DOI QR코드

DOI QR Code

중공비율에 따른 중공 프리캐스트 철근콘크리트 기둥의 압축거동

Compressive Behavior of Precast Concrete Column with Hollow Corresponding to Hollow Ratio

  • 이승준 (한국교통대학교 건축공학과) ;
  • 서수연 (한국교통대학교 건축공학과) ;
  • 배문용 (한국교통대학교 건축공학과) ;
  • 김강수 (서울시립대학교 건축학부)
  • Lee, Seung-Jun (Dept. of Architectural Engineering, Korea National University of Transportation) ;
  • Seo, Soo-Yeon (Dept. of Architectural Engineering, Korea National University of Transportation) ;
  • Pei, Wenlong (Dept. of Architectural Engineering, Korea National University of Transportation) ;
  • Kim, Kang-Su (Dept. of Architectural Engineering, University of Seoul)
  • 투고 : 2013.12.30
  • 심사 : 2014.03.12
  • 발행 : 2014.08.30

초록

최근 일련의 연구로부터, 중공이 있는 프리캐스트 콘크리트(hollewed precast concrete, HPC) 기둥를 사용할 경우, 일반적인 PC기둥에 비하여 접합부 콘크리트를 충실하게 채울수 있으며 이에 따라, 접합부의 고정도는 일체식 철근콘크리트(RC)와 같이 향상될 수 있음이 확인되었다. 그러나 충전콘크리트로 중공부가 채워진 후, HPC부재와 충전콘크리트의 강도가 서로 다르고 이 두 부재 사이에는 접촉면이 있음에 따라 합성구조와 같은 거동을 보이게 되며 이는 합성된 기둥의 구조적 거동과 강도에 영향을 미치게 된다. 이 논문에서는 HPC 기둥에서 중공의 크기와 중공부분 콘크리트의 채움 유무에 따른 기둥의 압축강도 시험을 실시하였다. 중공의 비율은 35, 50 그리고 59%이며 실험체의 양단을 단순지지 형태로서 지지한 뒤 중심압축력을 기둥의 상단에 작용시켰다. 또한 압축에 대한 HPC 기둥의 파괴거동을 묘사하기 위하여 유한요소 해석을 실시하였다. 실험 결과, 중공내부가 충전콘크리트로 채워진 기둥에서, PC와 충전콘크리트의 강도차이와 상관없이 중공률은 기둥의 초기강성에 영향을 미치지 않는 것으로 나타났다. 그러나 기둥의 압축강도는 중공률에 반비례하는 것으로 나타났다. 충전콘크리트가 채워지지 않은 HPC기둥의 구조성능은 중공의 직경에 밀접하게 관련이 있는 것으로 나타났으며, 특히, HPC의 두께가 지나치게 얇은 경우에는 국부적인 파괴가 전체 파괴를 지배하는 것으로 나타났다. 이러한 영향을 고려하여 HPC기둥의 압축내력을 산정할 수 있는 식을 제시하였다. 유한요소해석에서는, HPC와 충전콘크리트 사이의 접촉면을 고려할 경우, 해석 결과가 실험 결과와 좋은 대응을 보이는 것으로 나타났다.

From several researches, recently, it was found that using hollowed precast concrete (HPC) column made more compact concrete casting in joint region possible than using normal solid PC (Precast concrete) column. Therefore, the rigidity of joints can be improved like those of monolithic reinforced concrete (RC). After filling the hollow with grout concrete, however, it is expected that the HPC column behaviors like composite structure since PC element and grout concrete have different materials as well as there is a contact surface between two elements. These may affect the structural behavior and strength of the composite column. A compressive strength test was performed for the HPC column with parameter of hollow ratio for the case with and without grout in the hollow and the result is presented in this paper. The hollow ratios in the test are 35, 50 and 59% of whole section of column. Concentrated axial force was applied to top of the specimens supported as pin connection for both ends. In addition, finite element (FE) analysis was performed to simulate the failure behavior of HPC column for axial compression. As a result, it was found that the hollow ratio did not affect the initial stiffness of HPC filled with grout regardless of the strength difference of HPC and grout. However the strength was increased inversely corresponding to the hollow ratio. The structural capacity of HPC without grout closely related to the hollow size. Especially, the local collapse governs the overall failure when the thickness of HPC is too thin. Based on these effect, a suitable equation was suggested for calculation of the compressive strength of HPC column with or without grout. FE analysis considering the contact surface between HPC and grout produced a good result matched to the test result.

키워드

참고문헌

  1. Lee, J. M. and Choi. I. S., "Present and Future of Precast Concrete Structure," Architectural Institute of Korea, April, 2007, pp. 76-83.
  2. Kim, T. H., "Development of High Strength and Spun Concrete Column," Daelim Technology Review, 2012, pp. 132-136.
  3. Seo, S. Y., Yoon, S. J., and Lee, W. J., "Evaluation of Structural Performance of the Hollow PC Column Joint Subjected to Cyclic Lateral Load," Journal of the Korea Concrete Institute, Vol. 20, No. 3, 2008, pp. 335-343. https://doi.org/10.4334/JKCI.2008.20.3.335
  4. Korea "Concrete Design Code and Commentary," Kimoondang Publishing Company, Seoul, Korea, 2012. pp. 123-140.
  5. ACI, "Building Code Requirements for Reinforced Concrete (ACI 318M-11)," ACI Committee, American Concrete Institute, 2011, pp. 137-139.
  6. Midas IT, "MIDAS FEA Ver. 3.4.0 Manual," Manual of Midas IT, 2012, pp. 225-290.
  7. Vecchio, F. J. and Collins, M. P., "The Modified Compression Field Theory for Reinforced Concrete Elements Subjected to Shear," ACI Journal, Vol. 83, No. 22 1986, pp. 219-231. (doi: http://10.14359/10416)
  8. Selby, R. G. and Vecchio, F. J., "Three-Dimensional Constitutive Relations for Reinforced Concrete," Report No. 93-02, Department, of Civil Engineering, University of Toronto, 1993, pp. 124-147.