DOI QR코드

DOI QR Code

Stiffener configurations of beam to concrete-filled tube column connections

  • Dessouki, Abdelrahim K. (Structural Engineering Department, Faculty of Engineering, Ain Shams University) ;
  • Yousef, Ahmed H. (Structural Engineering Department, Faculty of Engineering, Ain Shams University) ;
  • Fawzy, Mona M. (Structural Engineering Department, Faculty of Engineering, Ain Shams University)
  • Received : 2013.10.16
  • Accepted : 2014.02.21
  • Published : 2014.07.25

Abstract

The objective of this research is to study the ultimate moment capacity of the connections between steel I-beams and concrete-filled steel tube columns using different stiffener configurations. The main parameters considered are column cross section shape, square or circular, and filling the column with concrete. This analytical study includes finite element models using ANSYS program taking geometric and material nonlinearities into consideration. These models are verified against the experimental results obtained from previous researches and current design guides. The results show that using proper stiffener configuration affects the stress distribution through the connection and increases the ultimate moment capacity of the connections. Also, circular column is advantageous than the square column for all stiffener configurations and dimensions.

Keywords

References

  1. AIJ (1990), Recommendations for the Design and Fabrication of Tubular Structures in Steel, (3rd Edition), Architectural Institute of Japan, Tokyo, Japan.
  2. ANSYS (2009), Finite Element Program, Swanson Analysis System Inc., Release 12.1.
  3. Azizinamini, A. (2005), "Design of through beam connection detail for connecting steel beam to circular concrete-filled steel tube columns", Steel Struct., 5, 349-356.
  4. Ellobody, E. and Young, B. (2006), "Nonlinear analysis of concrete-filled steel SHS and RHS columns", Thin-Wall. Struct., 44(8), 919-930. https://doi.org/10.1016/j.tws.2006.07.005
  5. Elremaily, A. and Azizinamini, A. (2001), "Experimental behavior of steel beam to CFT column connections", J. Constructi. Steel Res., 57(10), 1099-1119. https://doi.org/10.1016/S0143-974X(01)00025-6
  6. ECP No. (205) (2001), "Egyptian Code of Practice for Steel Construction and Bridges", Allowable Stress Design (ASD).
  7. Fawzy, M.M. (2013), "Moment connections of beams and concrete-filled steel columns", Ph.D. Thesis, Faculty of Engineering, Ain Shams University, Egypt.
  8. Fukumoto, T. (2005), "Steel beam to concrete-filled steel tube column, moment connections in Japan", Steel Struct., 5, 357-365.
  9. Gere, J.M. and Timoshenko, S.P. (1997), "Mechanics of Materials", PWS Publishing Company, Boston, MA, USA.
  10. Ju, Y.K., Kim, Y. and Kim, S. (2004), "FEM analysis on structural behavior of CFT column to flat plate slab connection", Report, University of Texas, Austin, TX, USA.
  11. Kim, Y., Shin, K. and Kim, W. (2008), "Effect of stiffener details on behavior of CFT column-to-beam connections", Steel Struct., 8, 119-133.
  12. Kimura, K., Chung, J., Matsui, C. and Choi, S. (2005), "Structural characteristics of H-shaped beam-to-square tube column connection with vertical stiffeners", Int. J. Steel Struct., KSSC, 5(2), 109-117.
  13. Kurobane, Y., Packer, J.A., Wardenier, J. and Yeomans, N. (2004), "Design guide for structural hollow section column connections", CIDECT, 9.
  14. Lu, L.H. (1997), "The static strength of I-beam to rectangular hollow section column connections", Ph.D. Thesis, Faculty of Civil Engineering and Geosciences, Delft University of Technology, Netherlands.
  15. Shin, K., Kim, Y., Oh, Y. and Moon, T. (2004), "Behavior of welded CFT column to H-beam connections with external stiffeners", Eng. Struct., 26(13), 1877-1887. https://doi.org/10.1016/j.engstruct.2004.06.016
  16. Wang, W., Han, L. and Uy, B. (2008), "Experimental behaviour of steel reduced beam section to concrete-filled circular hollow section column connections", J. Construct. Steel Res., 64(5), 493-504. https://doi.org/10.1016/j.jcsr.2007.10.005
  17. Wang, J., Han, L. and Uy, B. (2009), "Behaviour of flush end plate joints to concrete-filled steel tubular columns", J. Construct. Steel Res., 65(4), 925-939. https://doi.org/10.1016/j.jcsr.2008.10.010
  18. Wang, Y., Xuan, Y. and Mao, P. (2010), "Nonlinear finite element analysis of the steel-concrete composite beam to concrete-filled steel tubular column joints", Int. J. Nonlinear Sci., 9 (3), 341-348.
  19. Winkel, G.D. (1998), "The static strength of I-beam to circular hollow section column connections", Ph.D. Thesis, Faculty of Civil Engineering and Geosciences, Delft University of Technology, Netherlands.
  20. Yao, H., Goldsworthy, H. and Gad, E. (2008), "Experimental and numerical investigation of the tensile behavior of blind-bolted T-stub connections to concrete-filled circular columns", J. Struct. Eng., ASCE, 134(2), 198-208. https://doi.org/10.1061/(ASCE)0733-9445(2008)134:2(198)

Cited by

  1. Numerical study of internally reinforced circular CFT column-to-foundation connection according to design variables vol.23, pp.4, 2014, https://doi.org/10.12989/scs.2017.23.4.445
  2. AN INVESTIGATION INTO WORKING BEHAVIOR CHARACTERISTICS OF PARABOLIC CFST ARCHES APPLYING STRUCTURAL STRESSING STATE THEORY vol.25, pp.3, 2014, https://doi.org/10.3846/jcem.2019.8102