Abstract
A coil design of pulse induction metal detectors has been described. The search coil was demonstrated by using the wire with the diameter of 0.3 mm, 0.5 mm and 1.0 mm and the dielectric plate with the $30cm{\times}30cm$ and $35cm{\times}35cm$, the time constant and the currents of the coil as the variation of the coil size and the number of coil turns was characterized. The coil parameters like the resistance, the inductance and the time constants as the variation of the diameter of the wire, the coil size and the number of coil turns were compared and analysed through the calculation and the measurement. In addition, investigating the coil currents as the variation of the input pulse width, the coil design of pulse induction metal detectors has been discussed.
펄스 유도(Pulse Induction) 방식의 금속 탐지기 코일 설계에 대하여 살펴보았다. 0.3 mm, 0.5 mm, 1.0 mm의 직경을 갖는 도선과 $30cm{\times}30cm$ 및 $35cm{\times}35cm$ 크기의 유전체 탐지판을 이용하여 탐지 코일을 제작하였고, 코일 크기와 코일 감은 수 등의 파라미터 변화에 따른 코일 시정수 및 코일 전류 등의 특성을 살펴보았다. 도선의 직경, 코일 크기 및 코일 감은 수 변화에 따른 코일의 인덕턴스, 저항 및 시정수 값에 대하여 계산 결과와 측정 결과를 비교 분석하였다. 또한, 입력 펄스폭 변화에 따른 탐지 코일의 전류 변화에 대하여 계산 결과와 측정 결과를 비교 분석함으로써 펄스 유도 방식의 금속탐지기 코일 설계에 대하여 논하였다.