DOI QR코드

DOI QR Code

A Parameter Study on the Shear Failure Behavior of Post-installed Set Anchor for Light Load

저하중용 후설치 세트앵커의 전단파괴거동에 관한 매개변수 연구

  • 엄찬희 (가톨릭관동대학교 토목공학과) ;
  • 유승운 (가톨릭관동대학교 토목공학과)
  • Received : 2014.04.10
  • Accepted : 2014.11.20
  • Published : 2015.05.30

Abstract

Post-installed concrete set anchors are installed after the concrete hardened. These anchors increasing usage in development of construction equipment and flexible construction. The anchor loaded in shearing exhibits various failure modes such as steel failure, concrete failure, concrete pryout, depending on the shear strength of steel, the strength of concrete, edge distance and anchor interval, etc,. In this study, the objective is to investigate the effects of the variations like anchor embedment depth, edge distance and concrete strength on experimental and finite element analysis of shear failure behavior of post-installed concrete set anchor for light load embedded in concrete. The results of embedment depth experiments show that concrete strength has much affection on the shallow embedment depth. Concrete strength has no much affection with anchor interval and edge distance parameter and both experimental results occurred same failure mode. By comparing the experimental results that occurred steel failure mode show that as strong as concrete strength are the displacement results are small.

콘크리트용 후설치 세트앵커는 콘크리트가 경화된 후에 설치되는 앵커이며 시공 장비의 발달과 시공의 유연성 및 용이성으로 사용량이 증가하고 있는 실정이다. 전단하중을 받는 앵커는 강재 파괴, 콘크리트 파열파괴, 콘크리트 프라이아웃 파괴 등의 대표적인 파괴모드를 보인다. 본 연구에서는 매입깊이, 연단거리 및 콘크리트 강도를 변수로 한 세트앵커의 실험 및 유한요소 해석 결과를 통하여 콘크리트에 매입된 저하중용 후설치 세트앵커의 전단 파괴거동에 미치는 영향을 규명하는 것을 그 목적으로 한다. 매입깊이 변수의 실험 결과 매입깊이가 얕을수록 콘크리트 강도의 영향이 큰 것으로 나타났다. 연단거리 변수의 실험 결과 동일한 파괴모드를 보이면서 콘크리트 강도의 영향이 크지 않은 것으로 나타났다. 강재 파괴가 발생한 실험 결과를 비교해 보았을 때 콘크리트 강도가 클수록 변위가 상대적으로 더 작게 나타났다.

Keywords

References

  1. ACI Committee 318 (2002), Building Code Requirements Structural Concrete and Commentary, American Concrete Institute.
  2. ACI Committee 349 (1990), Code Requirements for Nuclear Safety Related Concrete Structures (ACI 349-01); Appendix B Anchoring to Concrete, Detroit, 80-86.
  3. Jang, J. B., Suh, Y. P., and Lee, J. R. (2004), An Evaluation of Influence Factors to Shear Capacity of Cast-in-place Anchor, Proceedings of Conference on Korean Society of Civil Engineers, KSCE, 2283-2288.
  4. Jefferson, A. D. (2003), Craft-A Plastic-Damage-Contact Model for Concrete, I. Model Theory and Thermodynamic Considerations, Journal of Solids and Structures, 5973-5999.
  5. Kim, J. S., Kwon, M. H., Seo, H. S., and Park, J. H. (2013), Performance Evaluation and Analysis Model for the Post-Installed Anchor, Journal of Hazard Mitigation, KOSHAM, 13(2), 89-95.
  6. Kim, S. Y. (2003), Shear Strength of Anchors under Load Applied Angle and a Group Anchors at an Edge, Journal of Hazard Mitigation, KOSHAM, 3(3), 133-141.
  7. Kim, S. Y., Han, D. J., and Shin, C. H. (2005), Strength of Anchors under Load Applied Angles, Journal of Hazard Mitigation, KOSHAM, 5(1), 69-76.
  8. Ko, J. Y., Kim, S. Y., Kim, Y. H., Seo, S. Y., and Kim, K. S. (2002), Shear Strength of Single Anchors in Uncracked and Unreinforced Concrete, Proceedings of Annual Conference of the Architectural Institute of Korea, 197-200.
  9. Lee, K. M., Lee, C. Y., Jung, S. H., and Choi, S. W. (2009), Tensile and Shear Test Method for Post-installed Mechanical Anchors Embedded in Concrete, Proceedings of Magazine of the Korea Concrete Institute, KCI, 97-98.
  10. LUSAS (2013), Modeller User's Manual, FEA Ltd.
  11. Um, C. H., and Yoo, S. W. (2014), An Experimental Study on the Shear Failure Behavior of Post-installed Set Anchor for Concrete, Journal of Korean Society of Civil Engineers, KSCE, 34(1), 367-375. https://doi.org/10.12652/Ksce.2014.34.2.0367
  12. Werner, F., Rolf, E., and John, E. B. (1995), Concrete Capacity Design (CCD) Approach for Fastening to Concrete, ACI Structural Journal, 92(1), 73-94.