $PM_{10}$의 경우는 2009년에 높게 나타났으며, 점차적으로 감소하는 경향을 보이다가 2012년에 다시 높아지는 경향을 보였다. $CO_2$는 연도별로 차이가 없는 것으로 나타났으나, 계절별로 는 봄과 겨울기간이 여름철보다 농도가 높아지는 경향을 나타내었다. $PM_{10}$$CO_2$, 건축년도, 학급 평균 인원, 온도, 습도와의 상관성을 분석한 결과, $CO_2$와 환경적 요인인 온도, 습도와 상관성은 각 -0.329, -0.188로 유의한 음의 상관성을 보였다(p< 0.01).

Keywords

References

  1. Sohn, J. R., Yoon, S. W., Kim, Y. S., Roh, Y. M., Lee, C. M., Son, B. S., Yang, W. H., Lee, Y. G., Choi, H. Y., Lee, J. S., "A survey on the indoor air quality of seoul school classrooms in korea." Journal of Korean Society for Indoor Environment, Vol.3, No.1, p. 54-63, 2006.
  2. Sohn, J. R., Roh, Y. M., Son, B. S. "The Assessment of Survey on the Indoor Air Quality at Schools in Korea." Korean Journal of Environmental and Health, Vol.32, No.2, p. 140-148, 2006b.
  3. Yang, W. H., Sohn, J. R., Kim, J., Son, B. S., Park, J. C., "Indoor air quality investigation according to age of the school buildings in Korea." Journal of Environmental Management, Vol.90, No.1, p.348-354, 2009. DOI: http://dx.doi.org/10.1016/j.jenvman.2007.10.003
  4. Shendell, D. G., Prill, R., Fisk, W. J., Apte, M. G., Blake, D., Faulkner, D., "Association between CO2 concentrations and student attendance in Washington Idaho." Indoor Air, Vol.14, p. 333-341, 2004. DOI: http://dx.doi.org/10.1111/j.1600-0668.2004.00251.x
  5. Meininghaus, R. A. Kouniali, C., Mandin, C., Cicolella, A., "Risk assessment of sensory irritants in indoor air-a case study in a French school." Environmental International, Vol.28, No.7, p. 553-557, 2003. DOI: http://dx.doi.org/10.1111/j.1600-0668.2004.00251.x
  6. Daisey, J. M., Angell, W. J., Apte, M .G., "Indoor air quality, ventilation and health symptoms in schools: an analysis of existion information." Indoor Air, Vol.13, No.1, p. 53-64, 2003. DOI: http://dx.doi.org/10.1034/j.1600-0668.2003.00153.x
  7. U.S Environmental Protection Agency (EPA). "Indoor air quality(IAQ) tool for school." IAQ coordinator's 2nd ed, EPA. 2000.
  8. Korea Ministry of Education, 2010. Science and Technology : School Law.
  9. Jung, J. H., Seo, B. S., Ju, D. J., Park, M. C., Shon, B. H., Phee, Y. G., "Assessment of the Indoor Air Quality at Schools in Ulsan." Korean Journal of Environmental and Health, Vol.36, No.6, p. 472-479, 2010. DOI: http://dx.doi.org/10.5668/JEHS.2010.36.6.472
  10. World Health Organization (WHO). "Effects of air pollution on children's health and development-a review of the evidence." 2005.
  11. Barnett, A. G., Williams, G. M., Schwartz, J., "Air pollution and child respiratory health: a case-crossover study in Australia and New Zealand." American Journal of Respiratory Critical Care Medicine, Vol.171, p. 1271-1278, 2005. DOI: http://dx.doi.org/10.1164/rccm.200411-1586OC
  12. Yang, W. H., Byeon, J. C., Kim, Y. H., Kim, D. W., Son, B. S., Lee, J. E., "Assessment of indoor air quality of classroom in school by means of source generation-case study." Journal of the Environmental Science, Vol.14, No.10, p. 979-983, 2005. https://doi.org/10.5322/JES.2005.14.10.979
  13. Kim, H. J.,, Kim, S. S., Lee, K. S.,, Jung, S. K.,, Cho, J. K., "A survey on the indoor air quality of some schools in goyang city." Journal of the Environmental Administration, Vol.15, No.2, p. 85-90, 2009.
  14. Seo, B. W., Lee J. H., Park, J. H., Kang, S. H., "Infant target facilities and facilities for children in elementary school comparison and improvement of indoor air quality for research." Journal of Korean Society of Water and Wastewater, Vol.27, No.5, p. 591-601, 2013. DOI: http://dx.doi.org/10.11001/jksww.2013.27.5.591
