References
- Joshua, S. A., Dariush, K. A., and Yu, J. H., 2003, Future advanced windows for zero-energy homes, ASHRAE transactions Vol. 109, No. 2, pp. 871-882.
- Assimakopoulos, M. M., Tasngrassoulis, A., Santamouris, M., and Guarracino, G., 2007, Comparing the energy performance of an electrochromic window under various control strategies, Building and Environment, Vol. 42, No. 8, pp. 2829-2834. https://doi.org/10.1016/j.buildenv.2006.04.004
- Leigh, S. B. and Won, J. S., 2004, An analysis of demand for environmental controls on different residential building types, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 10, pp. 960-968.
- Kim, H. J., Park, J. S., Shin, U. C., and Yoon, J. H., 2008, Heating and cooling energy performance analysis of an office building according to SHGC level of the double and triple glazing with low-e coating, Proceedings of the KSES ʼ2008 Autumn Conference, pp. 90-95.
- Yoo, H. C., Oh, Y. H., and Park, S. K., 2005, The optimal window system of office buildings considering energy efficiency, Journal of the Korean Solar Energy Society, Vol. 25, No. 4, pp. 53-60.
- Park, Y. and Park, J. I., 2010, A study of energy use impacts by SHGCs of windows in detached house, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 22, No. 4, pp. 189-196.
- Jeong, S. H., Park, H. S., and Lee, B. Y., 2012, A study on analysis of energy consumption of detached house by U-value and SCs of window and building orientation, Journal of the Korean Solar Energy Society, Vol. 32, No. 3, pp. 96-103.
- Yoon, Y. S., Choi, W. K., and Sim, M. H., 2013, A study on the characteristics of the energy performance in curtain wall building-Focused on the glazing type, window to wall ratio and internal gains, Journal of the Architectural Institute of Korea, Vol. 29, No. 7, pp. 255-263.
- Lee, K. S., 2009, A guide to new technologies and energy performance, Kwangmoonkag, Seoul, pp. 139-149.
- Jang, Y. C., 2007, High efficiency window improved heat insulations, Magazine of SAREK, Vol. 36, No. 8, pp. 19-25.
- Jo, W. D., 1994, Development of checking program of architectural design for energy saving, KEMCO, pp. 57-67.
- Seok, H. T. and Kim, K. W., 2001, Thermal performance evaluation of design parameters and development of load prediction equation of office buildings, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 13, No. 9, pp. 914-921.
- Yoon, Y. S., Yoon, J. H., Choi, W. K., and Kwon, Y. C., 2012, A fundamental study on the optimal window applications according to the window ratio and SHGC in office buildings, Journal of KIAEBS, Vol. 6, No. 1, pp. 38-45.
- U.S. Department of ENERGY, http://apps1.eere.energy.gov/buildings/energ-yplus/weather_data.cfm.
- Lawrence berkeley national laboratory, 2006, DOE-2.2 manual Volume 4 : libraries and reports, California, pp. 22-25.
Cited by
- Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 vol.27, pp.7, 2015, https://doi.org/10.6110/KJACR.2015.27.7.380