DOI QR코드

DOI QR Code

Asymmetrical PWM for Harmonics Reduction and Power Factor Improvement in PWM AC Choppers Using Bee Colony Optimization

  • Received : 2014.05.01
  • Accepted : 2014.10.13
  • Published : 2015.01.20

Abstract

This paper presents the application of bee colony optimization (BCO) to obtain the optimal switching angles for single phase PWM AC choppers. The optimal switching angles are found in the region of 0-${\pi}$ based on the asymmetrical PWM technique. This PWM process results in improvements of the total harmonic distortion of the output voltage and in the input power factor. Simulation and experimental results are compared with the conventional PWM to verify the performance of the proposed PWM process.

Keywords

I. INTRODUCTION

AC choppers have been widely used in many applications such as lighting, heating and soft start motor controllers [1]. Generally, there are two methods for varying the AC output voltage from a fixed AC voltage source. The first method is the phase angle control. The AC output voltage average of this method is controlled by the firing angle of the power switches [2]. Because of its simple configuration and thyristor-based switches, this method has the advantages of simple control circuit and the ability to controlling a large amount of economical power. However, it faces a delay of the firing angle which results in a discontinuation of the power flow at both the input and output sides and significant harmonics in the load current. The second method is to employ pulse width modulation (PWM) to control the power switches. This process produces an input current that is nearly sinusoidal, which results in a low total harmonic distortion, THDii. As for the phase angle, this process depends on the phase angle of the output current. This means that the input power factor, PFi, depends on the load power factor, PFo. However, the input power factor of this method is still higher than that of the phase angle control method [1].

In general, the PWM AC choppers for high power applications have a switching frequency that is fixed and low. This means that the PWM signal can be modified to achieve a better PFi or total harmonic distortion of the output voltage, THDvo. Many techniques have been proposed to improve the PWM performance of high PFi.. The references and the carrier signals are modified [3]-[5].

Recently, artificial intelligent techniques have been used to find the optimal switching angles of PWM patterns. They have been obtained with the use of a genetic algorithm (GA) [7], [8], particle swarm optimization (PSO) [9], [10], artificial neural network (ANN) [11], genetic algorithm and artificial neural network [12], [13], particle swarm optimization and artificial neural network [14], etc. However, in these papers, the solution of the switching angle is obtained in the quarter cycle 0-π/2, which may lead to a suboptimal solution. The authors of [18] applied BCO to find the optimal switching angles in the region between 0-π/2 to improve the THDvo

This paper proposes an optimal switching strategy based on BCO for PWM AC choppers. In this approach, BCO is adopted to obtain the optimal switching angles of the PWM pattern by considering the region between 0-π. The proposed approach aims to minimize the harmonic distortion of the converter’s output voltage while satisfying the technical constraints of the switching angle sequences. The results of previous work will be compared to the method proposed in this paper. In addition, experiments with a 770W AC-AC converter are used to confirm the performance of the proposed switching pattern in terms of reducing the THDvo and improving the PFi .

This paper is organized as follows. Section II describes the background of PWM AC choppers and presents the BCO concept. Section III expresses the problem formulation of the optimal switching strategy. Section IV proposes the BCO algorithm to provide the optimal PWM switching patterns. Sections V and VI show the simulation and experimental results, respectively. And the last section is the conclusion of this paper.

 

II. DESCRIPTION AND CONTROL TECHNIQUES OF AC CHOPPERS

The power circuit of a single phase PWM AC chopper is shown in Fig. 1. Power switch S1 performs as the switching device controlled by the PWM pattern to regulate the power delivered to the load, and switch S2 is a free-wheeling device for stored energy transferring to the load when switch S1 is turned off.

Fig. 1.Single phase AC Choppers.

A. Symmetrical PWM AC Choppers

The conventional PWM is shown in Fig. 2(a). The duty cycle and the switching frequency are fixed. This PWM process is very simple and can eliminate low order harmonic contents [15]. However, the THDo is still high and the PFi is low, depending on the load power factor. In symmetrical pulse width modulation (SPWM), the PWM switching angles in the region 0-π/2 are symmetrical with those in the region π/2-π as shown in Fig. 2(b). These are obtained with various heuristic approaches including GA, PSO, ANN [7]-[14] and BCO [18] for the improvement of the THDo and the PFi. However, these techniques only meet the optimal PWM switching angles in the region 0-π/2. As a result, these approaches may lead to a suboptimal solution.

Fig. 2.Waveforms of output voltage, load current, input current and harmonic spectra of output voltage. (a) Conventional PWM. (b) SPWM Optimization technique. (c) APWM Optimization technique.

B. Asymmetrical PWM AC Choppers

Fig. 2(c) shows the waveforms of the asymmetrical pulse width modulation (APWM) method. In this process, the optimal PWM switching angles are obtained in the region 0-π.

