DOI QR코드

DOI QR Code

Tissue Responses to Stent Grafts with Endo-Exo-Skeleton for Saccular Abdominal Aortic Aneurysms in a Canine Model

  • Kim, Young Il (Department of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, Clinical Research Institute) ;
  • Choi, Young Ho (Department of Radiology, Seoul National University Boramae Hospital) ;
  • Chung, Jin Wook (Department of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, Clinical Research Institute) ;
  • Kim, Hyo-Cheol (Department of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, Clinical Research Institute) ;
  • So, Young Ho (Department of Radiology, Seoul National University Boramae Hospital) ;
  • Kim, Hyun Beom (Department of Radiology, National Cancer Center) ;
  • Min, Seung-Kee (Department of Surgery, Seoul National University College of Medicine) ;
  • Park, Jae Hyung (Department of Radiology, Gachon University Gil Medical Center)
  • Received : 2014.04.07
  • Accepted : 2014.07.06
  • Published : 2014.09.01

Abstract

Objective: We evaluated the effect of close contact between the stent and the graft on the induction of endothelial covering on the stent graft placed over an aneurysm. Materials and Methods: Saccular abdominal aortic aneurysms were made with Dacron patch in eight dogs. The stent graft consisted of an inner stent, a expanded polytetrafluoroethylene graft, and an outer stent. After sacrificing the animals, the aortas with an embedded stent graft were excised. The aortas were inspected grossly and evaluated microscopically. Results: The animals were sacrificed at two (n = 3), six (n = 3), and eight months (n = 2) after endovascular repair. In two dogs, the aortic lumen was occluded at two months after the placement. On gross inspection of specimens from the other six dogs with a patent aortic lumen, stent grafts placed over the normal aortic wall were covered by glossy white neointima, whereas, stent grafts placed over the aneurysmal aortic wall were covered by brownish neointima. On microscopic inspection, stent grafts placed over the normal aortic wall were covered by thin neointima ($0.27{\pm}0.05mm$, mean ${\times}$ standard deviation) with an endothelial layer, and stent grafts placed over the aneurysmal aortic wall were covered by thick neointima ($0.62{\pm}0.17mm$) without any endothelial lining. Transgraft cell migration at the normal aortic wall was more active than that at the aneurysmal aortic wall. Conclusion: Close contact between the stent and the graft, which was achieved with stent grafts with endo-exo-skeleton, could not enhance endothelial covering on the stent graft placed over the aneurysms.

