DOI QR코드

DOI QR Code

Reconstruction of In-beam PET for Carbon therapy with prior-knowledge of carbon beam-track

  • Kim, Kwangdon (Department of IT Convergence, Korea University) ;
  • Bae, Seungbin (Department of Bio-convergence Engineering, Korea University) ;
  • Lee, Kisung (Department of Bio-convergence Engineering, Korea University) ;
  • Chung, Yonghyun (Department of Radiological Science, Yonsei University) ;
  • An, Sujung (Department of Radiological Science, Yonsei University) ;
  • Joung, Jinhun (Department of Bio-convergence Engineering, Korea University)
  • Received : 2015.10.15
  • Accepted : 2015.11.30
  • Published : 2015.12.31

Abstract

There are two main artifacts in reconstructed images from in-beam positron emission tomography (PET). Unlike generic PET, in-beam PET uses the annihilation photons that occur during heavy ion therapy. Therefore, the geometry of in-beam PET is not a full ring, but a partial ring that has one or two openings around the rings in order for the hadrons to arrive at the tumor without prevention of detector blocks. This causes truncation in the projection data due to an absence of detector modules in the openings. The other is a ring artifact caused by the gaps between detector modules also found in generic PET. To sum up, in-beam PET has two kinds of gap: openings for hadrons, and gaps between the modules. We acquired three types of simulation results from a PET system: full-ring, C-ring and dual head. In this study, we aim to compensate for the artifacts that come from the two types of gap. In the case of truncation, we propose a method that uses prior knowledge of the location where annihilations occur, and we applied the discrete-cosine transform (DCT) gap-filling method proposed by Tuna et al. for inter-detector gap.

Keywords

References

  1. Y. Shao et al., "Development of a PET Detector System Compatible with MRI/NMR Systems", IEEE Trans. Nucl. Sci., Vol. 44, No. 3, pp. 1167-1171, 1997. https://doi.org/10.1109/23.596982
  2. Rigo, Pierre, et al. "Oncological applications of positron emission tomography with fluorine-18 fluorodeoxyglucose." European journal of nuclear medicine, Vol. 23, No. 12, pp. 1641-1674. 1996. https://doi.org/10.1007/BF01249629
  3. Weber, Wolfgang A., et al. "Positron emission tomography in non-small-cell lung cancer: prediction of response to chemotherapy by quantitative assessment of glucose use." Journal of Clinical Oncology, Vol. 21, No. 14, pp. 2651-2657, 2003. https://doi.org/10.1200/JCO.2003.12.004
  4. Van den Abbeele et al., "Use of positron emission tomography in oncology and its potential role to assess response to imatinib mesylate therapy in gastrointestinal stromal tumors (GISTs)", European Journal of Cancer, Vol. 38, S60-S65, 2002.
  5. Ugo Amaldi and Gerhard Kraft, "Radiotherapy with beams of carbon ions", Rep. Prog. Phys., Vol. 68, pp. 1861-1882, 11 July 2005. https://doi.org/10.1088/0034-4885/68/8/R04
  6. F. Attanasi et al., "Preliminary results of an in-beam PET prototype for proton therapy", Nuclear Instruments and Methods in Physics Research A, Vol. 591, pp. 296-299, 2008. https://doi.org/10.1016/j.nima.2008.03.076
  7. C. Paulo et al., "On the detector arrangement for inbeam PET for hadron therapy monitoring", Phys. Med. Biol., Vol. 51, No. 9, pp. 2143-2163, 2006. https://doi.org/10.1088/0031-9155/51/9/002
  8. S. Vecchio et al., "A PET Prototype for "In-Beam" Monitoring of Proton Therapy", IEEE Trans. Nucl. Sci., Vol. 56, No. 1, pp. 51-56, 2009. https://doi.org/10.1109/TNS.2008.2008306
  9. De Jong, Hugo WAM, et al. "Correction methods for missing data in sinograms of the HRRT PET scanner." IEEE Trans. Nucl. Sci., Vol. 50. No. 5, pp. 1452-1456, 2003. https://doi.org/10.1109/TNS.2003.817366
  10. J. S. Karp et al., "Constrained Fourier space method for compensation of missing data in emission computed tomography," IEEE Trans. Med. Imag., Vol. 7, No. 1, pp. 21-25, Mar. 1988.
  11. Uygar Tuna et al., "Gap-Filling for the High-Resolution PET Sinograms With a Dedicated DCT-Domain Filter", IEEE Transactions On Medical Imaging, Vol. 29, No. 3, March 2010.
  12. Damian Borys et al., "System matrix computation for iterative reconstruction algorithms in Spect based on direct measurements", Int. J. Appl. Math. Comput. Sci., Vol. 21, No. 1, pp. 193-202, 2011. https://doi.org/10.2478/v10006-011-0014-1
  13. Herfried Wieczorek, "The image quality of FBP and MLEM reconstruction", Phys. Med. Biol., Vol. 55, p. 3161 2010 https://doi.org/10.1088/0031-9155/55/11/012