For the basic idea of this method, the PWM AC chopper waveforms are analyzed in the Fourier domain producing non-linear transcendental equations that are solved by the Newton-Raphson method [6]. However, it is difficult to determine the initial value in addressing those equations. The BCO algorithm is a very simple and robust stochastic optimization algorithm when compared with previous algorithms. In [19], the BCO algorithm was applied to find optimal PWM switching angles based on the APWM. However, the objective of this technique is only to improve the PFi. Therefore, this paper focuses on an improvement of the THDvo and the PFi based on the BCO algorithm, using the APWM method.

C. The Circuit Equation of a PWM AC Choppers

In the ideal PWM AC chopper, the fixed input voltage is transformed by the AC-AC converter into variable output voltage vo , the vo and io can be expressed as:

The output voltage can be represented by the Fourier series as:

The fundamental coefficients, A1 and B1, are expressed as:

The harmonic coefficients, An and Bn, are expressed as:

The output voltage of (3) is rewritten as:

Where, and Ørn = tan-1( Bn / An )

Therefore, the output current is rewritten as:

Where, X = ωL and Øon = tan-1( nX / R ). It is assumed that Ion and Von are the rms values of nth harmonic content of the output current and voltage, respectively. Thus, the THD of the output current and voltage are defined as:

Where n = 3, 5, 7...

Therefore, the input power factor (PFi) can be expressed as:

 

III. PROBLEM FORMULATION

To find the optimal APWM switching pattern for reducing total harmonic distortions, the objective function to minimize the total harmonic distortions can be written as:

Subject to

Where, C1 is the fundamental coefficient of the output voltage, Vo,ref is the reference output voltage, α and β are the turn-on and turn-off switching angle, and α1 = 0. The new search pattern proposed in this paper has some features that reduce the total harmonic distortion and improve the input power factor.

 

IV. PROPOSED SOLUTION ALGORITHM

The BCO algorithm imitates the intelligent behaviors of the bee found in the nature. There are two types of bees namely; scout bees and worker bees. The scout bees search for sources of nectar and return to the hive. After that, they perform a waggle dance, which notifies the direction, distance from the hive and the quality of the nectar to the worker bees. The worker bees bring nectar to the hive, a large number of them can collect more nectar from good sources than from other sources [16], [17].

In this paper, the BCO algorithm has been used in finding the APWM switching patterns. The solution is shown in Fig. 3 and it is obtained as follows:

Fig. 3.Proposed BCO algorithm.

Where, M is the number of pulses per half cycle of the APWM waveform and i = 1 to M.

 

V. SIMULATION RESULTS

The designed PWM AC chopper is simulated by several software packages. The optimal PWM switching angles are obtained by the MATLAB program. While the designed PWM chopper is simulated by the Pspice program with the following system parameters: Vi = 220 Vrms, fi = 50 Hz, Ro = 240 Ω, L = 300 mH and M = 6 pulses, at a load power factor of 0.9308 lagging.

A. Optimal Switching Angle Solution

For the BCO algorithm, the required parameters are listed in Table I. The BCO parameters are selected from an empirical examination with a reasonable computational cost. This affects both the convergence characteristic and the computational efficiency. The turn-on switching angles (αn) are set at 0, 30, 60, 90, 120 and 150 degrees. The optimal turn-off switching angles (βn) at various output voltage levels are shown in Table II.

TABLE IPARAMETERS OF BCO ALGORITHM

TABLE IIα1 = 0, α2 = 30, α3 = 60, α4 = 90, α5 = 120, α6 = 150 degrees

The optimal turn-off switching angles at various output voltage levels are used in the control of the PWM AC chopper simulated by Pspice and they are shown in Table II. Fig. 4 shows the waveforms of the output voltage and load current, and the harmonic spectrum of the output voltage of (a) the conventional PWM technique, (b) the BCO SPWM technique [18] and (c) the proposed APWM technique. As can be seen in Fig. 4, the harmonics of the proposed APWM technique are distributed into low frequencies. This may be a concern in some applications. However, its THDvo and PFi are improved when compared with those of the other techniques, which is the objective of this research.

Fig. 4.Waveforms of the output voltage, load current and output voltage harmonic spectrum at output voltage 160 Vrms. (a) Conventional PWM technique. (b) BCO SPWM technique. (c) Proposed APWM technique.

B. Comparative Results

Table III shows the simulated results of various techniques: the conventional PWM, BCO SPWM [18] and the proposed APWM techniques at an output voltage of 160 Vrms. The results show that the performance of proposed APWM technique in terms of the THDii, THDio, THDvo and PFi is better than that of the other techniques. Fig. 5 shows simulated results at various output voltage levels. The THDio and THDvo of the proposed technique (Fig. 5(a) and 5(b)) are significant low when compared with the other techniques for all of the output voltage levels. The PFi results are shown in Fig. 5(c). They show that the PFi of the proposed APWM technique is higher than those of the other techniques.

