DOI QR코드

DOI QR Code

Development and Validation of Liquid Chromatography-Tandem Mass Spectrometry Method for Quantification of Plasma Metanephrines for Differential Diagnosis of Adrenal Incidentaloma

  • Lee, Sae-Mi (Department of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Lee, Mi-Na (Department of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Oh, Hyeon Ju (Department of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Cho, Yoon Young (Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Kim, Jae Hyeon (Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Woo, Hye In (Department of Laboratory Medicine, Samsung Changwon Hospital, Sungkyunkwan University School of Medicine) ;
  • Park, Hyung-Doo (Department of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Lee, Soo-Youn (Department of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine)
  • Received : 2014.10.06
  • Accepted : 2015.06.12
  • Published : 2015.09.01

Abstract

High-resolution imaging techniques have increased the detection rate of adrenal incidentaloma. We developed a method of liquid chromatography-tandem mass spectrometry (LC-MS/MS) for detection of plasma free metanephrine (MN) and normetanephrine (NMN) and evaluated its analytical performance and clinical efficacy in differential diagnosis of adrenal incidentaloma. After solid-phase extraction, chromatographic isolation of the analytes and internal standard was achieved by column elution in the LC-MS/MS system. The analytes were detected in multiple-reaction monitoring mode by using positive electrospray ionization: MN, transition m/z $180.1{\rightarrow}165.1$; NMN, m/z $166.1{\rightarrow}134.1$. This method was validated for linearity, precision, accuracy, lower limits of quantification and detection, extraction recovery, and the matrix effect. Plasma concentrations of MN and NMN of 14 patients with pheochromocytoma were compared with those of 17 healthy volunteers, 10 patients with essential hypertension, and 60 patients with adrenal adenoma. The assay's linear range was 0.04-50.0 and 0.08-100.0 nmol/L for MN and NMN, respectively. Assay imprecision was 1.86-7.50%. The accuracy ranged from -7.50% to 2.00%, and the mean recovery of MN and NMN was within the range 71.5-95.2%. Our LC-MS/MS method is rapid, accurate, and reliable and useful for differential diagnosis of adrenal incidentaloma.

Keywords

Acknowledgement

Supported by : Korea Health Industry Development Institute (KHIDI)

References

  1. Bravo EL. Evolving concepts in the pathophysiology, diagnosis, and treatment of pheochromocytoma. Endocr Rev 1994;15:356-68. https://doi.org/10.1210/edrv-15-3-356
  2. Plouin PF and Gimenez-Roqueplo AP. Pheochromocytomas and secreting paragangliomas. Orphanet J Rare Dis 2006;1:49. https://doi.org/10.1186/1750-1172-1-49
  3. Pacak K, Eisenhofer G, Ahlman H, Bornstein SR, Gimenez-Roqueplo AP, Grossman AB, et al. Pheochromocytoma: recommendations for clinical practice from the First International Symposium. October 2005. Nat Clin Pract Endocrinol Metab 2007;3:92-102. https://doi.org/10.1038/ncpendmet0396
  4. Eisenhofer G, Goldstein DS, Kopin IJ, Crout JR. Pheochromocytoma: rediscovery as a catecholamine-metabolizing tumor. Endocr Pathol 2003;14:193-212. https://doi.org/10.1007/s12022-003-0012-4
  5. Sawka AM, Jaeschke R, Singh RJ, Young WF Jr. A comparison of biochemical tests for pheochromocytoma: measurement of fractionated plasma metanephrines compared with the combination of 24-hour urinary metanephrines and catecholamines. J Clin Endocrinol Metab 2003;88:553-8. https://doi.org/10.1210/jc.2002-021251
  6. Peaston RT, Graham KS, Chambers E, van der Molen JC, Ball S. Performance of plasma free metanephrines measured by liquid chromatography-tandem mass spectrometry in the diagnosis of pheochromocytoma. Clin Chim Acta 2010;411:546-52. https://doi.org/10.1016/j.cca.2010.01.012
  7. Grossman A, Pacak K, Sawka A, Lenders JW, Harlander D, Peaston RT, et al. Biochemical diagnosis and localization of pheochromocytoma: can we reach a consensus? Ann N Y Acad Sci 2006;1073:332-47. https://doi.org/10.1196/annals.1353.038
  8. Singh RJ and Eisenhofer G. High-throughput, automated, and accurate biochemical screening for pheochromocytoma: are we there yet? Clin Chem 2007;53:1565-7. https://doi.org/10.1373/clinchem.2007.089128
  9. Sawka AM, Gafni A, Thabane L, Young WF Jr. The economic implications of three biochemical screening algorithms for pheochromocytoma. J Clin Endocrinol Metab 2004;89:2859-66. https://doi.org/10.1210/jc.2003-031127
  10. Eisenhofer G, Siegert G, Kotzerke J, Bornstein SR, Pacak K. Current progress and future challenges in the biochemical diagnosis and treatment of pheochromocytomas and paragangliomas. Horm Metab Res 2008;40:329-37. https://doi.org/10.1055/s-2008-1073156
  11. de Jong WH, Graham KS, van der Molen JC, Links TP, Morris MR, Ross HA, et al. Plasma free metanephrine measurement using automated online solid-phase extraction HPLC tandem mass spectrometry. Clin Chem 2007;53:1684-93. https://doi.org/10.1373/clinchem.2007.087114
  12. Lagerstedt SA, O’Kane DJ, Singh RJ. Measurement of plasma free metanephrine and normetanephrine by liquid chromatography-tandem mass spectrometry for diagnosis of pheochromocytoma. Clin Chem 2004;50:603-11. https://doi.org/10.1373/clinchem.2003.024703
  13. Trufelli H, Palma P, Famiglini G, Cappiello A. An overview of matrix effects in liquid chromatography-mass spectrometry. Mass Spectrom Rev 2011;30:491-509. https://doi.org/10.1002/mas.20298

Cited by

  1. A simple and robust liquid chromatography tandem mass spectrometry assay for determination of plasma free metanephrines and its application to routine clinical testing for diagnosis of pheochromocytom vol.33, pp.10, 2015, https://doi.org/10.1002/bmc.4622
  2. Quantitative Measurement of Plasma Free Metanephrines by a Simple and Cost-Effective Microextraction Packed Sorbent with Porous Graphitic Carbon and Liquid Chromatography-Tandem Mass Spectrometry vol.2021, pp.None, 2021, https://doi.org/10.1155/2021/8821276
  3. Urinary Free Metanephrines for Diagnosis of Pheochromocytoma and Paraganglioma vol.36, pp.3, 2015, https://doi.org/10.3803/enm.2020.925
  4. Review of the Use of Liquid Chromatography-Tandem Mass Spectrometry in Clinical Laboratories: Part I-Development vol.42, pp.2, 2015, https://doi.org/10.3343/alm.2022.42.2.121