DOI QR코드

DOI QR Code

Flow Simulation of Chamber System to Obtain Particle Uniformity and Study on Bio-aerosol Reduction Test

입자 균등성 확보를 위한 시험 챔버의 유동 시뮬레이션 및 이를 이용한 기상 부유균 저감 특성의 실험적 연구

  • Park, Dae-Hoon (Department of Mechanical Engineering, Yonsei University) ;
  • Hyun, Junho (Graduate Program in Clean Technology, Yonsei University) ;
  • Hwang, Jungho (Department of Mechanical Engineering, Yonsei University)
  • 박대훈 (연세대학교 기계공학과) ;
  • 현준호 (연세대학교 청정공학협동과정) ;
  • 황정호 (연세대학교 기계공학과)
  • Received : 2014.06.05
  • Accepted : 2014.06.25
  • Published : 2014.06.30

Abstract

Since airborne bacteria have been known to aggravate indoor air quality, studies on reducing bacteria particles increase recently. In this study, a chamber(0.8m x 0.8m x 1.56m) system was built in order to simulate real conditions for reducing airborne bacteria, and evaluated by a simple aerosol reduction test. A method utilizing CFD(Computational Fluid Dynamics) simulation was used to detect the horizontal cross-sectional area which represents particle distribution in the chamber. Then an air-cleaner with HEPA filter and Carbon Fiber Ionizer was located on that area for aerosol reduction test. The CFD result found the area was located at 0.2m height from the bottom of the chamber, and the test showed aerosol reduction efficiencies using measurements of number concentration and CFU(colony forming unit) per each case. At the measurement of number concentration, the reduction efficiency of air-cleaner with filter and ionizer(Case 3) was about 90% after 4 minutes from the stop of the bacteria injection, and that with only filter(Case 2) was about 90% after 8 minutes from the beginning. Lastly, that without filter and ionizer(Case 1) was about 30% after 10 minutes. At the measurement of CFU, it shows similar results but it is related to viability of bio-aerosol.

Keywords

References

  1. Fischer, G., Schwalbe, R., MÖller, M., Osrowski, R. and Dott, W. (1999) Species-specific production of microbial volatile organic compounds(MVOC) by airborne fungi from a compost facility, Chemosphere, 39(5), 795-810. https://doi.org/10.1016/S0045-6535(99)00015-6
  2. Hong, S.K., Jung, Y.T., Chun, J., Paik, S.Y. (2003) Isolation and Identification of Bacteria from Air conditioners and its Hygiene, The Korean Journal of Microbiology, 39(4), 283-287.
  3. Kim, D.Y., Yoon, K.Y., Park, J.H., Kim, Y.S., Hwang, J. (2010) Application of Carbon Fiber Ionizer for Increasing Antimicrobial Efficacy in a Small-scale Commercial Air Indoor, Journal of Korean Society for Indoor Environment, 7(2), 77-88.
  4. Kim, Y.S. (1995) Health effect of indoor air pollution, SAREK Magazine and ASHRAE Journal, 24(1), 29-32.
  5. Menetrez, M.Y., and Foarde, K.K. (2002) Microbial volatile organic compound emission rates and exposure model, Indoor and Built Environment, 11(4), 208-213. https://doi.org/10.1177/1420326X0201100405
  6. Yoon, K.Y., Kim, Y.S., Park, J.H., Hwang, J. (2008) Characteristics of Commercial Antimicrobial Filter Media for Removal of Bioaerosols, Journal of Korean Society for Indoor Environment, 5(4), 329-337.