References
- Jarritt PH et al., "Use of Combined PET/CT Images for Radiotherapy Planning: Initial Experiences in Lung Cancer," BIR, Vol. Suppl. 28, No. 1, pp.33-40, 2005.
- Yang W et al., "Adequacy of Inhale/Exhale Breathhold CT Based ITV Margins and Image-Guided Registration for Free-Breathing Pancreas and Liver SBRT." Radiat Oncol, Vol. 9, No.11, 2014.
- Smyth G et al., "A Dose Distribution Overlay Technique for Image Guidance During Prostate Radiotherapy." BIR, Vol. 81, Issue. 971, pp. 890-896, 2008.
- Wu WC et al., "A Study on The Influence of Breathing Phases In Intensity-Modulated Radiotherapy of Lung Tumours Using Four-Dimensional CT." BIR, Vol. 83, Issue. 987, pp. 252-256, 2010.
- Kim YJ et al., "A Comparison Between Three Dimensional Radiation Therapy and Intensity Modulated Tadiation Yherapy on Prostate Cancer" Journal of the Korean Society of Radiology, Vol. 7, No. 6, pp. 409-414, 2013. https://doi.org/10.7742/jksr.2013.7.6.409
- Chris C, James C. Harrington, and Larry A DeWerd. "An Electron Density Calibration Phantom for CT-Based Treatment Planning Computers." Medical physics, Vol. 19, No. 2, pp. 325-327, 1992. https://doi.org/10.1118/1.596862
- Schneider Uwe Eros Pedroni and Antony Lomax. "The Calibration of CT Hounsfield Units for Radiotherapy Treatment Planning." Phys. Med. Biod, Vol. 41, No.1, pp.111-124, 1996. https://doi.org/10.1088/0031-9155/41/1/009
- Thomas SJ. "Relative Electron Density Calibration of CT Scanners for Radiotherapy Treatment Planning." BIR, Vol. 72, Issue. 860, pp.781-786, 1999.
- Tsukihara, Masayoshi et al., "Conversion of The Energy-Subtracted CT Number to Electron Density Based on A Aingle Linear Relationship: An Experimental Verification Using A Clinical Dual-Source CT Scanner." Phys. Med. Biol, Vol. 58, No. 9, pp.135-144, 2013. https://doi.org/10.1088/0031-9155/58/9/N135
- Skrzy-ski, Witold et al., "Computed Tomography As A Source of Electron Density Information For Radiation Treatment Planning." Strahlentherapie und Onkologie, Vol. 186, No. 6, pp.327-333, 2010. https://doi.org/10.1007/s00066-010-2086-5
- Yohannes, Indra et al., "A Formulation of Tissue-And Water-Equivalent Materials Using The Stoichiometric Analysis Method for CT-Number Calibration In Radiotherapy Treatment Planning." Phys. Med. Biol, Vol. 57, No. 5, pp.1173-1190, 2012. https://doi.org/10.1088/0031-9155/57/5/1173
- Hounsfield GN. "Picture Quality of Computed Tomography." AJR, Vol. 127, No. 1, pp.3-9, 1976. https://doi.org/10.2214/ajr.127.1.3
- AAPM Report 1. "Phantoms for Performance Evaluation and Quality Assurance of CT Scanners." Medical Physics Publishing, 1977.
- AAPM Report 60. "Instrumentation Requirements of Diagnostic Radiological Physicists." Medical Physics Publishing, 1998.
