DOI QR코드

DOI QR Code

Inferior Blow-Out Fracture Reduction Using Two Urinary Balloon Catheters

  • Jo, Eun Jun (Department of Plastic and Reconstructive Surgery, Eulji University College of Medicine) ;
  • Kim, Jong Hwan (Department of Plastic and Reconstructive Surgery, Eulji University College of Medicine) ;
  • Yang, Ho Jik (Department of Plastic and Reconstructive Surgery, Eulji University College of Medicine)
  • 투고 : 2015.03.06
  • 심사 : 2015.03.30
  • 발행 : 2015.12.09

초록

Background: The reduction of orbital blowout fracture primarily aims to normalize the extra-ocular movement by returning the herniated orbital soft tissue into the original position, and to prevent enophthalmos by normalizing the orbital cavity volume. We introduce a balloon catheter-assisted orbital floor reduction technique. Methods: A retrospective review was performed for all patients with orbital floor fracture who underwent the technique described in the main body of this text. Medical records were reviewed for demographic data, clinical presentation and course, degree of enophthalmos, intraorbital volume on computed tomography scan, and postoperative outcomes. The enophthalmos and intraorbital volume of the injured site were compared to the uninjured eye and orbit. Results: The review identified 14 patients (11 male, 3 female). The mean preoperative difference in en-exopthalmos was 2.13 mm, while the mean orbital volume was 116%. The mean postoperative difference in en-exophthalmos had improved to 0.61 mm with a mean orbital volume of 101.85%. At the time of catheter removal at 10 days, three patients experienced diplopia (n=1), extra-ocular movement disorder (1), or enophthalmos (1). All of these had resolved by the 6-month follow-up visit. Conclusion: Balloon catheter-assisted reduction of the orbital floor fractures was associated with improvements in intraorbital volume and enopthalmos in the 14 patients. Notable complications included diplopia, enophthalmos, and limited extra-ocular movement, all of which were transient in the early postoperative period and had resolved by 6-month follow up.

키워드

참고문헌

  1. Saunders CJ, Whetzel TP, Stokes RB, Wong GB, Stevenson TR. Transantral endoscopic orbital floor exploration: a cadaver and clinical study. Plast Reconstr Surg 1997;100:575-81. https://doi.org/10.1097/00006534-199709000-00003
  2. Joo K, Chung SH, Han KT, Kwon H, Im JS, Kang YJ. A comparative study of the implants used in the management of blowout fracture. J Korean Soc Plast Reconstr Surg 1999;26:470-6.
  3. Choi HJ, Kim MS, Lee YM. The endoscopic treatment of blow-out fracture. J Korean Cleft Palate-Craniofac Assoc 2002;3:173-8.
  4. Hwang WB, Bae YC, Jeon JY, Hwang SM, Lee J, Kim DH. Orbital volume change in post-traumatic enophthalmos. J Korean Soc Plast Reconstr Surg 1997;24:1031-43.
  5. Whitehouse RW, Batterbury M, Jackson A, Noble JL. Prediction of enophthalmos by computed tomography after 'blow out' orbital fracture. Br J Ophthalmol 1994;78:618-20. https://doi.org/10.1136/bjo.78.8.618
  6. Raskin EM, Millman AL, Lubkin V, della Rocca RC, Lisman RD, Maher EA. Prediction of late enophthalmos by volumetric analysis of orbital fractures. Ophthal Plast Reconstr Surg 1998;14:19-26. https://doi.org/10.1097/00002341-199801000-00006
  7. McGurk M, Whitehouse RW, Taylor PM, Swinson B. Orbital volume measured by a low-dose CT scanning technique. Dentomaxillofac Radiol 1992;21:70-2. https://doi.org/10.1259/dmfr.21.2.1397459
  8. Grant MP, Iliff NT, Manson PN. Strategies for the treatment of enophthalmos. Clin Plast Surg 1997;24:539-50.
  9. Kim YH, Seul JH. An analysis of delayed correction of 25-cases of post traumatic ocular displacement. J Korean Soc Plast Reconstr Surg 1997;24:1016-30.
  10. Johnson PE, Raftopoulos I. In situ splitting of a rib graft for reconstruction of the orbital floor. Plast Reconstr Surg 1999;103:1709-11. https://doi.org/10.1097/00006534-199905000-00023
  11. Kline RM Jr, Wolfe SA. Complications associated with the harvesting of cranial bone grafts. Plast Reconstr Surg 1995;95:5-13. https://doi.org/10.1097/00006534-199501000-00002
  12. Jobe R, Iverson R, Vistnes L. Bone deformation beneath alloplastic implants. Plast Reconstr Surg 1973;51:169-75. https://doi.org/10.1097/00006534-197302000-00012
  13. Musch DC, Frueh BR, Landis JR. The reliability of Hertel exophthalmometry: observer variation between physician and lay readers. Ophthalmology 1985;92:1177-80. https://doi.org/10.1016/S0161-6420(85)33880-0