초록

This study investigated the smoke blocking and control systems for the safety of residents evacuation and for the prevention of smoke spread through the central corridor in the event of central corridor type of intelligent building fire. We offered additional ways of utilizing smoke ventilators and intake ventilation equipment and utilized CFD-based fire simulation program(FDS Ver.5.5.3) in order to analyze the effect. As a result, many differences in the smoke block effect, depending on the application of smoke ventilator and location of installation, was found. In addition, the result was found that larger effect was showed not in the case of application of smoke ventilator in central corridor only but application in fire room. The reason is that the smoke leakage is blocked primarily as air is flowed in the fire room through open door by operation of intake smoke ventilator in the public corridor and secondarily, the smoke leakage to the public corridor could be blocked as fire and smoke were released to the opened smoke ventilator continuously. Especially, the effect was maximized through complex interactions by applying smoke ventilator and intake ventilation equipment in corridor together rather than applying smoke ventilator and intake ventilation equipment independently. The proposed measure through this study shall be considered from architectural plan as one of ways for blocking from smoke spread to the central corridor in the central corridor type of intelligent building. In addition, flaws on regulation shall be established and supplemented.

키워드

참고문헌

  1. Y.J. Bae and S.K Lee, (2009), "A Study Evacuation Appropriateness for the Residential Building by Simulation(FDS, Simulex)", Journal of Korean Association for Organization Studies, 52. pp. 1-2.
  2. S.U. Kim, (2005), "Building smoke control system", Journal of Korea Association of Air Conditioning Refrigerating and Sanitary Engineers, Vol. 22, No. 8, pp. 78-91.
  3. S. H. Min, (2012) "A Study on the Evacuation Risk of Simultaneous Fires from Exterior", Journal of Korean Institute of Fire Science & Engineering, Vol. 26, No. 4, pp. 48- 54.
  4. Y.J. Bae, (2012), "A Study on Preventing Spread of Smoke and Securing Safety of Evacuation in Central Core Type High-Rise Buildings", The Graduate School of Gachon University. pp. 1-35.
  5. National Emergency Management Agency, "Next Generation Fire Protection & Safety Core Technology Development Program(Performance evaluation and DB construction on medium-scale vertical fire)", pp. 313-423(2010).
  6. National Emergency Management Agency, "The report on the model for the prevention and reduction of spread of extensive demage in high-rise & complex building areas", (2010).
  7. J.S. Kim, (2001), "A Study on the Design method of Presurization System for Smoke Control", The Graduate School of Kyonggi University. pp. 1-35.
  8. NFSC 501, National Fire Safety Codes of Smoke Control System" National Emergency Management Agency (2012).
  9. http://www.nema.go.kr
  10. http://www.moleg.go.kr/main.html
  11. http://www.fire.nist.gov/fire/fires/kiosk/kisk.html

피인용 문헌

  1. Study of the Problems and Improvements of the Installation and Maintenance for Natural Smoke Ventilators in Buildings vol.30, pp.6, 2016, https://doi.org/10.7731/KIFSE.2016.30.6.118
  2. An Analysis on Research Trend Analysis on Construction Field for Smart Housing Vitalization in Korea : Focus on KCI Journals (2010~2020) vol.21, pp.5, 2015, https://doi.org/10.12813/kieae.2021.21.5.067