The Change of the Near Eye Position according to the Spectacle and Contact Lens Wearing

안경과 콘택트렌즈 착용에 따른 근거리안위의 변화

  • Han, Sun-Hee (Department of Optometry, Choonhae College of Health Sciences) ;
  • Kim, Bong-Hwan (Department of Optometry, Choonhae College of Health Sciences) ;
  • Kim, Hak-Jun (Department of Optometry, Choonhae College of Health Sciences) ;
  • Park, Jun-Sung (Department of Optometry, Choonhae College of Health Sciences) ;
  • Park, Hae-Been (Department of Optometry, Choonhae College of Health Sciences) ;
  • Kim, Mi-Jeong (Department of Optometry, Choonhae College of Health Sciences) ;
  • Park, Ju-Hyeong (Department of Optometry, Choonhae College of Health Sciences) ;
  • Kim, Jin-Sol (Department of Optometry, Choonhae College of Health Sciences) ;
  • Lee, Kyeong-Hoon (Department of Optometry, Choonhae College of Health Sciences) ;
  • Kim, Jong-Hwan (Department of Optometry, Choonhae College of Health Sciences) ;
  • Ha, Na-Ri (Department of Optometry, Choonhae College of Health Sciences)
  • 한선희 (춘해보건대학교 안경광학과) ;
  • 김봉환 (춘해보건대학교 안경광학과) ;
  • 김학준 (춘해보건대학교 안경광학과) ;
  • 박준성 (춘해보건대학교 안경광학과) ;
  • 박혜빈 (춘해보건대학교 안경광학과) ;
  • 김미정 (춘해보건대학교 안경광학과) ;
  • 박주형 (춘해보건대학교 안경광학과) ;
  • 김진솔 (춘해보건대학교 안경광학과) ;
  • 이경훈 (춘해보건대학교 안경광학과) ;
  • 김종환 (춘해보건대학교 안경광학과) ;
  • 하나리 (춘해보건대학교 안경광학과)
  • Received : 2015.09.20
  • Accepted : 2015.10.01
  • Published : 2015.12.31

Abstract

Purpose. This study was to investigate comparison of the near eye position according to the spectacle and contact lens wearing. Methods. We measured the AC/A ratio and near horizontal phoria using modified Thorington method in each case spectacle and contact lens wearing of equivalent spherical power after measuring the full corrected diopter for 20 subjects (men 5, woman 15, $21.15{\pm}1.35$ years) without specific ocular diseases, ocular surgery experience and vision anomalies. Results. It was shown high correlation between spectacle and contact lens wearing as AC/A ratio is a correlation coefficient 0.99 (p=0.00), near horizontal phoria is a correlation coefficient 0.95 (p=0.00). And contact lens wearing increased as AC/A ratio by $0.32{\pm}1.35$ ${\Delta}/D$ (p=0.31) and near horizontal phoria by $-0.17{\pm}2.18$ ${\Delta}$ (p=0.73) than spectacle wearing but there was no statistically significant difference. As the higher myopic grade AC/A ratio increased and then was shown decreased tendency in -6.00 D < $SED{\leq}-4.00$ D group (p>0.05) and as the higher myopic grade near exophoria increased but there was no statistically significant difference (p>0.05). Conclusions. We should consider that the subjects who had the lower AC/A ratio or higher near exophoria in -6.00 D < $SED{\leq}-4.00$ D group were necessary to measure AC/A ratio and near horizontal phoria when they were wearing contact lens because contact lens wearing tended to increase the near exophoria than spectacle wearing.

Keywords

References

  1. Gallup korea, Korean optometric association: The 2015's report on rate of spectacle and contact lens use all over the country, 2015. http://www.optic.or.kr/Cate_05/content.asp?ref=40&step=1&re_level=1&board_id=cate04_1&page=2&board_kind_sub=. Accessed Octobal 29 2015.
  2. Lee KB, Park JH, Kim HJ. Comparison of accommodative response among emmetropes, spectacle and contact lens wearer. J Korean Oph Opt Soc, 2012;17(4):403-410.
  3. Sung PJ. Optometry. Daihakserim, 8th Ed. 2014.
  4. Mah KC, Lee GJ. Contact lens. Daihakserim, 1st Ed. 1995.
  5. Park SC, Shin JC, Shin HS. Reliability of the amplitude of accommodation measurements between spectacle and contact lens wearers. Kor J Vis Sci, 2006;8(2):21-28.
  6. Jimenez R, Martinez-Almeida L, Salas C, et al. Contact lenses vs spectacles in myopes: is there any difference in accommodative and binocular function?. Graefes Arch Clin Exp Ophthalmol, 2011;249(6):925-935. https://doi.org/10.1007/s00417-010-1570-z
  7. Shim HS, Kim SH, Kim YC. Correlation of near stereoacuity and phoria, and refractive error. J Korean Oph Opt Soc, 2015;20(1):67-73. https://doi.org/10.14479/jkoos.2015.20.1.67
  8. Kim JH, Kim CS. The factors influencing the asthenopia of myopia with phoria. J Korean Oph Opt Soc, 2005;10(4):419-428.
  9. Hong DG, Jung HS, Park SA. Analysis of far & near distance of lateral phoria by various testing methods. J Korean Oph Opt Soc, 2004;9(2):423-430.
  10. Doo HY, Sim SH, Choi SM et al. A study on the long distance heterophoria of college students by the difference of testing method. Kor J Vis Sci, 2011;13(1):43-49.
  11. Lee KB, Jeon SW, Lee HJ et al. The comparative analysis of various distance phoria tests. Kor J Vis Sci, 2007;9(1):115-125.
  12. Kim JH. The factors influencing the quantity of phoria. J Korean Oph Opt Soc, 2004;9(2):361-370.
  13. Lee KJ. Contact lens practice, Hanmaek book, 2st Ed. Kyeonggido, 2013.
  14. Kim JD, Kim HJ, Hwang JH. Relation between gradient and calculated AC/A ratios according to binocular vision types. Kor J Vis Sci, 2012;14(4):373-380.
  15. Kim HK, Lee KB, Kim CJ et al. Comparison of accommodative responses and response AC/A ratio in emmetropic and myopic children. Kor J Vis Sci, 2012;14(4):353-362.
  16. Kang IS, Seo YW, Choi JY. The analysis of binocular vision function by measuring accommodative convergence(AC/A). J Korean Oph Opt Soc, 2005;10(3):159-164.
  17. Jeon IC, Mah KC, Jang MH et al. Comparison of repeatability of heterophoria measurement techniques by gradient AC/A ratio. Kor J Vis Sci, 2008;10(2):147-155.
  18. Park SJ, Kwak HB, Lee SH et al. A study and analysis of accommodative convergence/accommodation ratio by measuring methods. J Korean Oph Opt Soc. 2013;18(2):117-123. https://doi.org/10.14479/jkoos.2013.18.2.117
  19. Lee SH, Yu DS, Son JS et al. Comparison between stimulus and response AC/A ratios for each phoria with additional spherical power. J Korean Oph Opt Soc, 2014;19(3):345-351. https://doi.org/10.14479/jkoos.2014.19.3.345
  20. Rainey BB, Schroeder TL, Goss DA et al. Inter-examiner repeatability of heterophoria test. Optom Vis Sci, 1998;75(10):719-726. https://doi.org/10.1097/00006324-199810000-00016
  21. Schroeder TL, Rainey BB, Goss DA et al. Reliability of and comparisons among methods of measuring dissociated phoria. Optom Vis Sci, 1996;73(6):389-397. https://doi.org/10.1097/00006324-199606000-00006