DOI QR코드

DOI QR Code

An Analysis of Design Formulas on Section Types of Rectangular Concrete Filled Steel Tube Columns

각형 콘크리트 충전강관기둥의 단면형태별 축압축강도 설계식 분석

  • 홍건호 (호서대학교 건축공학과) ;
  • 최인락 (포스코(포항산업과학연구원)) ;
  • 정경수 (포스코(포항산업과학연구원))
  • Received : 2014.09.03
  • Accepted : 2014.10.30
  • Published : 2014.11.30

Abstract

The purpose of this study is to analyze the axial load capacity equations for rectangular CFT columns in the AISC 360-10 (the US design code for structural steel buildings) which is being investigated as a revision of Korean Building Code. Main parameters were the width-to-thickness ratios of composite member and material strength as 30~100MPa of concrete compressive strength and 325~725MPa of yield strength of structural steel. The first method of changing width-to-thickness ratios was to fix the thickness of structural steel to 5mm and to increase the size of member. The second method was to fix the size of member to $620mm{\times}620mm$ and to change the thickness of structural steel. The analysis results indicated that axial load capacity used higher strength steel is lower than the capacity used lower strength one in some regions although the section size was equal. The reason of this result is due to the different section type that is classified by the equation of limit width-to-thickness ratios. When the yield strength of structural steel become higher, its section type and axial load capacity equation is changed though its width-to-thickness ratio is the same with the lower yield strength members. The region of this phenomenon is become wider following to the increase of concrete compressive strength because part of concrete load capacity is govern the total load capacity of members. To resolve this irregular phenomenon that axial load capacity is reversed in some region, it is necessary to modify the code provision for calculation the load capacity in high strength materials.

Keywords

Acknowledgement

Supported by : 국토교통부

References

  1. 이성욱, 엄철환, 김동규, "콘크리트 충진 각형강관의 국부좌굴 보강효과 및 폭두께비 제한에 관한 실험적 연구", 대한건축학회 학술발표논문집 Vol.6, No.1, 1986, p.p.389-392
  2. 정헌모 외 4인, "이중간관 CFT 단주의 구조성능 평가", 대한건축학회 학술발표논문집 구조계, Vol.29, No.1, 2009, p.p.405-408
  3. 이승조, 박정민, 김화중, "중심압축을 받는 고강도콘크리트 충전 각형강관 기둥의 내력특성", 대한건축학회논문집 구조계, Vol.18, No.7, 2002, p.p.11-18
  4. 박정민, 김화중, "콘크리트 충전 강관 단주의 축압축 거동 특성에 관한 실험적 연구", 대한건축학회논문집, Vol.11, No.6, 1995, p.p.125-135
  5. 문태섭 외 4인, "충전 콘크리트 원형강관주의 좌굴내력에 관한 실험적 연구", 대한건축학회 학술발표 논문집, Vol. 13, No.2, 1993, p.p.543-548
  6. 홍건호, 김원기, 최인락, 정경수, "고강도 원형 CFT의 판폭두께비 제한에 관한 실험적연구", 대한건축학회 논문집, Vol.29, No. 2, 2013, p.p.13-20
  7. 홍건호, 김원기, 조원대, 최인락, 정경수, 합성단면 분류 기준 에 따른 CFT 축 압축강도 설계식 평가", 한국콘크리트학회 학술발표 논문집, Vol.25, No.2, 2013, p.p.13-14
  8. AISC360-10 "Specification for Structural Steel Buildings", American Institute of Steel Construction, AISC, 2010, p.p.81-104