Keywords

Acknowledgement

Supported by : Seoul National University Hospital

References

  1. Parodi JC, Palmaz JC, Barone HD. Transfemoral intraluminal graft implantation for abdominal aortic aneurysms. Ann Vasc Surg 1991;5:491-499 https://doi.org/10.1007/BF02015271
  2. Noishiki Y, Tomizawa Y, Yamane Y, Matsumoto A. The vicious cycle of nonhealing neointima in fabric vascular prostheses. Artif Organs 1995;19:7-16 https://doi.org/10.1111/j.1525-1594.1995.tb02238.x
  3. Berger K, Sauvage LR, Rao AM, Wood SJ. Healing of arterial prostheses in man: its incompleteness. Ann Surg 1972;175:118-127 https://doi.org/10.1097/00000658-197201000-00018
  4. Laborde JC, Parodi JC, Clem MF, Tio FO, Barone HD, Rivera FJ, et al. Intraluminal bypass of abdominal aortic aneurysm: feasibility study. Radiology 1992;184:185-190 https://doi.org/10.1148/radiology.184.1.1535160
  5. Dolmatch BL, Tio FO, Li XD, Dong YH. Patency and tissue response related to two types of polytetrafluoroethylene-covered stents in the dog. J Vasc Interv Radiol 1996;7:641-649 https://doi.org/10.1016/S1051-0443(96)70822-9
  6. Marty B, Leu AJ, Mucciolo A, von Segesser LK. Biologic fixation of polyester-versus polyurethane-covered stents in a porcine model. J Vasc Interv Radiol 2002;13:601-607 https://doi.org/10.1016/S1051-0443(07)61654-6
  7. Wilson EP, White RA, Kopchok GE, Donayre CE, de Virgilio C, Geselschap JH, et al. Deployment and healing of an ePTFE encapsulated stent endograft in the canine aorta. Ann Vasc Surg 1997;11:354-358 https://doi.org/10.1007/s100169900060
  8. Virmani R, Kolodgie FD, Dake MD, Silver JH, Jones RM, Jenkins M, et al. Histopathologic evaluation of an expanded polytetrafluoroethylene-nitinol stent endoprosthesis in canine iliofemoral arteries. J Vasc Interv Radiol 1999;10:445-456
  9. Boudghene F, Anidjar S, Allaire E, Osborne-Pellegrin M, Bigot JM, Michel JB. Endovascular grafting in elastase-induced experimental aortic aneurysms in dogs: feasibility and preliminary results. J Vasc Interv Radiol 1993;4:497-504 https://doi.org/10.1016/S1051-0443(93)71905-3
  10. Palmaz JC, Tio FO, Laborde JC, Clem M, Rivera FJ, Murphy KD, et al. Use of stents covered with polytetrafluoroethylene in experimental abdominal aortic aneurysm. J Vasc Interv Radiol 1995;6:879-885 https://doi.org/10.1016/S1051-0443(95)71207-6
  11. Benson AE, Palmaz JC, Tio FO, Sprague EA, Encarnacion CE, Josephs SC. Polytetrafluoroethylene-encapsulated stent-grafts: use in experimental abdominal aortic aneurysm. J Vasc Interv Radiol 1999;10:605-612 https://doi.org/10.1016/S1051-0443(99)70091-6
  12. Kim HB, Choi YH, So YH, Min SK, Kim HC, Kim YI, et al. Tissue responses to endovascular stent grafts for saccular abdominal aortic aneurysms in a canine model. J Korean Med Sci 2012;27:1170-1176 https://doi.org/10.3346/jkms.2012.27.10.1170
  13. Makutani S, Kichikawa K, Uchida H, Maeda M, Konishi N, Hiasa Y, et al. Effect of antithrombotic agents on the patency of PTFE-covered stents in the inferior vena cava: an experimental study. Cardiovasc Intervent Radiol 1999;22:232-238 https://doi.org/10.1007/s002709900373
  14. Ishii S, Sato M, Sonomura T, Yamada K, Tanihata H, Ishikawa H, et al. Optimal covering material for stent-grafts placed in the portal vein in a canine model. Cardiovasc Intervent Radiol 2005;28:624-631 https://doi.org/10.1007/s00270-004-0221-3
  15. Ombrellaro MP, Stevens SL, Kerstetter K, Freeman MB, Goldman MH. Healing characteristics of intraarterial stented grafts: effect of intraluminal position on prosthetic graft healing. Surgery 1996;120:60-70 https://doi.org/10.1016/S0039-6060(96)80242-X
  16. Hanel KC, McCabe C, Abbott WM, Fallon J, Megerman J. Current PTFE grafts: a biomechanical, scanning electron, and light microscopic evaluation. Ann Surg 1982;195:456-463 https://doi.org/10.1097/00000658-198204000-00012
  17. Briguori C, Sarais C, Sivieri G, Takagi T, Di Mario C, Colombo A. Polytetrafluoroethylene-covered stent and coronary artery aneurysms. Catheter Cardiovasc Interv 2002;55:326-330 https://doi.org/10.1002/ccd.10063
  18. Yip HK, Chen MC, Wu CJ, Hang CL, Hsieh KY, Fang CY, et al. Clinical features and outcome of coronary artery aneurysm in patients with acute myocardial infarction undergoing a primary percutaneous coronary intervention. Cardiology 2002;98:132-140 https://doi.org/10.1159/000066322

Cited by

  1. Histologic Analysis with the Newly Designed Exoskeleton Seal® Stent-Graft in the Porcine Abdominal Aorta vol.42, pp.9, 2014, https://doi.org/10.1007/s00270-019-02261-2