Analysis of the Impact of Floor Area Ratio on Heating Energy Demand by Passive Housing Complex

용적률이 패시브 공동주택 난방 에너지요구량에 미치는 영향 분석

  • Received : 2015.01.08
  • Accepted : 2015.05.13
  • Published : 2015.05.30

Abstract

This study compared and analyzed the difference in heating energy demand in relation to the raise of floor area ratio based on the case of passive housing complex based on the intention of examining whether relaxing floor area ratio as an incentive acknowledged when acquiring certification is a substantial system for realizing passive housing or zero energy housing complex and making related suggestions. The energy performance analysis on each building showed that the heating energy demand decreased, however, for buildings influenced by the increase of floors in the building before them, the energy demand increased as the solar heat gain decreased while the heat loss through conduction and ventilation and internal heating did not show difference. The combination analysis of 30 buildings showed that the total heating energy demand by the complex increased in proportion to the floor area ratio while the annual heating energy demand per unit area decreased. Since the difference in heating energy demand is directly related with the total energy consumption, it is necessary to consider the housing complex's energy performance in arranging and composing main buildings from the planning stage. Furthermore, it is necessary to make an additional suggestion for the energy efficiency rating based on the characteristics of the household as the heat loss and gain patterns appear variously according to such characteristics.

Keywords

Acknowledgement

Supported by : 국토교통부

References

  1. Choi, S., Kim, E., Hong, Y., & Kim, K. (2014) The Improvement Measures for the Energy Performance Certification System based on the Analysis of Actual Energy Consumption by Multi-unit Housing, Journal of the Architectural Institute of Korea, 34(1), 221-222.
  2. Chu, S., Cha, J., & Lee, M. (2013). Comparative Analysis on the Architectural Design Vocabulary in the Early Design Stage of Passive Houses, Journal of the Architectural Institute of Korea, Planning and Design Section, 29(6), 41-50.
  3. Kim, E. (2014). Development of a Solar Insolation Calculation Module in Urban Context Using the Sunlit Fraction and Sky-view Factor, Journal of the Architectural Institute of Korea, Planning and Design Section, 30(7), 229-236.
  4. Lewis, Sarah. (2015), PHPP illustrated : a designer's companion to the passive house planning package.
  5. Ministry of Land, Infrastructure and Transport (2009), Green Building Certification Criteria and Certification System Improvement of the Revitalization, 482-483.
  6. Hootman, Tom. (2013), Net Zero Energy Design, Spacetime Publisher.