References
- C. G. Han, "Concrete with Spalling Resistance," J. Korea Concr. Inst., 10 [6] 5-10 (1998). https://doi.org/10.22636/MKCI.1998.10.6.5
- Q. Zhang, G. Ye, and E. Koenders, "Investigation of the Structure of Heated Portland Cement Paste by using Various Techniques," Const. Build. Mater., 38 1040-50 (2013). https://doi.org/10.1016/j.conbuildmat.2012.09.071
- K. Y. Kim, T. S. Yun, and K. P. Park, "Evaluation of Pore Structures and Cracking in Cement Paste Exposed to Elevated Temperatures by X-ray Computed Tomography," Cem. Concr. Res., 50 34-40 (2013). https://doi.org/10.1016/j.cemconres.2013.03.020
- G. F. Peng and Z. S. Huang, "Change in Microstructure of Hardened Cement Paste Subjected to Elevated Temperatures," Const. Build. Mater., 22 593-99 (2008). https://doi.org/10.1016/j.conbuildmat.2006.11.002
-
Y. Aono, F. Matsushita, S. Shibata, and Y. Hama, "Nanostructural Changes of C-S-H in Hardened Cement Paste during Drying at
$50^{\circ}C$ ," J. Adv. Concr. Technol., 5 [3] 313-23 (2007). https://doi.org/10.3151/jact.5.313 -
P. Mounanga, A. Khelidja, A. Loukilib, and V. Baroghel- Bouny, "Predicting
$Ca(OH)_2$ Content and Chemical Shrinkage of Hydrating Cement Pastes Using Analytical Approach," Cem. Concr. Res., 34 255-65 (2004). https://doi.org/10.1016/j.cemconres.2003.07.006 - H. H. Seleem, A. M. Rashad, and T. Elsokary, "Effect of Elevated Temperature on Physico-mechanical Properties of Blended Cement Concrete," Constr. Build. Mater., 25 1009-17 (2011). https://doi.org/10.1016/j.conbuildmat.2010.06.078
- S. G. Yoo, "Improvement of Fire Resistance for Railroad Tunnel Concrete Structures," pp. 35-6, Ph. D. Thesis, Seoul National University of Science and Technology, Korea, 2011.
- A. Mendes, J. G. Sanjayan, W. P. Gates, and F. Collins, "The Influence of Water Absorption and Porosity on the Deterioration of Cement Paste and Concrete Exposed to Elevated Temperatures, as in a Fire Event," Cem. Concr. Compos., 34 1067-74 (2012). https://doi.org/10.1016/j.cemconcomp.2012.06.007
- H. Song and Y. S. Soh, "Variation of Pore Structure of High Strength Concrete Including Silica Fume Exposed to High Temperature," J. Korea Concr. Inst., 16 [5] 597-604 (2004). https://doi.org/10.4334/JKCI.2004.16.5.597
- Q. Zeng, K. Li, T. Fen-chong, and P. Dangla, "Pore Structure Characterization of Cement Pastes Blended with Highvolume Fly-ash," Cem. Concr. Res., 42 194-204 (2012). https://doi.org/10.1016/j.cemconres.2011.09.012
- L. Alarcon-Ruiza, G. Platretb, E. Massieub, and A. Ehrlacher, "The Use of Thermal Analysis in Assessing the Effect of Temperature on a Cement Paste," Cem. Concr. Res., 35 609-13 (2005). https://doi.org/10.1016/j.cemconres.2004.06.015
- H. M. Jennings, "Refinements to Colloid Model of C-S-H in Cement: CM-II," Cem. Concr. Res., 38 275-89 (2008). https://doi.org/10.1016/j.cemconres.2007.10.006
Cited by
- Fire resistance evaluation of fiber-reinforced cement composites using cellulose nanocrystals vol.8, pp.4, 2019, https://doi.org/10.12989/acc.2019.8.4.311