DOI QR코드

DOI QR Code

Review and Evaluation of Hand-Arm Coordinate Systems for Measuring Vibration Exposure, Biodynamic Responses, and Hand Forces

  • Dong, Ren G. (Engineering & Control Technology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health) ;
  • Sinsel, Erik W. (Engineering & Control Technology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health) ;
  • Welcome, Daniel E. (Engineering & Control Technology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health) ;
  • Warren, Christopher (Engineering & Control Technology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health) ;
  • Xu, Xueyan S. (Engineering & Control Technology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health) ;
  • McDowell, Thomas W. (Engineering & Control Technology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health) ;
  • Wu, John Z. (Engineering & Control Technology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health)
  • 투고 : 2015.03.30
  • 심사 : 2015.06.28
  • 발행 : 2015.09.30

초록

The hand coordinate systems for measuring vibration exposures and biodynamic responses have been standardized, but they are not actually used in many studies. This contradicts the purpose of the standardization. The objectives of this study were to identify the major sources of this problem, and to help define or identify better coordinate systems for the standardization. This study systematically reviewed the principles and definition methods, and evaluated typical hand coordinate systems. This study confirms that, as accelerometers remain the major technology for vibration measurement, it is reasonable to standardize two types of coordinate systems: a tool-based basicentric (BC) system and an anatomically based biodynamic (BD) system. However, these coordinate systems are not well defined in the current standard. Definition of the standard BC system is confusing, and it can be interpreted differently; as a result, it has been inconsistently applied in various standards and studies. The standard hand BD system is defined using the orientation of the third metacarpal bone. It is neither convenient nor defined based on important biological or biodynamic features. This explains why it is rarely used in practice. To resolve these inconsistencies and deficiencies, we proposed a revised method for defining the realistic handle BC system and an alternative method for defining the hand BD system. A fingertip-based BD system for measuring the principal grip force is also proposed based on an important feature of the grip force confirmed in this study.

키워드

피인용 문헌

  1. The Efficacy of Anti-vibration Gloves vol.44, pp.1, 2015, https://doi.org/10.1007/s40857-015-0040-5
  2. A description of hand matrices to extract various characteristics of human hand in three-dimensional space vol.37, pp.3, 2015, https://doi.org/10.1016/j.bbe.2017.05.003
  3. Biomechanical response of the human foot when standing in a natural position while exposed to vertical vibration from 10-200 Hz vol.62, pp.5, 2019, https://doi.org/10.1080/00140139.2018.1559362
  4. Effects of the vibrations of powered hand tools on users: A case study vol.18, pp.2, 2015, https://doi.org/10.5937/jaes18-22694
  5. Evaluation of the inter-rater and intra-rater reliability of a protocol for the measurement of foot-transmitted vibration vol.22, pp.2, 2015, https://doi.org/10.1080/1463922x.2020.1811922
  6. A Review of Hand-Arm Vibration Studies Conducted by US NIOSH since 2000 vol.4, pp.2, 2015, https://doi.org/10.3390/vibration4020030