DOI QR코드

DOI QR Code

Shape-Estimation of Human Hand Using Polymer Flex Sensor and Study of Its Application to Control Robot Arm

폴리머 굽힘센서를 이용한 손의 형상 추정과 로봇 팔 제어 연구

  • 이진혁 (서울과학기술대학교 에너지환경대학원) ;
  • 김대현 (서울과학기술대학교 기계.자동차공학과)
  • Received : 2015.01.20
  • Accepted : 2015.02.13
  • Published : 2015.02.28

Abstract

Ultrasonic inspection robot systems have been widely researched and developed for the real-time monitoring of structures such as power plants. However, an inspection robot that is operated in a simple pattern has limitations in its application to various structures in a plant facility because of the diverse and complicated shapes of the inspection objects. Therefore, accurate control of the robot is required to inspect complicated objects with high-precision results. This paper presents the idea that the shape and movement information of an ultrasonic inspector's hand could be profitably utilized for the accurate control of robot. In this study, a polymer flex sensor was applied to monitor the shape of a human hand. This application was designed to intuitively control an ultrasonic inspection robot. The movement and shape of the hand were estimated by applying multiple sensors. Moreover, it was successfully shown that a test robot could be intuitively controlled based on the shape of a human hand estimated using polymer flex sensors.

초음파 로봇 검사시스템은 발전설비 등 상시감시가 요구되는 구조물의 감시를 위해 연구와 개발이 활발히 진행되고 있다. 그러나 이러한 설비의 구조물은 형상과 구조가 매우 다양하고 복잡하여 단순한 패턴으로 이동과 검사가 가능한 로봇으로는 상시감시에 한계를 가지게 된다. 복잡한 구조물의 정밀검사는 정교한 행동이 가능한 로봇 시스템이 필요하다. 로봇의 제어를 초음파검사 작업자의 손의 형상에 따라 직관적으로 움직이도록 한다면 보다 정밀한 검사 로봇의 개발이 가능할 것으로 판단된다. 폴리머 굽힘센서는 대변형의 측정이 가능하고 곡면에 적용성이 높아 최근 인체 형상 측정 및 재활보조 등 다양한 활용을 위한 연구가 활발히 진행되고 있다. 본 연구에서는 구조물의 상시감시를 위한 초음파검사 로봇이 작업자의 손동작에 따라 동작이 가능한 직관적 제어를 위해 폴리머 굽힘센서를 이용하여 사람 손의 형상 감시 연구를 수행하였다. 다수의 센서를 적용하여 손의 다양한 움직임을 추정하고 실험적 검증을 통해 사람 손의 형상에 따른 직관적 로봇의 제어가 가능함을 확인하였다.

Keywords

References

  1. R. Murayama, S. Makiyama, M. Kodama and Y. Taniguchi, "Development of an ultrasonic inspection robot using an electromagnetic acoustic transducer for a Lamb wave and an SH-plate wave," Ultrasonics, Vol. 42, pp. 825-829 (2004) https://doi.org/10.1016/j.ultras.2004.01.059
  2. J.-H. Lee, S.-J. Lim, I.-K. Park and D.-H. Kim, "Development of automated ultrasonic testing system for partial joint-weld of heat exchanger's header to tube in power plant," Journal of the Korean Society for Nondestructive Testing, Vol. 30, No. 4, pp. 367-372 (2010)
  3. J.-H. Lee, S. Han, J. Ahn, D.-H. Kim and H. Moon, "Two-module robotic pipe inspection system with EMATs," Smart Structures and Systems, Vol. 13, No. 6, pp. 1041-1063 (2014) https://doi.org/10.12989/sss.2014.13.6.1041
  4. G.-S. Kim, "Design of a Three-Axis Force Sensor for Wrist Bending-Exercise Rehabilitation Robot," Journal of Sensor Science and Technology, Vol. 22, No. 2, pp. 118-123 (2013) https://doi.org/10.5369/JSST.2013.22.2.118
  5. H.-Y. Kim, J.-H. Lee and D.-H. Kim, "Musclar condition monitoring system using fiber bragg grating sensors," Journal of the Korean Society for Nondestructive Testing, Vol. 34, No. 5, pp. 362-368 (2014) https://doi.org/10.7779/JKSNT.2014.34.5.362
  6. G. Orengo, L. Sbernini, N. D. Lorenzo, A. Lagati and G. Saggio, "Curvature characterization of flex sensors for human posture recognition," Universal Journal of Biomedical Engineering, Vol 1, No. 1, pp. 10-15 (2013)
  7. http://www.spectrasymbol.com/flex-sensor