- Barrett, Julia F, and Nicholas Keat. "Artifacts in CT: Recognition and Avoidance1." Radiographics, Vol. 24, No. 6, pp.1679-1691, 2004. https://doi.org/10.1148/rg.246045065
- Kalender, Willi A, Robert Hebel, and Johannes Ebersberger. "Reduction of CT Artifacts Caused by Metallic Implants." Radiology, Vol. 164, No. 2, pp.576-577, 1987. https://doi.org/10.1148/radiology.164.2.3602406
- Glover, Gary H, and Norbert JP. "An Algorithm for The Reduction of Metal Clip Artifacts in CT Reconstructions." Medical physics, Vol. 8, No. 6, pp.799-807, 1981. https://doi.org/10.1118/1.595032
- Wang G et al., "Iterative Deblurring for CT Metal Artifact Reduction." IEEE Transactions on Medical Imaging , Vol. 15, No. 5, pp.657-664, 1996. https://doi.org/10.1109/42.538943
- Robertson, Douglas D et al., "Total Hip Prosthesis Metal-Artifact Suppression Using Iterative Deblurring Reconstruction." Journal of computer assisted tomography, Vol. 21, No. 2, pp.293-298, 1997. https://doi.org/10.1097/00004728-199703000-00024
- Zhao, Shiying et al., "X-ray CT Metal artifact Reduction Using Wavelets: An Application for Imaging Total Hip Prostheses." IEEE Transactions on Medical Imaging, Vol. 19, No. 12, pp.1238-1247, 2000. https://doi.org/10.1109/42.897816
- Watzke, Oliver, and Willi AK. "A Pragmatic Approach to Metal Artifact Reduction in CT: Merging of Metal Artifact Reduced Images." European radiology, Vol. 14, No. 5, pp.849-856, 2004. https://doi.org/10.1007/s00330-004-2263-y
- Zhuge Y et al., "SU-E-I-51: Metal Artifact Reduction in CT Using Deformable Tissue-Class Modeling." Medical Physics, Vol. 40, No. 6, pp.136-137, 2013.
- Glide-Hurst C et al., "Changes Realized from Extended Bit-Depth and Metal Artifact Reduction in CT." Medical physics, Vol. 40, No. 6, pp.061711, 2013. https://doi.org/10.1118/1.4805102
- Kidoh M et al., "Reduction of Dental Metallic Artefacts in CT: Value of A Newly Developed Algorithm for Metal Artifact Reduction (O-MAR)." Clinical radiology, Vol. 69, No. 1, pp. e11-e16, 2014. https://doi.org/10.1016/j.crad.2013.08.008
- Hilgers, Guido, Tonnis Nuver, and Andre Minken. "The CT Number Accuracy of a Novel Commercial Metal Artifact Reduction Algorithm for Large Orthopedic Implants." Journal of Applied Clinical Medical Physics, Vol. 15, No. 1, pp.274-278, 2014. https://doi.org/10.1120/jacmp.v15i1.4597
- Hounsfield GN. "Computerized Transverse Axial Scanning (Tomography): Part I. Description of System." British Journal of Radiology, Vol. 45, pp.1016-1022, 1973.
- Constantinou, Chris, James C. Harrington, and Larry A DeWerd. "An Electron Density Calibration Phantom for CT-Based Treatment Planning Computers." Medical physics, Vol. 19, No. 2, pp.325-327, 1992. https://doi.org/10.1118/1.596862
- Philips CT Clinical Science: Metal Artifact Reduction for Orthopedic Implants (O-MAR), white paper [Internet]. Andover, MA: Philips Healthcare USA; 2012. [cited 2013 Jun 26]. Available from: http://clinical.netforum.healthcare.philips.com/us_en/Explore/White-Papers/CT/Metal-Artifact-Reductionfor-Orthopedic-Implants-(O-MAR)
- Bazalova, Magdalena et al., "Correction of CT Artifacts and Its Influence on Monte Carlo Dose Calculations." Medical physics, Vol. 34, No. 6, pp.2119-2132, 2007. https://doi.org/10.1118/1.2736777
Cited by
- 고밀도 인공물 환자에서 반복적 재구성 사용 유무에 따른 3차원 입체조형 방사선 치료 계획 인자의 정량분석 vol.14, pp.1, 2014, https://doi.org/10.7742/jksr.2020.14.1.7