DOI QR코드

DOI QR Code

구강 내 스캐너를 사용하여 CAD/CAM으로 제작된 왁스 코핑의 적합도 평가

Evaluation of marginal and internal gap of wax coping fabricated by CAD/CAM system using intraoral scanner

  • 김동연 (고려대학교 대학원 보건과학과 치의기공전공) ;
  • 정일도 (고려대학교 대학원 보건과학과 치의기공전공) ;
  • 이재준 (고려대학교 대학원 보건과학과 치의기공전공) ;
  • 김지환 (고려대학교 대학원 보건과학과 치의기공전공) ;
  • 김명배 (대한 치과CAD/CAM기공 학회) ;
  • 김웅철 (고려대학교 대학원 보건과학과 치의기공전공)
  • Kim, Dong-Yeon (Department of Dental Laboratory Science & Engineering, College of Health Science, Korea University) ;
  • Jung, Il-Do (Department of Dental Laboratory Science & Engineering, College of Health Science, Korea University) ;
  • Lee, Jae-Jun (Department of Dental Laboratory Science & Engineering, College of Health Science, Korea University) ;
  • Kim, Ji-Hwan (Department of Dental Laboratory Science & Engineering, College of Health Science, Korea University) ;
  • Kim, Myung-Bae (Korea academy of CAD/CAM Dental technology) ;
  • Kim, Woong-Chul (Department of Dental Laboratory Science & Engineering, College of Health Science, Korea University)
  • 투고 : 2014.12.31
  • 심사 : 2015.03.27
  • 발행 : 2015.03.30

초록

Purpose: The aim of this study was to evaluate the marginal and internal gap of wax copings fabricated from extraoral scanning with intraoral scanning. Methods: Fifteen study models(abutment of teeth 16) were made by PMMA. STL files of thirty abutment were prepared by intraoral scanning with extraoral scanning. Wax copings of thirty fabricated using CAD/CAM system. Marginal and internal gap of wax copings of thirty were measured by silicone replica technique and digital microscope(${\times}140$). Date were analyzed by using independent samples t-test. Results: Mean (SD) of two group were measured $55.61(27.42){\mu}m$ for totally gap of ES group and $60.67(33.14){\mu}m$ for totally gap of IS group. But marginal and internal gap of two group were not differences statistically significant(p>0.05). Conclusion: Evaluation of marginal and internal gap of two group showed that no differences statistically significant and clinically acceptable results.

키워드

참고문헌

  1. Al-Bakri I, Hussey D, Al-Omari W. The dimensional accuracy of four impression techniques with the use of addition silicone impression materials. J Clin Dent. 18(2), 29-33, 2006.
  2. Birnbaum N, Aaronson HB, Stevens C, Cohen B. 3D digital scanners: a high-tech approach to more accurate dental impressions. Inside dent. 5(4), 2009.
  3. Brandestini M, Moermann WH. Method and apparatus for the three-dimensional registration and display of prepared teeth. Google Patents, 1989.
  4. Christensen GJ. The challenge to conventional impressions. J Am Dent Assoc (1939). 139(3), 347, 2008. https://doi.org/10.14219/jada.archive.2008.0165
  5. Christensen GJ. Will digital impressions eliminate the current problems with conventional impressions. J Am Dent Assoc. 139(6), 761-763, 2008. https://doi.org/10.14219/jada.archive.2008.0258
  6. Eames WB, Wallace SW, Suway NB, Rogers LB. Accuracy and dimensional stability of elastomeric impression materials. J Prosthet Dent. 42(2), 159-162, 1979. https://doi.org/10.1016/0022-3913(79)90166-5
  7. Ender A, Mehl A. Accuracy of complete-arch dental impressions, a new method of measuring trueness and precision. J Prosthet Dent. 109(2), 121-128, 2013. https://doi.org/10.1016/S0022-3913(13)60028-1
  8. e Silva JSA, Erdelt K, Edelhoff D, Araujo E, Stimmelmayr M, Vieira LCC, et al. Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques. Clin oral investing. 18(2), 515-523, 2014. https://doi.org/10.1007/s00784-013-0987-2
  9. Felton D, Kanoy B, Bayne Sa, Wirthman G. Effect of in vivo crown margin discrepancies on periodontal health. J Prosthet Dent. 65(3), 357-364, 1991. https://doi.org/10.1016/0022-3913(91)90225-L
  10. Flugge TV, Schlager S, Nelson K, Nahles S, Metzger MC. Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner. Am J Orthod Dentofacial Orthop. 144(3), 471-478, 2013. https://doi.org/10.1016/j.ajodo.2013.04.017
  11. Fransson B, Oilo G, Gjeitanger R: The fit of metalceramic crowns, a clinical study. Dent Mater. 1(1), 197-199, 1985. https://doi.org/10.1016/S0109-5641(85)80019-1
  12. Guth JF, Keul C, Stimmelmayr M, Beuer F, Edelhoff D. Accuracy of digital models obtained by direct and indirect data capturing. Clin oral investing. 17(4), 1201-1208, 2013. https://doi.org/10.1007/s00784-012-0795-0
  13. Kokubo Y, Tsumita M, Kano T, Sakurai S, Fukushima S. Clinical marginal and internal gaps of zirconia all-ceramic crowns. J Prosthodont Res. 55(1), 40-43, 2011. https://doi.org/10.1016/j.jpor.2010.09.001
  14. Logozzo S, Zanetti EM, Franceschini G, Kilpela A, Makynen A. Recent advances in dental optics-Part I: 3D intraoral scanners for restorative dentistry. Opt Lasers Eng. 54, 203-221, 2014. https://doi.org/10.1016/j.optlaseng.2013.07.017
  15. McLean JW, von Fraunhofer JA. The estimation of cement film thickness by an in vivo technique. Br Dent J, 131(3), 107-111, 1971. https://doi.org/10.1038/sj.bdj.4802708
  16. Meng Z, Yao H, Liang Y, Li Y, Lan S, Wang G, et al. Measurement of the refractive index of human teeth by optical coherence tomography. J Biomed Opt. 14(3), 034010-034010-034014, 2009. https://doi.org/10.1117/1.3130322
  17. Molin M, Karlsson S. The fit of gold inlays and three ceramic inlay systems: A clinical and in vitro study. Acta Odontologica. 51(4), 201-206, 1993. https://doi.org/10.3109/00016359309040568
  18. Ostlund L. Cavity design and mathematics: their effect on gaps at the margins of cast restorations. Oper Dent. 10(4), 122-137, 1984.
  19. Patzelt SB, Emmanouilidi A, Stampf S, Strub JR, Att W. Accuracy of full-arch scans using intraoral scanners. Clin oral investing. 1-8, 2013.
  20. Perakis N, Belser UC, Magne P. Final impressions:a review of material properties and description of a current technique. Int J periodontics Restorative Dent. 24(2), 109-118, 2004.
  21. Pradies G, Zarauz C, Valverde A, Ferreiroa A, Martinez-Rus F. Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions based on wavefront sampling technology. J dent. 43(2), 201-208, 2015 https://doi.org/10.1016/j.jdent.2014.12.007
  22. Schoenbaum TR. Decoding CAD/CAM and digital impression units. Dent Today. 29(2), 140, 142, 144-145, 2010.

피인용 문헌

  1. 지르코니아 블록과 CAM 종류에 따른 코핑의 변연적합도와 기계적 특성 비교 vol.39, pp.2, 2017, https://doi.org/10.14347/kadt.2017.39.2.75