References
- Malushte SR, Whittaker AS. Survey of past base isolation applications in nuclear power plants and challenges to industry regulatory acceptance. Proceedings of the 18th International Conference on Structural Mechanics in Reactor Technology Beijing, China; c2005. p.3404-3410.
- Kelly JM. The influence of base isolation on the seismic response of light secondary equipment. Report No. UCB/EERC-81/17. Earthquake Engineering Research Center, College of Engineering, University of California, Berkeley, CA. c1982.
- Kelly JM, Tsai HC. Seismic response of light internal equipment in base isolated structures. Report No. UCB/SESM-84/17. Division of Structural Engineering and Structural Mechanics, Department of Civil Engineering, College of Engineering, University of California, Berkeley, CA. c1984.
- Huang Y, Whittaker AS, Constantinou MC, Malushte S. Seismic Demands on Secondary Systems in Base-isolated Nuclear Power Plants. Earthquaek Engineering and Structural Dynamics. 2007;36:1741-171. https://doi.org/10.1002/eqe.716
- Zhou Z, Wong J, Mahin S. Vertical and 3D Isolation Systems: A Review with Emphasis on Their Use in Nuclear Structures. Transations, SMiRT-22. San Francisco, California, USA. c2013.
- Morishita M, Inoue K. Fujita T. Three Dimensional Seismic Isolation Technology for Nuclear Power Plant Application. 9th World Seminar on Seismic Isolation, Energy Dissipation and Active Vibration Control of Structures, Kobe, Japan. c2005; p.135-154.
- Warn GP, Whittaker AS, Constansinou MC. Vertical Stiffness of Elastomeric and Lead-Rubber Seismic Isolation Bearings. Journal of Structural Engineering, ASCE. 2007;133(9):1227-1236. https://doi.org/10.1061/(ASCE)0733-9445(2007)133:9(1227)
- Warn GP, Whittaker AS. Vertical Earthquake Load on Seismic Isolation Systems in Bridges. Journal of Structural Engineering, ASCE. c2008; p.1696-1704.
- Furukawa S, Sato E, Shi Y, Becker T, Nakashima M. Full-Scale Shaking Table Test of a Base-Isolated Medical Facility Subjected to Vertical Motions. Earthquake Engineering & Structural Dynamics. 2013;42:1931-1949. https://doi.org/10.1002/eqe.2305
- Khoshnudian F, Motamedi D. Seismic Response of Asymmetric Steel Isolated Structures Considering Vertical Component of Earthquakes. KSCE Journal of Civil Engineering, KSCE. 2013;17(6):1333-1347. https://doi.org/10.1007/s12205-013-0115-5
- Ryan KL, Kelly JM, Chopra AK. Nonlinear Model for Lead-Rubber Bearings Including Axial-Load Effects. Journal of Engineering Mechanics, ASCE. 2014;131(12):1270-1278.
- ASCE. Minimum Design Loads for Buildings and Other Structures. ASCE/SEI 7-10. c2010.
- Naeim F, Kelly JM. Design of Seismic Isolated Structures : From Theory to Practice. Wiley: Chichester, England. c1999.
- Takeuchi Y, Aikawa Y, Hirotani T, Nakayama T, Norimono T, Umeki Y, Shimizu H. Development of an Evaluation Method for Seismic Isolation systems (Parts) The Basic Characteristics Test of a Seismic Isolation system for Nuclear Power Plant. 13th World Conference on Seismic Isolation, Energy Dissipation and Active Vibration Control of Structures, Sendai, Japan. c2013.
- Japan Electric Association. Technical Guidelines on Seismic Base Isolated System for Structural Safety and Design of Nuclear Power Plants. JEAG 4614. c2000.
- Computers and Structures Inc. SAP2000 user's manual. Berkeley, California, USA. c1999.
Cited by
- Seismic Response Evaluation of Mid-Story Isolation System According to the Change of Characteristics of the Seismic Isolation Device vol.18, pp.1, 2018, https://doi.org/10.9712/KASS.2018.18.1.109