References
- Y. Shao et al., "Development of a PET Detector System Compatible with MRI/NMR Systems", IEEE Trans. Nucl. Sci., Vol. 44, No. 3, pp. 1167-1171, 1997. https://doi.org/10.1109/23.596982
- Rigo, Pierre, et al. "Oncological applications of positron emission tomography with fluorine-18 fluorodeoxyglucose." European journal of nuclear medicine, Vol. 23, No. 12, pp. 1641-1674. 1996. https://doi.org/10.1007/BF01249629
- Weber, Wolfgang A., et al. "Positron emission tomography in non-small-cell lung cancer: prediction of response to chemotherapy by quantitative assessment of glucose use." Journal of Clinical Oncology, Vol. 21, No. 14, pp. 2651-2657, 2003. https://doi.org/10.1200/JCO.2003.12.004
- Van den Abbeele et al., "Use of positron emission tomography in oncology and its potential role to assess response to imatinib mesylate therapy in gastrointestinal stromal tumors (GISTs)", European Journal of Cancer, Vol. 38, S60-S65, 2002.
- Ugo Amaldi and Gerhard Kraft, "Radiotherapy with beams of carbon ions", Rep. Prog. Phys., Vol. 68, pp. 1861-1882, 11 July 2005. https://doi.org/10.1088/0034-4885/68/8/R04
- F. Attanasi et al., "Preliminary results of an in-beam PET prototype for proton therapy", Nuclear Instruments and Methods in Physics Research A, Vol. 591, pp. 296-299, 2008. https://doi.org/10.1016/j.nima.2008.03.076
- C. Paulo et al., "On the detector arrangement for inbeam PET for hadron therapy monitoring", Phys. Med. Biol., Vol. 51, No. 9, pp. 2143-2163, 2006. https://doi.org/10.1088/0031-9155/51/9/002
- S. Vecchio et al., "A PET Prototype for "In-Beam" Monitoring of Proton Therapy", IEEE Trans. Nucl. Sci., Vol. 56, No. 1, pp. 51-56, 2009. https://doi.org/10.1109/TNS.2008.2008306
- De Jong, Hugo WAM, et al. "Correction methods for missing data in sinograms of the HRRT PET scanner." IEEE Trans. Nucl. Sci., Vol. 50. No. 5, pp. 1452-1456, 2003. https://doi.org/10.1109/TNS.2003.817366
- J. S. Karp et al., "Constrained Fourier space method for compensation of missing data in emission computed tomography," IEEE Trans. Med. Imag., Vol. 7, No. 1, pp. 21-25, Mar. 1988.
- Uygar Tuna et al., "Gap-Filling for the High-Resolution PET Sinograms With a Dedicated DCT-Domain Filter", IEEE Transactions On Medical Imaging, Vol. 29, No. 3, March 2010.
- Damian Borys et al., "System matrix computation for iterative reconstruction algorithms in Spect based on direct measurements", Int. J. Appl. Math. Comput. Sci., Vol. 21, No. 1, pp. 193-202, 2011. https://doi.org/10.2478/v10006-011-0014-1
- Herfried Wieczorek, "The image quality of FBP and MLEM reconstruction", Phys. Med. Biol., Vol. 55, p. 3161 2010 https://doi.org/10.1088/0031-9155/55/11/012