참고문헌
- A. Kurs, A. Karalis, R. Moffatt, J. D. Joannopoulos, P. Fisher, and M. Soljacic, "Wireless power transfer via strongly coupled magnetic resonances," Science, vol. 317, no. 5834, pp. 83-86, 2007. https://doi.org/10.1126/science.1143254
- A. P. Sample, D. A. Meyer, and J. R. Smith, "Analysis, experimental results, and range adaptation of magnetically coupled resonators for wireless power transfer," IEEE Transactions on Industrial Electronics, vol. 58, no. 2, pp. 544-554, 2011. https://doi.org/10.1109/TIE.2010.2046002
- S. Cheon, Y. H. Kim, S. Y. Kang, M. L. Lee, J. M. Lee, and T. Zyung, "Circuit-model-based analysis of a wireless energy-transfer system via coupled magnetic resonances," IEEE Transactions on Industrial Electronics, vol. 58, no.7, pp. 2906-2914, 2011. https://doi.org/10.1109/TIE.2010.2072893
- I. Awai and T. Ishida, "Design of resonator-coupled wireless power transfer system by use of BPF theory," Journal of the Korean Institute of Electromagnetic Engineering and Science, vol. 10 no. 4, pp. 237-243, 2010. https://doi.org/10.5515/JKIEES.2010.10.4.237
- T. Nagaoka, S. Watanabe, K. Sakurai, E. Kunieda, S. Watanabe, M. Taki, and Y. Yamanaka, "Development of realistic high-resolution whole-body voxel models of Japanese adult males and females of average height and weight, and application of models to radio-frequency electromagnetic field dosimetry," Physics in Medicine and Biology, vol. 49, no. 1, pp. 1-15, 2004. https://doi.org/10.1088/0031-9155/49/1/001
- C. Gabriel and S. Gabriel, "Compilation of the dielectric properties of body tissues at RF and microwave frequencies," King's College London, UK, 1996.
- S. Park, K. Wake, and S. Watanabe, "Incident electric field effect and numerical dosimetry for a wireless power transfer system using magnetically coupled resonances," IEEE Transactions on Microwave Theory and Techniques, vol. 61, no. 9, pp. 3461-3469, 2013. https://doi.org/10.1109/TMTT.2013.2274053
- S. Park, E. Kim, K. Wake, and S. Watanabe, "Dosimetry for two modes of resonance-based wireless power transfer system," in Proceedings of International Symposium on Electromagnetic Compatibility (EMC'14), Tokyo, Japan, 2014, pp. 210-213.
- International Commission on Non-Ionizing Radiation Protection, "Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz)," 1998; http://www.icnirp.org/cms/upload/publications/ICNIRPemfgdl.pdf.
피인용 문헌
- Influence of fields and SAR evaluation for 13.56 MHz EV resonance-based wireless power charging systems vol.59, pp.4, 2017, https://doi.org/10.1002/mop.30433
- Index extraction for electromagnetic field evaluation of high power wireless charging system vol.12, pp.7, 2017, https://doi.org/10.1371/journal.pone.0180019
- Numerical Exposure Assessment Method for Low Frequency Range and Application to Wireless Power Transfer vol.11, pp.11, 2016, https://doi.org/10.1371/journal.pone.0166720
- An Effective Experimental Optimization Method for Wireless Power Transfer System Design Using Frequency Domain Measurement vol.17, pp.4, 2017, https://doi.org/10.26866/jees.2017.17.4.208
- Evaluation of Electromagnetic Exposure During 85 kHz Wireless Power Transfer for Electric Vehicles vol.54, pp.1, 2018, https://doi.org/10.1109/TMAG.2017.2748498