철골 및 합성기둥 내화성능 확보를 위한 내화페인트 열적 물성치 규명과 소요두께 제안

Clarification of the Thermal Properties of Intumescent Paint and Suggestion of the Required Fire Protection Thickness for Steel and Composite columns

  • Kim, Sun-Hee (Department of Architectural Engineering, University of Seoul) ;
  • Ok, Chi Yeol (Korea Institute of Construction Technology) ;
  • Choi, Sung-Mo (Department of Architectural Engineering, University of Seoul)
  • 투고 : 2015.01.28
  • 심사 : 2015.03.03
  • 발행 : 2015.03.31

초록

Other countries(USA, Europe) have performed the fire resistance design of buildings by the alternative performance design methods, which are based on fire engineering theories. However, in Korea, the process on the alternative fire resistance performance design has only suggested without any applications for real steel structures. Therefore, In the case of steel structures stagnant research on refractory measures face difficulties in introducing fire resistance design. In this study, first of all, Intumescent paint was analyze the thermal properties(thermal conductivity, specific heat and density). In Sequence, using the section factor by H-standard section propose of section concrete filled steel tube and hollow. finally presents a reasonable thickness Intumescent paint takes time to target performance of the proposed cross-section steel tube.

키워드

참고문헌

  1. Andrew H. Buchanan, (2001), Structural design for fire safety, John Wiley & Sons
  2. Architectural Engineers, (2010), Building Construction Technology, Gimundang
  3. Building Evacuation, (2006), Rules on criteria such as structural fire protection construction standard specification.
  4. David Rush. (2013), Fire performance of unprotected and protected concrete filled steel hollow structural Sections, University of Edinburgh
  5. Fireproof structure recognition and management rulebook, (2012), Korea Institute of Construction Technology
  6. Rahmanian I, Wang Y. (2009), Thermal Conductivity of Gypsum at High Temperatures A Combined Experimental and Numerical Approach, ACTA Poly technical Vol. 49 No. 1
  7. Joel K , Sensitivity Study of a Simplified Assessment Method- characterization of Fire Protection Materials of Steel Elements, Fire Safety Science-Proceedings of the sixth international symposium, pp 915-926
  8. Farooqi J. K. and Sheikh M. A. (2005), Finite Element Modeling of Thermal Transport in Composite Unit Cell using ABAQUS/CAE, 2005 ABAQUS Users' Conference pp 1-15
  9. Ding J. and Wang Y. C. (2008), Realistic modelling of thermal and structural behaviour of unprotected concrete filled tubular columns in fire, Journal of Constructional Steel Research, Vol. 64 No. 10 pp 1086-1102 https://doi.org/10.1016/j.jcsr.2007.09.014
  10. Hwang J. W., Ha S. H., Lee Y. H., Kim W. J. and Kwak H. G. (2013), A Numerical Model to Evaluate Fire-Resistant Capacity of the Reinforced Concrete Members, Journal of the Korea Concrete Institute, Vol. 25, No. 5, pp. 497-508 https://doi.org/10.4334/JKCI.2013.25.5.497
  11. Rules on criteria such as the evacuation of the building structural fire protection, enforcement, 17/03/2012, Land, Transport and Maritime Enforcement Ordinance No. 433
  12. Ministry of Land, Transport and Maritime Affairs Notice No. 2012-625, recognition and management standards, recognition and management of refractory structure detailed operating instructions of the refractory structure.

피인용 문헌

  1. Study of the Standard Testing Specifications for a Non-loading Performance Evaluation of Coating Material-sprayed Circular Steel Structures vol.30, pp.3, 2016, https://doi.org/10.7731/KIFSE.2016.30.3.007
  2. An Experimental Study on the Evaluation of the Fire-Resistance Performance of a Spray-Applied Rectangular Steel Structure vol.17, pp.1, 2017, https://doi.org/10.9712/KASS.2017.17.1.041