DOI QR코드

DOI QR Code

준평등전계중 Dry Air내 산소의 농도에 따른 절연파괴 및 연면방전 특성 연구

A Study on Characteristics of Insulation Breakdown and Surface Discharge by the Oxygen Concentration in the Dry Air in Quasi-Uniform Field

  • 투고 : 2015.07.06
  • 심사 : 2015.09.04
  • 발행 : 2015.11.30

초록

This study was conducted to discover a substitute of $SF_6$ gas. $SF_6$ gas is widely used across the industries. Thanks to superior electrical properties, in particular, it has been commonly used in electrical industry. However, there have been a lot of studies on its serious effect on global warming. As a substitute of this synthetic gas, a mixture of dry air and $N_2/O_2$ was chosen in this study. In case of $N_2/O_2$, dielectric strength differs depending on the mixing ratio. This study examined dielectric breakdown and flashover after adjusting oxygen percentage in the dry air. This test was conducted in a quasi-uniform electric field depending on pressure, oxygen concentration and gas mixtures. The test results found that dielectric voltage and flashover voltage were the highest at a certain oxygen concentration. It is the results of this photoionization and electron attachment of oxygen.

키워드

참고문헌

  1. S. H. Park, "European Union and the Kyoto Protocol", ACEF Autumn Anuual Conference 2008, pp. 125-144, 2008.
  2. L.G. Christophorou, J.K. Olthoff and R.J. Van Brunt, "Sulfur Hexafluoride and the Electric Power Industry", IEEE Electrical Insulation Magazine, Vol. 13, No. 5, pp. 20-24, September/October, 1997. https://doi.org/10.1109/57.620514
  3. T. Rokunohe, Y. Yagihashi, K. Aoyagi, T. Oomori and F. Endo, "Developrrent of $SF_6$-free 72.5 kV GIS", IEEE Trans. on Power Delivery, Vo1. 22, No. 3, pp. 1869-1876, July 2007. https://doi.org/10.1109/TPWRD.2007.899273
  4. X. Q. Qiu, I. D. Chalmers, P. Coventry,"A study of alternative insulating gases to $SF_6$", J. Phys. D: Appl. Phys., Vol. 32, pp. 2918-2922, 1999. https://doi.org/10.1088/0022-3727/32/22/314
  5. T. Rokunohe, Y. Yagihashi, F. Endo, and T. Oomori, "Fundamental Insulation Characteristics of Air, $N_2$, $CO_2$, $N_2$/$O_2$ and $SF_6$/$N_2$ Mixed Gases", Electrical Engineering in Japan, Vol. 155, No. 3, pp9-17, 2006. https://doi.org/10.1002/eej.20348
  6. T. Yoshida, H. Koga, T. Harada, S. Miki, M. Arioka, S. Sato, S. Yoshida, N. Inoue, A. Maruyama, and T. Takeuchi, "Insulation Technology in Dry-Air and Vacuum for a 72-kV Low-Pressure Dry-Air Insulated Switchgear", Electrical Engineering in Japan, Vol. 175, No. 1, 2011.
  7. H. Saito, K. Nagatake, H. Komatsu, Y. Takeshi, Y. Matsui, k. Katslmata, and M. Sakaki, "Development of 72/84-kV Dry Air-Insulated Dead Tank VCB",Electrical Engineering in Japan, Vol. 177, No. 1, 2011.
  8. D. Y. Lim, "A Study of Surface Insulation Characteristics in $N_2$/$O_2$ Mixture gas", a thesis submitted for the degree of master of Electrical Engineering, Yeungnam University, 2011.
  9. D. Y. Lim, "Comparative Study on Surface Insulation Performance in Oxygen/Nitrogen Gas Mixtures for High Voltage Equipment in Distribution Class", a thesis submitted for the degree of doctor of Electrical Engineering, Yeungnam University, 2015.
  10. K. C. Seo, "High Voltage Engineering (New edition)", Dong Myeong Publishers, pp.34-40 ,1977.
  11. J. H. Mason, "Discharges", IEEE Trans. Electr. Insul, Vol. EI-13, No. 4, pp. 211-238, August 1978. https://doi.org/10.1109/TEI.1978.298074