TABLE IIIPERFORMANCE OF THE CONVENTIONAL PWM, BCO SPWM TECHNIQUE [18] AND PROPOSED APWM TECHNIQUE AT LOAD POWER FACTOR 0.9308 (Z = 240+J300Ω) AND VO = 160 VRMS.

Fig. 5.THDio, THDvo and PFi versus various output voltage at PFo = 0.9308. (a) Total harmonic distortion of output current. (b) Total harmonic distortion of output voltage. (c) Input power factor.

Table IV shows a performance comparison between the proposed APWM technique and the conventional PWM technique at Vi = 220 Vrms, fi = 50 Hz and a load power factor that is 0.8 lagging (Z=50.26+j120Ω). As shown in this table, the proposed APWM technique has a better performance than the conventional PWM technique at all of the output voltage levels, especially, in case of the PFi .

TABLE IVPERFORMANCE OF THE CONVENTIONAL PWM AND PROPOSED APWM TECHNIQUE AT LOAD POWER FACTOR 0.8 (Z=50.26+J120Ω)

 

VI. EXPERIMENTAL RESULTS

This section shows experimental results to confirm the performance of the proposed APWM technique. Fig. 6 shows the experimental prototype used in the laboratory. The system parameters are specified as follows: Vi = 220 Vrms, fi = 50 Hz, Ro = 50.26 Ω, L = 120 mH and M = 6 pulses at a load power factor that is 0.8 lagging. The PIC microprocessor is programmed to generate the APWM switching patterns for controlling the gate signals of the switching devices. The turn-on switching angles are set as follows: 0, 30, 60, 90, 120 and 150 degrees. The optimal turn-off switching angles are equal to 22.2779, 58.1004, 72.9212, 114.7289, 129.7994 and 153.674 degrees at an output voltage of 140 V.

Fig. 6.Experimental prototype.

Fig. 7 shows a comparison between the simulation and experimental waveforms of the input voltage/current and output voltage/current at an output voltage of 140 Vrms. It can be seen that the experimental results are consistent with the simulation results.

Fig. 7.Simulation and experimental results: current and voltage at Vo = 140 Vrms. (a)-(b) input side. (c)-(d) output side. (voltage, 100 V/div, current, 2 A/div, 4 ms/div).

Fig. 8 shows the simulation and experimental results of the harmonic spectra of the input current, output current and output voltage. The measurements of the THDii, THDio (Total harmonic distortion of the output current) and THDvo are 71.05% 14.24% and 74.24%, respectively.

Fig. 8.Simulation and experimental results of harmonic spectra of the current and voltage at Vo = 140 Vrms. (a)-(b) THDii . (c)-(d) THDio. (e)-(f) THDvo. (voltage, 50 V/div, current, 1 A/div, 500 ms/div).

Fig. 9 shows the waveforms of the experiment at Vo = 140 Vrms where the PFi is equal to 0.972. From these results, it can be seen that the proposed APWM technique is able to improve the PFi which higher than the load power factor (0.8).

Fig. 9.Waveforms of an experimental result at Vo = 140 Vrms. (voltage, 400 V/div, current, 2 A/div, 4 ms/div).

Fig. 10 shows the PFi, THDii, THDvo and THDio of the proposed technique at various output voltage levels. It can be seen that the simulation results are consistent with the experimental results.

Fig. 10.Comparison between simulation and experimental results of PFI,THDII, THDVO AND THDIO.

 

VII. CONCLUSIONS

This paper presents an application of BCO to obtain the optimal switching angles for single phase AC Chopper. In this technique, the switching angles are found in the region of 0-π of the sinusoidal waveform. From the simulation and experimental results, it can be seen that the performance of the proposed APWM technique is better than that the obtained by conventional PWM and SPWM techniques, especially, in the case of the output voltage-input current harmonic distortion and the input power factor. However, in the proposed technique, the harmonics still distribute at low frequencies. This problem should be considered in future work.