  15. Lee, C. S., Kim, H. H., Yu, S. D., Lee, J. S., Chang, J. Y., Gwak, Y. K., Son, H. R., Lim, Y. W., "A survey of distribution for environment exposure in the activities space of elementary school-Focused on PM10, PM2.5, Black Carbon, VOCs and Formaldehyde." Journal of Korean Society for Indoor Environment, Vol.10, No.4, p. 303-317, 2013.
  16. Roh, Y. M., Kim, J. C., Lee, C. M., Kim, Y. S., Ha, M. N., Kwon, H. J., Jeong, C. H., Paik, J. M., Kwon, Y. G., "A Survey of Distribution for Indoor Air Pollutants in Classrooms of Some Elementary Schools." Journal of Korean Society for Indoor Environment, Vol.4, No.4, 204-213, 2007.
  17. An, S. Y., Kim, M. G., Kim, O. S., Na, C. G., Lee, Y. J., Lee, C. W., Park, J. H., "A survey on the indoor air quality of some school classroom in Gyeongbuk area." Journal of Korean Society for Indoor Environment, Vol.3, No.4, p. 367-375, 2006.
  18. Cho, T. J., Chio, H. S., Jeon. Y. T., Lee, C. W., Lee, J. D., Jou, H. M., Son, B. S., "The study of indoor air quality at schools in chung-nam area." Journal of Environmental Sciences, Vol.17, No.5, p. 501-507, 2008. https://doi.org/10.5322/JES.2008.17.5.501
  19. Santamouris, M., Synnefa, A., Asssimakopoulos, M., Livada, I., Pavlou, K., Papaglastra, M., Gaitani, N., Kolokotsa, D., Assimakopoulos, V., "Experimental investigation of the air flow and indoor carbon dioxide concentration in classrooms with intermittent natural ventilation." Energy and Buildings, Vol.40, No.10, p. 1833-1843, 2008. DOI: http://dx.doi.org/10.1016/j.enbuild.2008.04.002
  20. Kim, S. K., Kim, J. O., Cho, C. Y., Kim, J. R., Son, J. H., "A study on the measurement and improving of indoor air quality in a educational facility." The journal of Korean Institute of Educational Facilities, Vol.14, No.4, p. 43-52, 2007.
  21. Kim, Y. P., "Analysis of the trend of atmospheric PM10 concentration over the seoul metropolitan area between 1999 and 2008." Korean Society of Environmental Assessment, Vol.19, No.1, p. 59-74, 2010.
  22. Jang, J. H., Lee, H. W., Lee, S. H., "Spatial and temporal features of PM10 evolution cycle in the korean peninsula." Journal of the Environmental Sciences, Vol.21, No.2, p. 189-202, 2012. DOI: http://dx.doi.org/10.5322/JES.2012.21.2.189
  23. Richard, A. W., Peter, A. S., "Indoor air pollution, A Wiley-Interscience Publication." 1983.
  24. Fromme, H., Twardella, D., Dietrich, S., Heitmann, D., Schierl, R., Liebl, B., Ruden, H., "Particulate matter in the indoor air of classrooms-exploratory results from Munich and surrounding area." Atmospheric Environment, Vol.41, No.4, p. 854-866, 2007. DOI: http://dx.doi.org/10.1016/j.atmosenv.2006.08.053
  25. Son, B. S., Song, M. R., Kim, J. D., Cho, T. J., Yang, W. H., Chung, T. W., "The study on concentration of PM10 and heavy metal in public schools at Chunag-Nam area." Journal of the Environmental Sciences, Vol.17, No.9, p. 1005-1013, 2008. https://doi.org/10.5322/JES.2008.17.9.1005
  26. Jung, J. W., Lee, H. K., "Improvement strategies for classroom IAQ in elementary schools." Proceeding of the 39th Meeting of KOSAE, p. 172-173, 2005.
  27. Poupard, O., Blondeau, P., Iordache, V., Allard F., "Statistical analysis of parameters influencing the relationship between outdoor and indoor air quality in schools." Atmospheric Environment, Vol.39, No.11, p. 2071-2080, 2005. DOI: http://dx.doi.org/10.1016/j.atmosenv.2004.12.016