DOI QR코드

DOI QR Code

Analyses of Structural Performances for RC High-Rise Residential Complex Building under Construction

철근콘크리트 초고층 주상복합 건물의 시공 중 구조성능 분석

  • Hwang, Young-Jin (Department of Architectural Engineering, Kwangwoon Univ.) ;
  • Kim, Jae-Yo (Department of Architectural Engineering, Kwangwoon Univ.)
  • 황영진 (광운대학교 건축공학과) ;
  • 김재요 (광운대학교 건축공학과)
  • Received : 2014.07.02
  • Accepted : 2014.10.06
  • Published : 2015.02.28

Abstract

Recently, the most of domestic high-rise residential complex buildings are constructed with reinforced concrete structures, which may bring structural problems during construction. This study is aimed to analyze structural safety and lateral load-resisting performance of RC high-rise residential complex building under construction. The tower-typed building with 60 floors is selected as a sample model, and numerical analyses are performed. The structural performances of building structures at construction stages, which are resulted form the analyses of numerical models completed up to 10th, 20th, 30th, 40th, 50th, or 60th floor, are compared to those of the completed building structure. For the comparisons of structural performances, modal shapes and fundamental periods of building structures, lateral load-resisting performances, and structural design performances of structural members are considered. The lateral displacement and story drift ratio are analyzed for lateral load-resisting performances, and comparisons of design ratios at construction and design stages are performed for structural design performances of structural members. The guideline of design loads and structural analysis schemes for checking the safety of RC high-rise building under construction is presented.

근래 국내 초고층 주상복합 건물에는 철근콘크리트구조가 보편적으로 적용되는데, 이러한 철근콘크리트 초고층 주상복합 건물은 시공 시점에 따라 구조적인 문제가 발생할 수 있다. 따라서, 시공 중인 철근콘크리트 초고층 주상복합 건물에 대하여, 시공 시점별 구조 안전성 및 횡력저항성능을 검토하고자 한다. 이를 위해, 예제 모델로 탑상형의 초고층 주상복합 60층 건물을 선정했고, 기존의 범용구조해석 프로그램을 사용하여 구조해석을 수행하였다. 각 시공 시점별 10층, 20층, 30층, 40층, 50층, 60층 완료모델과 60층 완공단계 모델의 구조성능을 비교하였다. 구조성능 비교를 위해 이 모델들의 고유치해석을 수행하였으며, 횡력저항성능과 부재별 단면성능을 검토하였다. 횡력저항성능 검토를 위해 횡변위비와 층간변위비를 검토했고, 부재별 단면성능 검토는 완공단계에 대한 설계강도비와 시공단계의 설계강도비를 비교하여 부재안전성을 검토하였다. 이 연구를 통해, 시공 중인 철근콘크리트 초고층 건물의 구조 안전성을 검토하고 시공단계에 적합한 구조해석 및 설계하중의 가이드라인을 제시하고자 한다.

Keywords

References

  1. AIK (2009) Korean Building Code and Commentary, p.1039.
  2. AIK (2013) Korean Architectural Standard Specification, p.1784.
  3. ASCE 37-02 (2002) Design Loads on Structures During Construction, p.36.
  4. Choe, M.M., Eom, T.S., Kim, J.Y. (2013) An Analysis of Structural Behaviors during Construction for Twisted High-Rise Steel Buildings, J. Arch. Inst. Korea (Structure), 29(12), pp.45-53.
  5. Eom, T.S., Kim, J.Y. (2009) An Application of Construction Sequence Analysis for Checking Structural Stability of High-Rise Building under Construction, J. Comput. Struct. Eng. Inst. Korea, 22(3), pp.211-221.
  6. Ha, T.H., Lee, S.H., Tak, S.Y., Oh, B.H. (2011) Guideline for Building Movement during Construction of High-Rise Buildings, J. Korea Concr. Inst., pp.749-750.
  7. KCI (2012) Concrete Design Code and Commentary, p.600.
  8. KIM, H.S., Shin, S.H. (2010) Effects of Differential Column Shortening on Internal Member Forces of Tall Buildings, J. Arch. Insti. Korea (Structure), 26(5), pp.35-42.
  9. Kurc, O., Lulec, A. (2013) A Comparative Study on Different Analysis Approaches for Estimating the Axial Loads on Columns and Structual Walls at Tall Buildings, Struct. Design of Tall & Spec. Build., 22(6), pp.485-499. https://doi.org/10.1002/tal.699
  10. Kwak, H.G., Kim, K.J. (2006) Time-dependent Analysis of RC Frame Structures Considering Construction Sequences, Build. & Environ., 41(10), pp.1423-1434. https://doi.org/10.1016/j.buildenv.2005.05.013
  11. Lee, S.H., Ha, T.H., Tak, S.Y. (2013) Prediction of Lateral Deformation of Tall Building during Construction, J. Korea Concr. Inst., pp.73-74.
  12. Lee, Y.W., Kim, J.U. (2003) An Analysis of the Flat PlateStructure with Simplified Equivalent Beam Model, J. Arch. Inst. Korea (Structure), 19(11), pp.57-64.
  13. MIDAS IT (2013) MIDAS Structural Technical Lecture Series
  14. Jayasinghe, M.T.R., Jayasena, W.M.V.P.K. (2004) Effect of Axial Shortening of Columns on Design and Construction of Tall Reinforced Concrete Buildings, Pract. Period. Struct. Design & Constr., pp.70-78.
  15. Pan, L.B., Liu, P.C., Bakoss, S.L. (1993) Long-Term Shortening of Concrete Columns in Tall Buildings, J. Struct. Eng., 119(7), pp.2258-2262. https://doi.org/10.1061/(ASCE)0733-9445(1993)119:7(2258)
  16. Rosowsky, D.V. (1995) Estimation of Design Loads for Resuced Reference Periods, Struct. Safety, 17(1), pp.17-32. https://doi.org/10.1016/0167-4730(94)00037-Q