References

  1. M. H. Rashid, Power Electronics: Circuits, Devices and Applications, Upper Saddle River, NJ: Prentice-Hall, 1993.
  2. M. E. Balci and M. H. Hocaoglu, "Effects of source voltage harmonic distortion on power factor compensation in triac controlled AC chopper circuits," in Proc. IEEE PEDS, Vol. 2, pp. 1199-1204, 2005.
  3. G. H. Choe and D. H. Jang, "Asymmetrical PWM technique for AC choppers," in Proc. IEEE Conference on Industrial Electronics, Control and Instrumentation (IECON'91), pp. 587-592, 1991.
  4. D. H. Jang and G. H. Choem "Improvement of input power factor in AC choppers using asymmetrical PWM technique," IEEE Transactions on Industrial Electronics, Vol. 42, No. 2, pp. 179-185, Apr. 1995. https://doi.org/10.1109/41.370384
  5. G. H. Choe, A. K. Wallace, and M. H. Park. "An improved PWM technique for AC choppers," IEEE Tran. Power Electron., Vol. 4, No. 4, pp. 496-505, Oct. 1989. https://doi.org/10.1109/63.41778
  6. D. H. Jang, G. H. Choe, and M. Ehsani. "Asymmetrical PWM technique with harmonic elimination and power factor control in AC choppers," IEEE Trans. Power Electron., Vol. 10, No. 2, pp. 175-184, Mar. 1995. https://doi.org/10.1109/63.372602
  7. S. S. Rao and N. Shailaja, "Improving voltage regulation and harmonic elimination using genetic algorithm in PWM choppers," in Proc. IEEE Conference on International Telecommunication Energy (INTELEC'05), pp. 449-454, 2005.
  8. A. K. Al-Othman, N. A. Ahmed, A. M. Al-Kandari, and H. K. Ebraheem, "Selective harmonic elimination of PWM AC/AC voltage controller using hybrid RGA-PS approach," Journal of World Academy of Science, Engineering and Technology, Vol. 1, No. 5, pp.140-146, 2007.
  9. A. Kouzou, S. Saadi, M. O. Mahmoudi, and M. S. Boucherit, "Voltage quality enhancement of PWM AC Voltage controller using Particle Swarm Optimization," in Proc. the IEEE Conference on Power Engineering, Energy and Electrical Drives (POWERENG), pp. 309-314, 2009.
  10. S. M. Sadr, M. Monfared, and H. R. Mashhadi, "Application of PSO for selective harmonic elimination in a PWM AC/AC voltage regulator," in Proc. the 2nd International eConference on Computer and Knowledge Engineering (ICCKE), pp. 62-65, 2012.
  11. M. Z. Bilgin and U. Kilicarslan, "Voltage harmonic elimination of PWM AC chopper using artificial neural network," in Proc. IEEE ELECO'2010, pp. 173-178, 2010.
  12. S. Kaitwanidvilai and P. Piyarungsan. "Low-cost microprocessor-based alternating current voltage controller using genetic algorithms and neural network," IET Power Electron., Vol. 3, No. 4, pp. 490-499, Jul. 2010. https://doi.org/10.1049/iet-pel.2009.0035
  13. P. Jitta, S. Kaitwanidvilai, and A. Ngaopitakkul, "Switching angle design for pulse width modulation AC voltage controller using genetic algorithm and distributed artificial neural network," in Proc. the International MultiConference of Engineers and Computer Scientists, Vol. 2, 2011.
  14. P. piyarungsan and S. kaitwanidvilai. "Harmonic reduction technique in PWM AC voltage controller using particle swarm optimization and artificial neural network," in Proc. IMECS, Vol. 2, 2010.
  15. R.Arun Sagar and B.Vasanth Reddy. "Comparative analysis of SPWM and APWM Techniques for Three Phase AC Chopper," The International journal of Emerging trends in Engineering and Development, Issue 2, Vol.4, pp.230-237, 2012.
  16. D. T. Pham, A. Ghanbarzadeh, E. Koc, S. Otri, S. Rahim, and M. Zaidi, "The Bees Algorithm-Technical Note," Manufacturing Engineering Centre, Cardiff University, UK, 2005.
  17. D. T. Pham, A. Ghanbarzadeh, E. Koc, S. Otri, S. Rahim, and M. Zaidi, "The bees algorithm-A novel tool for complex optimisation problems," in Proc. IPROMS 2006 Conference, pp. 454-461, 2006.
  18. W. Khamsen and A. Aurasopon, and C. Boonchuay "Optimal switching pattern for PWM AC-AC converter using bee colony optimization," Journal of Power Electronics, Vol. 14, No. 2, pp. 362-368, Mar. 2014. https://doi.org/10.6113/JPE.2014.14.2.362
  19. W. Khamsen, A. Aurasopon, and W. Sa-ngiamvibool, "Power factor improvement and voltage harmonics reduction in pulse width modulation AC chopper using bee colony optimization," IETE Technical Review, Vol. 30, No. 3, pp. 173-182, May/Jun. 2013. https://doi.org/10.4103/0256-4602.113478

Cited by

  1. Optimal harmonic reduction approach for PWM AC–AC converter using nested memetic algorithm vol.21, pp.10, 2017, https://doi.org/10.1007/s00500-015-1979-8
  2. Voltage Source Inverter Drive Using Error-compensated Pulse Width Modulation vol.16, pp.1, 2016, https://doi.org/10.6113/JPE.2016.16.1.388